POWER7 information

Service request numbers

With a service request number (SRN) obtained from error log analysis or from the AIX® error log, use the following table to determine which maintenance analysis procedures (MAPs) to use.

The following table includes only SRNs that are associated with the MAPs contained in this document.

Table 1. SRN to MAP index
SRN Description MAP
nnnn-101 Controller configuration error MAP 210 – replace controller

nnnn-710

nnnn-713

Controller failure MAP 210 – replace controller
nnnn-720 Controller device bus configuration error
SRNs are associated with MAPs based on the value of nnnn.
  • If nnnn is 2D14 or 2D15, use MAP 4150
  • If nnnn is 2D16 - 2D18 or 2D26 - 2D28, use MAP 4050
  • For all other values of nnnn, use MAP 3150 for a PCI-X or PCIe controller or use MAP 3250 for a PCIe2 or a PCIe3 controller
nnnn-102E Out of alternate disk storage for storage MAP 210 – replace disk
nnnn-3002 Addressed device failed to respond to selection MAP 210 – replace device
nnnn-3010 Disk returned wrong response to controller MAP 210 – replace disk

nnnn-3020

nnnn-3100

nnnn-3109

nnnn-310C

nnnn-310D

nnnn-3110

Various errors requiring SAS fabric problem isolation
SRNs are associated with MAPs based on the value of nnnn.
  • If nnnn is 2D14 or 2D15, use MAP 4150
  • If nnnn is 2D16 - 2D18 or 2D26 - 2D28, use MAP 4050
  • For all other values of nnnn, use MAP 3150 for a PCI-X or PCIe controller or use MAP 3250 for a PCIe2 or a PCIe3 controller
nnnn-4010 Configuration error, incorrect connection between cascaded enclosures MAP 3142 for a PCI-X or PCIe controller or MAP 3242 for a PCIe2 or a PCIe3 controller
nnnn-4020 Configuration error, connections exceed controller design limits MAP 3143 for a PCI-X or PCIe controller or MAP 3243 for a PCIe2 or a PCIe3 controller
nnnn-4030 Configuration error, incorrect multipath connection
SRNs are associated with MAPs based on the value of nnnn.
  • If nnnn is 2D14 or 2D15, use MAP 4144
  • If nnnn is 2D16 - 2D18 or 2D26 - 2D28, use MAP 4044
  • For all other values of nnnn, use MAP 3144 for a PCI-X or PCIe controller or MAP 3244 for a PCIe2 or a PCIe3 controller
nnnn-4040 Configuration error, incomplete multipath connection between controller and enclosure detected
SRNs are associated with MAPs based on the value of nnnn.
  • If nnnn is 2D14 or 2D15, use MAP 4144
  • If nnnn is 2D16 - 2D18 or 2D26 - 2D28, use MAP 4044
  • For all other values of nnnn, use MAP 3144 for a PCI-X or PCIe controller or MAP 3244 for a PCIe2 or a PCIe3 controller
nnnn-4041 Configuration error, incomplete multipath connection between enclosures and device detected MAP 3146 for a PCI-X or PCIe controller or MAP 3246 for a PCIe2 or a PCIe3 controller
nnnn-4050 Attached enclosure does not support required multipath function MAP 3148 for a PCI-X or PCIe controller or MAP 3248 for a PCIe2 or a PCIe3 controller
nnnn-4060 Multipath redundancy level got worse
SRNs are associated with MAPs based on the value of nnnn.
  • If nnnn is 2D14 or 2D15, use MAP 4153
  • If nnnn is 2D16 - 2D18 or 2D26 - 2D28, use MAP 4053
  • For all other values of nnnn, use MAP 3153 for a PCI-X or PCIe controller or MAP 3253 for a PCIe2 or a PCIe3 controller
nnnn-4080 Thermal error, controller exceeded maximum operating temperature MAP 3295 for a PCIe2 or a PCIe3 controller
nnnn-4085 Please contact your next level of support or service provider MAP 3290 for a PCIe2 or a PCIe3 controller
nnnn-4100 Device bus fabric error
SRNs are associated with MAPs based on the value of nnnn.
  • If nnnn is 2D14 or 2D15, use MAP 4152
  • If nnnn is 2D16 - 2D18 or 2D26 - 2D28, use MAP 4052
  • For all other values of nnnn, use MAP 3152 for a PCI-X or PCIe controller or MAP 3252 for a PCIe2 or a PCIe3 controller
nnnn-4101 Temporary device bus fabric error
SRNs are associated with MAPs based on the value of nnnn.
  • If nnnn is 2D14 or 2D15, use MAP 4152
  • If nnnn is 2D16 - 2D18 or 2D26 - 2D28, use MAP 4052
  • For all other values of nnnn, use MAP 3152 for a PCI-X or PCIe controller or MAP 3252 for a PCIe2 or a PCIe3 controller
nnnn-4102 Device bus fabric performance degradation MAP 3254 for a PCIe2 or a PCIe3 controller
nnnn-4110 Unsupported enclosure function detected MAP 3145 or a PCI-X or PCIe controller or MAP 3245 for a PCIe2 or a PCIe3 controller
nnnn-4120 Configuration error, cable VPD cannot be read MAP 3261 for a PCIe2 controller
nnnn-4121 Configuration error, required cable is missing MAP 3261 for a PCIe2 or a PCIe3 controller
nnnn-4123 Configuration error, invalid cable Vital Product Data MAP 3261 for a PCIe2 controller

nnnn-4150

nnnn-4160

PCI Bus error detected by controller MAP 210 – replace controller, if the problem is not fixed, replace the planar or backplane
nnnn-4170 Controller T10 DIF host bus error MAP 3260 for a PCIe2 or a PCIe3 controller
nnnn-4171 Controller recovered T10 DIF host bus error MAP 3260 for a PCIe2 or a PCIe3 controller
nnnn-7001 Temporary disk data error MAP 210 – replace disk

nnnn-8008

nnnn-8009

A permanent cache battery pack failure occurred

Impending cache battery pack failure

MAP 3100 for a PCI-X or PCIe controller

nnnn-8150

nnnn-8157

Controller Failure MAP 210 – replace controller

nnnn-9000

nnnn-9001

nnnn-9002

Controller detected device error during configuration discovery MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller
nnnn-9008 Controller does not support function expected for one or more disk MAP 3130 for a PCI-X or PCIe controller or MAP 3230 for a PCIe2 or a PCIe3 controller
nnnn-9010 Cache data associated with attached disks cannot be found MAP 3120 for a PCI-X or PCIe controller or MAP 3220 for a PCIe2 or a PCIe3 controller
nnnn-9011 Cache data belongs to disks other than those attached MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller

nnnn-9020

nnnn-9021

nnnn-9022

Two or more disks are missing from a RAID 5 or RAID 6 Disk Array MAP 3111 for a PCI-X or PCIe controller or MAP 3211 for a PCIe2 or a PCIe3 controller
nnnn-9023 One or more disk array members are not at required physical locations MAP 3112 for a PCI-X or PCIe controller or MAP 3212 for a PCIe2 or a PCIe3 controller
nnnn-9024 Physical location of disk array members conflict with another disk array MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller
nnnn-9025 Incompatible disk installed at degraded disk location in disk array MAP 3110 for a PCI-X or PCIe controller or MAP 3210 for a PCIe2 or a PCIe3 controller
nnnn-9026 Previously degraded disk in disk array not found at required physical location MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller
nnnn-9027 Disk array is or would become degraded and parity data is out of synchronization MAP 3113 for a PCI-X or PCIe controller or MAP 3213 for a PCIe2 or a PCIe3 controller
nnnn-9028 Maximum number of functional disk arrays has been exceeded MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller
nnnn-9029 Maximum number of functional disk array disks has been exceeded MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller
nnnn-9030 Disk array is degraded due to missing/failed disk MAP 3110 for a PCI-X or PCIe controller or MAP 3210 for a PCIe2 or a PCIe3 controller
nnnn-9031 Automatic reconstruction initiated for Disk Array MAP 3110 for a PCI-X or PCIe controller or MAP 3210 for a PCIe2 or a PCIe3 controller
nnnn-9032 Disk array is degraded due to a missing or failed disk MAP 3110 for a PCI-X or PCIe controller or MAP 3210 for a PCIe2 or a PCIe3 controller
nnnn-9041 Background disk array parity checking detected and corrected errors MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller
nnnn-9042 Background disk array parity checking detected and corrected errors on specified disk MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller
nnnn-9050 Required cache data can not be located for one or more disks MAP 3131 for a PCI-X or PCIe controller or MAP 3231 for a PCIe2 or a PCIe3 controller
nnnn-9051 Cache data exists for one or more missing or failed disks MAP 3132 for a PCI-X or PCIe controller or MAP 3232 for a PCIe2 or a PCIe3 controller
nnnn-9052 Cache data exists for one or more modified disks MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller
nnnn-9054 RAID controller resources not available due to previous problems MAP 3121 for a PCI-X or PCIe controller or MAP 3221 for a PCIe2 or a PCIe3 controller
nnnn-9060 One or more disk pairs are missing from a RAID 10 disk array MAP 3111 for a PCI-X or PCIe controller or MAP 3211 for a PCIe2 or a PCIe3 controller

nnnn-9061

nnnn-9062

One or more disks are missing from a RAID 0 disk array MAP 3111 for a PCI-X or PCIe controller or MAP 3211 for a PCIe2 or a PCIe3 controller
nnnn-9063 Maximum number of functional disk arrays has been exceeded MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller
nnnn-9073 Multiple controllers connected in an invalid configuration
SRNs are associated with MAPs based on the value of nnnn.
  • If nnnn is 2D14 or 2D15, use MAP 4140
  • If nnnn is 2D16 - 2D18 or 2D26 - 2D28, use MAP 4040
  • For all other values of nnnn, use MAP 3140 for a PCI-X or PCIe controller or MAP 3240 for a PCIe2 or a PCIe3 controller
nnnn-9074 Multiple controllers not capable of similar functions or controlling same set of devices
SRNs are associated with MAPs based on the value of nnnn.
  • If nnnn is 2D14 or 2D15, use MAP 4141
  • If nnnn is 2D16 - 2D18 or 2D26 - 2D28, use MAP 4041
  • For all other values of nnnn, use MAP 3141 for a PCI-X or PCIe controller or MAP 3241 for a PCIe2 or a PCIe3 controller
nnnn-9075 Incomplete multipath connection between controller and remote controller
SRNs are associated with MAPs based on the value of nnnn.
  • If nnnn is 2D14 or 2D15, use MAP 4149
  • If nnnn is 2D16 - 2D18 or 2D26 - 2D28, use MAP 4049
  • For all other values of nnnn, use MAP 3149 for a PCI-X or PCIe controller or MAP 3249 for a PCIe2 or a PCIe3 controller
nnnn-9076 Missing remote controller
SRNs are associated with MAPs based on the value of nnnn.
  • If nnnn is 2D14 or 2D15, use MAP 4147
  • If nnnn is 2D16 - 2D18 or 2D26 - 2D28, use MAP 4047
  • For all other values of nnnn, use MAP 3147 for a PCI-X or PCIe controller or MAP 3247 for a PCIe2 or a PCIe3 controller

nnnn-9081

nnnn-9082

Controller detected device error during internal media recovery MAP 3190 for a PCI-X or PCIe controller or MAP 3290 for a PCIe2 or a PCIe3 controller
nnnn-9090 Disk has been modified after last known status MAP 3133 for a PCI-X or PCIe controller or MAP 3233 for a PCIe2 or a PCIe3 controller
nnnn-9091 Incorrect disk configuration change has been detected MAP 3133 for a PCI-X or PCIe controller or MAP 3233 for a PCIe2 or a PCIe3 controller
nnnn-9092 Disk requires format before use MAP 3134 for a PCI-X or PCIe controller or MAP 3234 for a PCIe2 or a PCIe3 controller
nnnn-FF3D Temporary controller failure MAP 210 – replace controller
nnnn-FFF3 Disk media format bad MAP 3135 for a PCI-X or PCIe controller or MAP 3235 for a PCIe2 or a PCIe3 controller

nnnn-FFF4

nnnn-FFF6

nnnn-FFFA

Disk error MAP 210 – replace disk
nnnn-FFFC Device recovered T10 DIF device bus error MAP 3250 for a PCIe2 or a PCIe3 controller
nnnn-FFFD Controller recovered T10 DIF device bus error MAP 3250 for a PCIe2 or a PCIe3 controller
nnnn-FFFE Various errors requiring SAS fabric problem isolation
SRNs are associated with MAPs based on the value of nnnn.
  • If nnnn is 2D14 or 2D15, use MAP 4150
  • If nnnn is 2D16 - 2D18 or 2D26 - 2D28, use MAP 4050
  • For all other values of nnnn, use MAP 3150 for a PCI-X or PCIe controller or MAP 3250 for a PCIe2 or a PCIe3 controller


Send feedback | Rate this page

Last updated: Thu, October 10, 2013