Use the following tables to find the symptom you are experiencing. If you cannot find your symptom, contact your next level of support.
| Symptom | What you should do: |
|---|---|
| You have an open service event in the service action event log. | Go to Starting a repair action. |
| You have parts to exchange or a corrective action to perform. |
|
| You need to verify that a part exchange or corrective action corrected the problem. |
|
| You need to verify correct system operation. |
|
| Symptom | What you should do: |
|---|---|
The partitions do not activate - partition configuration is damaged |
Restore the partition configuration data using IVM. See Backing up and restoring partition data |
| Other partition problems when the server is managed by IVM | Perform Troubleshooting with the Integrated Virtualization Manager |
| Symptom | What you should do: |
|---|---|
| The system attention LED on the control panel is on. | Go to Linux fast-path problem isolation. |
| The rack identify LED does not operate properly. | Go to the Linux fast-path problem isolation. |
| The rack indicator LED does not turn on, but a drawer identify LED is on. |
|
| Symptom | What you should do: |
|---|---|
| 01 does not appear in the upper-left corner of the operator panel display after the power is connected and before pressing the power-on button. Other symptoms appear in the operator panel display or LEDs before the power on button is pressed. | Go to Power problems. |
| A bouncing or scrolling ball (moving row of dots) remains on the operator panel display, or the operator panel display is filled with dashes or blocks. | Verify that the operator panel connections to the system backplane are connected and properly seated. Also, reseat the Service Processor card. If a client computer (such as a PC with Ethernet capability and a Web browser) is available, connect it to the service processor in the server that is displaying the symptom. To connect a personal computer with Ethernet capability and a Web browser, or an ASCII terminal, to access the Advanced System Management Interface (ASMI), go to Managing your server using the Advanced System Management Interface.
If you do not have a PC or ASCII terminal, replace the following one at a time (go to Finding parts, locations, and addresses to determine the part number and correct exchange procedure):
|
| You have a blank display on the operator panel. Other LEDs on the operator panel appear to behave normally. | Verify that the operator panel connections to the system backplane are connected and properly seated. If a client computer (such as a PC with Ethernet capability and a Web browser) is available, connect it to the service processor in the server that is displaying the symptom. To connect a personal computer with Ethernet capability and a Web browser, or an ASCII terminal, to access the Advanced System Management Interface (ASMI), go to Managing your server using the Advanced System Management Interface.
If you do not have a PC or ASCII terminal, replace the following one at a time (go to Finding parts, locations, and addresses to determine the part number and correct exchange procedure):
|
| You have a blank display on the operator panel. Other LEDs on the operator panel are off. | Go to Power problems. |
| Symptom | What you should do: |
|---|---|
| You have an 8-digit error code displayed. | Look up the reference code in the Reference codes section
of the information center. Note: If the repair for this code does
not involve replacing a FRU (for
instance, running an AIX® command
that fixes the problem or changing a hot-pluggable FRU), then
update the AIX error
log after the problem is resolved by performing the following steps:
On systems with a fault indicator LED, this changes the "fault indicator" LED from the "fault" state to the "normal" state. |
| The system stops with an 8-digit error code displayed when booting. | Look up the reference code in the Reference codes section of the information center. |
| The system stops and a 4-digit code displays on the control panel that does not begin with 0 or 2. | Look up the reference code in the Reference codes section of the information center. |
| The system stops and a 4-digit code displays on the control panel that begins with 0 or 2 is displayed in the operator panel display. | Record SRN 101-xxxx where xxxx is the 4-digit code displayed in the control panel, then look up this reference code in the Reference codes section of the information center. Follow the instructions given in the Description and Action column for your SRN. |
| The system stops and a 3-digit number displays on the control panel. | Add 101– to the left of the three digits to create an SRN, then look up this reference code in the Reference codes section of the information center. Follow the instructions given in the Description and Action column for your SRN. If there is a location code displayed under the 3-digit error code, look at the location to see if it matches the failing component that the SRN pointed to. If they do not match, perform the action given in the error code table. If the problem still exists, then replace the failing component from the location code. If there is a location code displayed under the 3-digit error code, record the location code. Record SRN 101-xxx, where xxx is the 3-digit number displayed in the operator panel display, then look up this reference code in the Reference codes section of the information center. Follow the instructions given in the Description and Action column for your SRN. |
| Symptom | What you should do: |
|---|---|
| The management console cannot be used to manage a managed system, or the connection to the managed system is failing. | If the managed system is operating normally
(no error codes or other symptoms), the management console might have a problem,
or the connection to the managed system might be damaged or incorrectly
cabled. Do the following:
|
| The management console (HMC only) cannot call out using the attached modem and the customer's telephone line. | If the managed system is operating normally
(no error codes or other symptoms), the management console might have a problem,
or the connection to the modem and telephone line might have a problem.
Do the following:
|
| Symptom | What you should do: |
|---|---|
| All display problems. |
|
| There appears to be a display problem (distortion, blurring, and so on) | Go to the problem determination procedures for the display. |
| Symptom | What you should do: |
|---|---|
| The system will not power on and no error codes are available. | Go to Power problems. |
| The power LEDs on the operator panel and the power supply do not come on or stay on. |
|
| The power LEDs on the operator panel and the power supply come on and stay on, but the system does not power on. |
|
| A rack or a rack-mounted unit will not power on. |
|
| The cooling fan(s) do not come on, or come on but do not stay on. |
|
| The system attention LED on the operator panel is on and there is no error code displayed. |
|
| Symptom | What you should do: |
|---|---|
| The system stopped and a code is displayed on the operator panel. | Go to Starting a repair action. |
| 01 is displayed in the upper-left corner of the operator panel and the fans are off. | The service processor is ready. The system is waiting for power-on. Boot the system. If the boot is unsuccessful, and the system returns to the default display (indicated by 01 in the upper-left corner of the operator panel), go to MAP 0020: Problem determination procedure. |
| The operator panel displays STBY. | The service processor is ready. The server was
shut down by the operating system and is still powered on. This condition
can be requested by a privileged system user with no faults. Go to Starting a repair action.
Note: See the service processor error log for possible operating
system fault indications.
|
| All of the system POST indicators are displayed on the firmware console, the system pauses and then restarts. The term POST indicators refers to the device mnemonics (the words memory, keyboard, network, scsi, and speaker) that appear on the firmware console during the power-on self-test (POST). | Go to Problems with loading and starting the operating system. |
| The system stops and all of the POST indicators are displayed on the firmware console. The term POST indicators refers to the device mnemonics (the words memory, keyboard, network, scsi, and speaker) that appear on the firmware console during the power-on self-test (POST). | Go to Problems with loading and starting the operating system. |
| The system stops and the message starting software please wait...is displayed on the firmware console. | Go to Problems with loading and starting the operating system. |
| The system does not respond to the password being entered or the system login prompt is displayed when booting in service mode. |
If the problem is fixed, go to MAP 0410: Repair checkout. |
| The system stops with a prompt to enter a password. | Enter the password. You cannot continue until a correct password has been entered. When you have entered a valid password, go to the beginning of this table and wait for one of the other conditions to occur. |
| The system does not respond when the password is entered. | Go to Step 1020-2. |
| No codes are displayed on the operator panel within a few seconds of turning on the system. The operator panel is blank before the system is powered on. | Reseat the operator panel cable. If the problem
is not resolved, replace in the following order:
If the problem is fixed, go to MAP 0410: Repair checkout. If the problem is still not corrected, go to MAP 0020: Problem determination procedure. |
| The SMS configuration list or boot sequence selection menu shows more SCSI devices attached to a controller/adapter than are actually attached. | A device may be set to use the same SCSI bus
ID as the control adapter. Note the ID being used by the controller/adapter
(this can be checked and/or changed through an SMS utility), and verify
that no device attached to the controller is set to use that ID. If settings do not appear to be in conflict:
Note: In a "twin-tailed" configuration where there is more than
one initiator device (normally another system) attached to the SCSI
bus, it may be necessary to use SMS utilities to change the ID of
the SCSI controller or adapter.
|
| You suspect a cable problem. | Go to Adapters, Devices and Cables for Multiple Bus Systems. |
| You have a problem that does not prevent the system from booting. The operator panel is functional and the rack indicator LED operates as expected. | Go to MAP 0020: Problem determination procedure. |
| All other symptoms. | Go to MAP 0020: Problem determination procedure. |
| All other problems. | Go to MAP 0020: Problem determination procedure. |
| You do not have a symptom. | Go to MAP 0020: Problem determination procedure. |
| You have parts to exchange or a corrective action to perform. |
|
| You need to verify that a part exchange or corrective action corrected the problem. | Go to MAP 0410: Repair checkout. |
| You need to verify correct system operation. | Go to MAP 0410: Repair checkout. |
| The system stopped. A POST indicator is displayed on the system console and an eight-digit error code is not displayed. | If the POST indicator represents:
|
| The diagnostic operating instructions are displayed. | Go to MAP 0020: Problem determination procedure. |
| The system login prompt is displayed. | If you are loading the diagnostics from a CD-ROM,
you may not have pressed the correct key or you may not have pressed
the key soon enough when you were trying to indicate a service mode
IPL of the diagnostic programs. If this is the case, start again at
the beginning of this step. Note: Perform the system shutdown procedure
before turning off the system.
If you are sure you pressed the correct key in a timely manner, go to Step 1020-2. If you are loading diagnostics from a Network Installation Management (NIM) server, check for the following:
Verify the settings and the status of the network. If you continue to have problems refer to Problems with loading and starting the operating system and follow the steps for network boot problems. |
| The System Management Services (SMS) menu is displayed when you were trying to boot standalone diagnostics. | If you are loading diagnostics from the CD-ROM,
you may not have pressed the correct key when you were trying to indicate
a service mode IPL of the diagnostic programs. If this is the case,
try to boot the CD-ROM again and press the correct key. If you are sure you pressed the correct key, the device or media you are attempting to boot from may be faulty.
|
| The SMS boot sequence selection menu or remote IPL menu does not show all of the bootable devices in the partition or system. | If an AIX or Linux partition is being booted, verify that the devices that you expect to see in the list are assigned to this partition. If they are not, use the management console to reassign the required resources. If they are assigned to this partition, go to Problems with loading and starting the operating system to resolve the problem. |