Hardware specifications provide detailed information for your expansion unit, including dimensions, electrical, power, temperature, environment, and service clearances.
Pictured is the 5094 expansion unit or 9094 expansion unit with 5088 PCI-X expansion unit. |
![]() |
||
| Dimensions | Width | Depth | Height |
| Metric | 485 mm | 1075 mm | 1110 mm |
| English | 19.1 in. | 42.3 in. | 43.8 in. |
| Maximum configuration weight | 418 kg (922 lb.) | ||
| Electrical | |||
| kVA (maximum) | 1.470 | ||
| Rated voltage and frequency | 200-240 V ac at 50-60 plus or minus 0.5 Hz | ||
| Thermal output (maximum) | 4573 Btu/hr | ||
| Power requirements (maximum) | 1340 W | ||
| Power factor | 0.91 | ||
| Inrush current | 90 A | ||
| Leakage current (maximum) | 3.5 mA | ||
| Phase | 1 | ||
| Plug type (Canada and U.S.) | 5, 10, or 34 | ||
| Power cord length | 1.8 m (6 ft. ) (U.S. only) or 4.3 m (14 ft. ) | ||
| Temperature requirements | |||
| Operating | 10 degrees to 38 degrees C (50 degrees to 100.4 degrees F) | ||
| Nonoperating | 1 degrees to 60 degrees C (33.8 degrees to 140 degrees F) | ||
| Environmental requirements | Operating | Nonoperating | |
| Noncondensing humidity | 8 to 80% | 8 to 80% | |
| Wet bulb temperature | 23 degrees C (73.4 degrees F) | 27 degrees C (80.6 degrees F) | |
| Maximum altitude | 3048 m (10000 ft.) | ||
| Noise emissions1 | Operating | Idle | |
| LWAd | 6.7 bels | 6.6 bels | |
| LpAm (1-meter bystander) | 48 dB | 48 dB | |
| Service clearances | |||
| Front | Back | Sides2 | Top2 |
| 762 mm | 762 mm | 762 mm | 762 mm |
| 30 in. | 30 in. | 30 in. | 30 in. |
Note:
|
|||