Use this procedure to replace an existing Redundant Array
of Independent Disks (RAID)/cache enablement card.
You must have already completed the procedure Removing the 8231-E2B RAID/cache
enablement card.
To replace a RAID/cache enablement
card, complete the following steps:
- Locate the slot for the RAID/cache enablement card.
- Align the RAID/cache enablement card with the slot in the
system.
- Slide the RAID/cache enablement card fully into the system
until the tab (A) locks into place.
Figure 1. RAID/cache enablement card replacement
in a rack-mounted system unit
- Replace the service access cover. For instructions, see Installing
the service access cover for the system.
- For a rack-mounted system, put the system into the operating
position. For instructions, see Placing the rack-mounted system
into the operating position.
- Reconnect the power source.
- Start the system. For instructions, see Starting a system or logical partition.
- Verify the installed part or repair.
- If you replaced the part because of a service action,
verify the installed part. For instructions, see Verifying a repair.
- If you installed the part for any other reason, verify the installed
part. For instructions, see Verifying the installed part.