SASCABL

The SAS device cable might be failing.

Use the following table to determine the SAS device cables that might be failing. Ensure that the cables are connected correctly. If they are not connected correctly, fix the cable connection problem. If they are already connected correctly, replace the cables. See "Planning for serial-attached SCSI cables," in Planning for cables for cable FRU part numbers.
Notes:
  • Power off the system, partition, or card slot before connecting and disconnecting cables, to prevent hardware damage.
  • HD SAS cables have a key that prevents the cable retention from latching if the cable is oriented incorrectly. Ensure that the HD SAS cables are inserted with the blue release tab on the right side of the card connector and latch correctly.
Table 1. SAS device cables for system units and expansion units
System unit or expansion unit SAS device cables
5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S Front SAS cable for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S.
Disk expansion unit attached to a 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S
9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S Front SAS cable for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S.
Disk expansion unit attached to a 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S
This ends the procedure.