Control panel function codes on the 7037-A50 and 7047-185 models

Learn about the control panel function codes used to indicate status and function options for the 7037-A50 server and the 7047-185 workstation.

The following table includes descriptions of the control panel function codes.
Table 1. Control panel (32-character) function codes
Function code Function selected
01 Displays the current IPL parameters. This function is available in both normal and manual operating mode.
02 Used to select the firmware IPL mode.
03 Not applicable.
04 Lamp test; all displays and indicators are lit. This function is available in both normal and manual operating mode.
05 Used for Remind mode. This function is available in both normal and manual operating mode.
06 Displays the base motherboard controller (BMC) version. This function is available in both normal and manual operating mode.
07 through 08 Not applicable.
09 Displays the base motherboard controller (BMC) fan speed. This function is available in both normal and manual operating mode.
10 Displays the temperature. This function is available in both normal and manual operating mode.
11 through 19 Not applicable.
20 Displays the machine type and model. This function is available in both normal and manual operating mode.
21 Not supported.
22 Forces a partition dump. To perform a system main storage dump, see Performing dumps.
23 through 49 Not applicable.

If you cannot find the function code in this chart, added features or devices might not have been available when this information was produced. Look on the control panel for supplemental unit function code information for the function code that you displayed.


Send feedback | Rate this page