Placing an 8408-44E or 8408-E8E system into the operating position

Use this procedure to place an 8408-44E or 8408-E8E system into the operating position.

Note: When you place the system in the operating position, ensure that the cables at the rear of the system do not catch or bind as you push the system unit back into the rack.
To place an 8408-44E or 8408-E8E system in the operating position, complete the following steps:
  1. Ensure that you have the electrostatic discharge (ESD) wrist strap attached. If not, attach it now.
  2. Unlock the blue rail safety latches (A) by lifting them upward.
  3. Push the system unit (B) back into the rack until both system unit release latches lock into position.
    Note: Slide the system unit slowly into the rack to ensure that your fingers do not get caught in the side rails.
    Figure 1. Placing the system into the operating position
    Placing the system into the operating position
  4. Secure the server to the rack by using shipping screws.
  5. If you have not already done so, replace the front cover. For instructions, see Installing the front cover on an 8408-44E or 8408-E8E system.



Last updated: Thu, October 12, 2017