OVERTMP
The system detected a warning or fault due to an over temperature condition.
For more information about failing part numbers, location codes, or removal and replacement procedures, see Part locations and location codes. Select your machine type and model number to see applicable procedures for your system.
- Is the room temperature less than 35°C (95°F)?
- Yes: Continue with the next step.
- No: Notify the customer. The customer must bring the room temperature within normal range. Continue with the next step.
- Are the system front and rear doors free of obstructions?
- Yes: Continue with the next step.
- No: Notify the customer. The system must be free of obstructions for proper air flow. Continue with the next step.
- Is the system an 8247-22L or 8284-22A with
water-cooled processors?
- Yes: Continue with the next step.
- No: Continue with step 5.
- Go to Water cooling system specification and requirements. Are all
of the requirements for water-cooled systems met?
- Yes: Continue with the next step.
- No: Work with the customer to ensure that all of the requirements for water-cooled systems are met. This ends the procedure.
- If applicable, do all the positions in the processor subsystem contain
processors or fillers?
- Yes: Continue with the next step.
- No: Fill any open positions with processors or fillers. This ends the procedure.
- Do all the power supply positions contain power supplies or fillers?
- Yes: Continue with the next step.
- No: Fill any open positions with supplies or fan books. This ends the procedure.
- Are you working with reference code 11007201 or has reference
code 11007201 been logged?
- Yes: The room temperature is too high. The customer must bring the room temperature to less than 35°C (95°F). If the room temperature is less than 35°C (95°F), continue with the next step.
- No: Replace the failing item that is listed in the serviceable event view for the reference code you are working with and go to step 9.
- Replace the control panel. Use the following table to determine the part number for the failing
item. Then, continue with the next step.
CCIN or FFC Type and model Part number Description Location code Any See System parts. Control (operator) panel Un-D1 - After each failing item is replaced, is the reference code that sent you to
this procedure still reported?
- Yes: Replace the next failing item in the failing item list. If all of the failing items in the failing item list have been replaced, contact your next level of support. This ends the procedure.
- No: The problem has been corrected. This ends the procedure.