MEXIP05

Use this procedure to isolate the problem when a duplicate expansion drawer is detected.

Procedure

  1. Is a location code in the format Un-Px-Cy or Un-Px-Cy-Cz available in the serviceable event view for the reference code you are working on?
    • Yes: Continue with the next step.
    • No: Contact your next level of support. This ends the procedure.
  2. Use the location code to find the PCIe3 cable adapter. For information about locations, see Part locations and location codes. Trace the expansion drawer cables from the PCIe3 cable adapter to the I/O module in an EMX0 PCIe3 expansion drawer. Ensure that both expansion drawer cables are connected to the correct I/O module of the EMX0 PCIe3 expansion drawer and ensure proper seating of both expansion drawer cables at the I/O module ports. Were any problems detected with the expansion drawer cables?
    • Yes: If any expansion drawer cables are not properly located or seated, reroute or reseat the expansion drawer cables. Then, use procedure MEXIP06 to recover the EMX0 PCIe3 expansion drawer. This ends the procedure.
    • No: Continue with the next failing item in the failing item list of the serviceable event. This ends the procedure.