Use the following procedure and record the data as shown.
- Press the Increment (↑) button until the function
you want appears in the Function display (example: 63).
- Press Enter on the control panel; ** appears next to the
function number to indicate that you are in the sub-function mode. This is the entry point and exit point for sub-function
mode).
If the data is xx _ _ _ _ FF (where xx =
the function number), this function is not available.
- Press the Increment (↑) button until 00 is next to the
function number.
- Press Enter on the control panel. Data appears
in the display. Record the data.
- Press the Increment (↑) button to continue to
the next sub-function (example: 5401).
- Press Enter on the control panel. Record
the data.
- Repeat steps 5 and 6, increasing the sub-function number
one at a time and recording the data until all the suitable data is
collected.
- Press the Increment (↑) or Decrement (↓) buttons to move
from the last sub-function back to ** (example: 633F to 63**).
- Press Enter on the control panel. Doing
this takes you out of sub-function mode, and ** no longer appears.
Repeat steps 1 through 9 for additional data that you were
instructed to collect.
Call your next level of support and give
them the information you collected to write a Licensed Internal Code APAR.