With a service request number (SRN) obtained from error log analysis or from the AIX® error log, use the following table to determine which maintenance analysis procedures (MAPs) to use.
The following table includes only SRNs that are associated with the MAPs contained in this document.
| SRN | Description | MAP |
|---|---|---|
| nnnn-101 | Controller configuration error | MAP 210 – replace controller |
nnnn-710 |
Controller failure | MAP 210 – replace controller |
| nnnn-720 | Controller device bus configuration error | |
| nnnn-102E | Out of alternate disk storage for storage | MAP 210 – replace disk |
| nnnn-3002 | Addressed device failed to respond to selection | MAP 210 – replace device |
| nnnn-3010 | Disk returned wrong response to controller | MAP 210 – replace disk |
nnnn-3020 |
Various errors requiring SAS fabric problem isolation | |
| nnnn-4010 | Configuration error, incorrect connection between cascaded enclosures | MAP 3142 for a PCI-X or PCIe controller or MAP 3242 for a PCIe2 or a PCIe3 controller |
| nnnn-4020 | Configuration error, connections exceed controller design limits | MAP 3143 for a PCI-X or PCIe controller or MAP 3243 for a PCIe2 or a PCIe3 controller |
| nnnn-4030 | Configuration error, incorrect multipath connection | |
| nnnn-4040 | Configuration error, incomplete multipath connection between controller and enclosure detected | |
| nnnn-4041 | Configuration error, incomplete multipath connection between enclosures and device detected | MAP 3146 for a PCI-X or PCIe controller or MAP 3246 for a PCIe2 or a PCIe3 controller |
| nnnn-4050 | Attached enclosure does not support required multipath function | MAP 3148 for a PCI-X or PCIe controller or MAP 3248 for a PCIe2 or a PCIe3 controller |
| nnnn-4060 | Multipath redundancy level got worse | |
| nnnn-4080 | Thermal error, controller exceeded maximum operating temperature | MAP 3295 for a PCIe2 or a PCIe3 controller |
| nnnn-4085 | Please contact your next level of support or service provider | MAP 3290 for a PCIe2 or a PCIe3 controller |
| nnnn-4100 | Device bus fabric error | |
| nnnn-4101 | Temporary device bus fabric error | |
| nnnn-4102 | Device bus fabric performance degradation | MAP 3254 for a PCIe2 or a PCIe3 controller |
| nnnn-4110 | Unsupported enclosure function detected | MAP 3145 or a PCI-X or PCIe controller or MAP 3245 for a PCIe2 or a PCIe3 controller |
| nnnn-4120 | Configuration error, cable VPD cannot be read | MAP 3261 for a PCIe2 controller |
| nnnn-4121 | Configuration error, required cable is missing | MAP 3261 for a PCIe2 or a PCIe3 controller |
| nnnn-4123 | Configuration error, invalid cable Vital Product Data | MAP 3261 for a PCIe2 controller |
nnnn-4150 |
PCI Bus error detected by controller | MAP 210 – replace controller, if the problem is not fixed, replace the planar or backplane |
| nnnn-4170 | Controller T10 DIF host bus error | MAP 3260 for a PCIe2 or a PCIe3 controller |
| nnnn-4171 | Controller recovered T10 DIF host bus error | MAP 3260 for a PCIe2 or a PCIe3 controller |
| nnnn-7001 | Temporary disk data error | MAP 210 – replace disk |
nnnn-8008 |
A permanent cache battery pack failure occurred |
MAP 3100 for a PCI-X or PCIe controller |
nnnn-8150 |
Controller Failure | MAP 210 – replace controller |
nnnn-9000 |
Controller detected device error during configuration discovery | MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller |
| nnnn-9008 | Controller does not support function expected for one or more disk | MAP 3130 for a PCI-X or PCIe controller or MAP 3230 for a PCIe2 or a PCIe3 controller |
| nnnn-9010 | Cache data associated with attached disks cannot be found | MAP 3120 for a PCI-X or PCIe controller or MAP 3220 for a PCIe2 or a PCIe3 controller |
| nnnn-9011 | Cache data belongs to disks other than those attached | MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller |
nnnn-9020 |
Two or more disks are missing from a RAID 5 or RAID 6 Disk Array | MAP 3111 for a PCI-X or PCIe controller or MAP 3211 for a PCIe2 or a PCIe3 controller |
| nnnn-9023 | One or more disk array members are not at required physical locations | MAP 3112 for a PCI-X or PCIe controller or MAP 3212 for a PCIe2 or a PCIe3 controller |
| nnnn-9024 | Physical location of disk array members conflict with another disk array | MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller |
| nnnn-9025 | Incompatible disk installed at degraded disk location in disk array | MAP 3110 for a PCI-X or PCIe controller or MAP 3210 for a PCIe2 or a PCIe3 controller |
| nnnn-9026 | Previously degraded disk in disk array not found at required physical location | MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller |
| nnnn-9027 | Disk array is or would become degraded and parity data is out of synchronization | MAP 3113 for a PCI-X or PCIe controller or MAP 3213 for a PCIe2 or a PCIe3 controller |
| nnnn-9028 | Maximum number of functional disk arrays has been exceeded | MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller |
| nnnn-9029 | Maximum number of functional disk array disks has been exceeded | MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller |
| nnnn-9030 | Disk array is degraded due to missing/failed disk | MAP 3110 for a PCI-X or PCIe controller or MAP 3210 for a PCIe2 or a PCIe3 controller |
| nnnn-9031 | Automatic reconstruction initiated for Disk Array | MAP 3110 for a PCI-X or PCIe controller or MAP 3210 for a PCIe2 or a PCIe3 controller |
| nnnn-9032 | Disk array is degraded due to a missing or failed disk | MAP 3110 for a PCI-X or PCIe controller or MAP 3210 for a PCIe2 or a PCIe3 controller |
| nnnn-9041 | Background disk array parity checking detected and corrected errors | MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller |
| nnnn-9042 | Background disk array parity checking detected and corrected errors on specified disk | MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller |
| nnnn-9050 | Required cache data can not be located for one or more disks | MAP 3131 for a PCI-X or PCIe controller or MAP 3231 for a PCIe2 or a PCIe3 controller |
| nnnn-9051 | Cache data exists for one or more missing or failed disks | MAP 3132 for a PCI-X or PCIe controller or MAP 3232 for a PCIe2 or a PCIe3 controller |
| nnnn-9052 | Cache data exists for one or more modified disks | MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller |
| nnnn-9054 | RAID controller resources not available due to previous problems | MAP 3121 for a PCI-X or PCIe controller or MAP 3221 for a PCIe2 or a PCIe3 controller |
| nnnn-9060 | One or more disk pairs are missing from a RAID 10 disk array | MAP 3111 for a PCI-X or PCIe controller or MAP 3211 for a PCIe2 or a PCIe3 controller |
nnnn-9061 |
One or more disks are missing from a RAID 0 disk array | MAP 3111 for a PCI-X or PCIe controller or MAP 3211 for a PCIe2 or a PCIe3 controller |
| nnnn-9063 | Maximum number of functional disk arrays has been exceeded | MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller |
| nnnn-9073 | Multiple controllers connected in an invalid configuration | |
| nnnn-9074 | Multiple controllers not capable of similar functions or controlling same set of devices | |
| nnnn-9075 | Incomplete multipath connection between controller and remote controller | |
| nnnn-9076 | Missing remote controller | |
nnnn-9081 |
Controller detected device error during internal media recovery | MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller |
| nnnn-9090 | Disk has been modified after last known status | MAP 3133 for a PCI-X or PCIe controller or MAP 3233 for a PCIe2 or a PCIe3 controller |
| nnnn-9091 | Incorrect disk configuration change has been detected | MAP 3133 for a PCI-X or PCIe controller or MAP 3233 for a PCIe2 or a PCIe3 controller |
| nnnn-9092 | Disk requires format before use | MAP 3134 for a PCI-X or PCIe controller or MAP 3234 for a PCIe2 or a PCIe3 controller |
| nnnn-FF3D | Temporary controller failure | MAP 210 – replace controller |
| nnnn-FFF3 | Disk media format bad | MAP 3135 for a PCI-X or PCIe controller or MAP 3235 for a PCIe2 or a PCIe3 controller |
nnnn-FFF4 |
Disk error | MAP 210 – replace disk |
| nnnn-FFFC | Device recovered T10 DIF device bus error | MAP 3250 for a PCIe2 or a PCIe3 controller |
| nnnn-FFFD | Controller recovered T10 DIF device bus error | MAP 3250 for a PCIe2 or a PCIe3 controller |
| nnnn-FFFE | Various errors requiring SAS fabric problem isolation |