TWRCARD

An SPCN card might be failing.

For more information about failing part numbers, location codes, or removal and replacement procedures, see Part locations and location codes. Select your machine type and model number to see applicable procedures for your system.

The SPCN card can be on either an adapter style card or integrated on the system backplane or an I/O backplane in an attached EMX0 PCIe3 expansion drawer.

Complete the following steps:

  1. Is the system reference code (SRC) 1xxx00AD?
    • No: Continue with the next step.
    • Yes: The 1xxx00AD SRC might be caused by an intentional reset of the service processor. An intentional reset is caused by an action such as a pin hole reset, ASMI menu selection, or part replacement. An intentional reset requires no service action. If your system produced the 1xxx00AD SRC and an intentional reset was not the cause, use the following table to determine the part number of the field-replaceable unit (FRU). This ends the procedure.
      Type and model Part number Description Location code
      5148-21L, 5148-22L, 8247-21L, 8247-22L, 8247-42L, 8284-21A, 8284-22A, 8286-41A, or 8286-42A See System parts. System backplane Un-P1
      8408-44E or 8408-E8E See System parts. Service processor card Un-P1-C5
      9080-MHE, 9080-MME, 9119-MHE, or 9119-MME See System parts. Service processor card Un-P1-C7 or Un-P1-C10 in the system control unit
  2. The failing SPCN component is in an EMX0 PCIe3 expansion drawer. Use the following table to determine the part number of the field-replaceable unit (FRU).
    Type and model Part number Description Location code
    EMX0 PCIe3 expansion drawer See System parts. Chassis management card Un-P3-C1
    This ends the procedure.



Last updated: Tue, April 21, 2020