KDFD068W KDFDPDEV: RMF SYNCHRONIZATION FAILED - RC=n - RECORDING INTERVAL DEFAULTING TO 15 MINUTES
Explanation
Module KDFDPDEV has not been able to synchronize recording with the RMF™ interval. RC=n indicates the reason that the recording interval defaulted to 15 minutes. Return codes are:
- 0 - OK
- 4 - Interval=0 from API
- 8 - NO STGST address
- 12 - NO RMF routine address
- 16 - Parm area address in R1=0 on entry
- 20 - RMF Routine address is dummy
- 24 - Interval = 0 from control blocks
- 28 - Interval less than 1 minute
- 32 - Load failed for KDFDRMFI
- 36 - KDFDRMFI entry point not found
System action
Device statistics are collected at 15-minute intervals.
User response
The destination is the Tivoli® Enterprise Monitoring Server Engine log file, RKLVLOG. If this message persists and RMF monitor 1 is active contact IBM® Software Support with the return code information.