FSPSP32

A problem with the enclosure has been found.

The problem might be caused by one of the following items:

See System FRU locations for instructions for removing and replacing FRUs.

Perform the following steps:

  1. Record the reason code (the last 4 characters of word 11) from the SRC by looking at the operator panel or accessing the error log with the ASMI.
  2. Is the reason code A46F?
    • No: Go to step 5.
    • Yes: Continue with the next step.
  3. Check for and apply any server firmware updates. Does the problem persist?
    • No: This ends the procedure.
    • Yes: Continue with the next step.
  4. Use the following table to determine the action to perform.
    System Action

    8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, 8205-E6D, 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, 8268-E1D

    Perform the following steps:
    1. Power off the system. See Powering on and powering off the system .
    2. Replace the system backplane (Un-P1).
    3. Power on the system to the hypervisor standby.
      Note: Slow boot is not supported.

      Does the problem persist?

      No:
      This ends the procedure.
      Yes:
      Contact your next level of support. This ends the procedure.
    8233-E8B, 8236-E8C Perform the following steps:
    1. Power off the system. See Powering on and powering off the system .
    2. Replace the system backplane (Un-P1).
    3. Determine the level of firmware the system is running.

      Is system firmware AL710_xxx installed?

      Does the problem persist?

      No:
      This ends the procedure.
      Yes:
      Contact your next level of support. This ends the procedure.
    8248-L4T, 8408-E8D, 9109-RMD Perform the following steps:
    1. Power off the system. See Powering on and powering off the system .
    2. Replace the service processor card at location Un-P1-C1.
    3. Power on the system to the hypervisor standby.
      Note: Slow boot is not supported.

      Does the problem persist?

      No:
      This ends the procedure.
      Yes:
      Contact your next level of support. This ends the procedure.

    8412-EAD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, or 9179-MHD

    Perform the following steps:
    1. Power off the system. See Powering on and powering off the system .
    2. Replace the service processor (Un-P1-C1).
    3. Determine the level of firmware the system is running.

      Is system firmware AM710_xxx installed?

      Does the problem persist?

      No:
      This ends the procedure.
      Yes:
      Continue with the next step.
    4. Power off the system. See Powering on and powering off the system .
    5. Replace the system backplane.
    6. Determine the level of firmware the system is running.

      Is system firmware AM710_xxx installed?

      Does the problem persist?

      No:
      This ends the procedure.
      Yes:
      Contact your next level of support. This ends the procedure.
    9119-FHB Perform the following steps:
    1. Power off the system. See Powering on and powering off the system .
    2. Replace both system controller cards (Un-P1-C2 and Un-P1-C5).
    3. Power on the system to the hypervisor standby.
      Note: Slow boot is not supported.

      Does the problem persist?

      No:
      This ends the procedure.
      Yes:
      Continue with the next step.
    4. Power off the system. See Powering on and powering off the system .
    5. Replace the midplane (Un-P1).
    6. Power on the system to the hypervisor standby.
      Note: Slow boot is not supported.

      Does the problem persist?

      No:
      This ends the procedure.
      Yes:
      Contact your next level of support. This ends the procedure.
    9125-F2C Perform the following steps:
    1. Power off the system. See Powering on and powering off the system .
    2. Replace both of the DCCAs (locations Un-P1-C147 and Un-P1-C148).
    3. Power on the system to the hypervisor standby.
      Note: Slow boot is not supported.

      Does the problem persist?

      No:
      This ends the procedure.
      Yes:
      Continue with the next step.
    4. Power off the system. See Powering on and powering off the system .
    5. Replace the system backplane at location Un-P1.
    6. Power on the system to the hypervisor standby.
      Note: Slow boot is not supported.

      Does the problem persist?

      No:
      This ends the procedure.
      Yes:
      Contact your next level of support. This ends the procedure.
  5. Is the reason code A41C or A460?
    • No: Go to step 7.
    • Yes: Continue with the next step.
  6. Perform the following steps:
    1. Set the enclosure serial number using the ASMI. See Setting the system enclosure type.
      Note: The enclosure serial number can be found on the label located on the system chassis.
    2. The service processor will automatically reset when leaving the ASMI after updating the serial number.
    3. To determine the action to perform, use the following table.

      System:

      Action:

      8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, 8205-E6D, 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, 8248-L4T, 8268-E1D, 8408-E8D, 9109-RMD, 9119-FHB, 9125-F2C

      Power on the system to the hypervisor standby.
      Note: Slow boot is not supported.

      8233-E8B, 8236-E8C

      Determine the level of firmware the system is running.

      Is system firmware AL710_xxx installed?

      8412-EAD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, or 9179-MHD

      Determine the level of firmware the system is running.

      Is system firmware AM710_xxx installed?

    Does the problem persist?

    • No: This ends the procedure.
    • Yes: Contact your next level of support. This ends the procedure.
  7. Is the reason code A45F?
    • No: Contact your next level of support. This ends the procedure.
    • Yes: Continue with the next step.
  8. Perform the following steps:
    1. Set the enclosure feature code using the ASMI. See Setting the system enclosure type. The service processor will automatically reset when leaving the ASMI after updating the serial number.
    2. To determine the action to perform, use the following table.

      System:

      Action:

      8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, 8205-E6D, 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, 8248-L4T, 8268-E1D, 8408-E8D, 9109-RMD, 9119-FHB, 9125-F2C

      Power on the system to the hypervisor standby.
      Note: Slow boot is not supported.

      8233-E8B, 8236-E8C

      Determine the level of firmware the system is running.

      Is system firmware AL710_xxx installed?

      8412-EAD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, or 9179-MHD

      Determine the level of firmware the system is running.

      Is system firmware AM710_xxx installed?

    Does the problem persist?

    • No: This ends the procedure.
    • Yes: Contact your next level of support. This ends the procedure.