Service request numbers

With a service request number (SRN) obtained from error log analysis or from the AIX® error log, use the following table to determine which maintenance analysis procedures (MAPs) to use.

The following table includes only SRNs that are associated with the MAPs contained in this document.

Table 1. SRN to MAP index
SRN Description MAP
nnnn-101 Controller configuration error MAP 210 – replace controller
nnnn-710
nnnn-713
Controller failure MAP 210 – replace controller
nnnn-720 Controller device bus configuration error

SRNs are associated with MAPs based on the value of nnnn. For all other values of nnnn, use MAP 3150 for a PCIe controller or use MAP 3250 for a PCIe3 controller

nnnn-102E Out of alternate disk storage for storage MAP 210 – replace disk
nnnn-3002 Addressed device failed to respond to selection MAP 210 – replace device
nnnn-3010 Disk returned wrong response to controller MAP 210 – replace disk
nnnn-3020
nnnn-3100
nnnn-3109
nnnn-310C
nnnn-310D
nnnn-3110
Various errors requiring SAS fabric problem isolation

SRNs are associated with MAPs based on the value of nnnn. For all other values of nnnn, use MAP 3150 for a PCIe controller or use MAP 3250 for a PCIe3 controller

nnnn-4010 Configuration error, incorrect connection between cascaded enclosures MAP 3142 for a PCIe controller or MAP 3242 for a PCIe3 controller
nnnn-4020 Configuration error, connections exceed controller design limits MAP 3143 for a PCIe controller or MAP 3243 for a PCIe3 controller.
nnnn-4030 Configuration error, incorrect multipath connection

SRNs are associated with MAPs based on the value of nnnn. For all other values of nnnn, use MAP 3244 for a PCIe3 controller

nnnn-4040 Configuration error, incomplete multipath connection between controller and enclosure detected

SRNs are associated with MAPs based on the value of nnnn. For all other values of nnnn, use MAP 3244 for a PCIe3 controller

nnnn-4041 Configuration error, incomplete multipath connection between enclosures and device detected MAP 3146 for a PCIe controller or MAP 3246 for a PCIe3 controller
nnnn-4050 Attached enclosure does not support required multipath function MAP 3148 for a PCIe controller or MAP 3248 for a PCIe3 controller
nnnn-4060 Multipath redundancy level got worse

SRNs are associated with MAPs based on the value of nnnn. For all other values of nnnn, use MAP 3153 for a PCIe controller or MAP 3253 for a PCIe3 controller.

nnnn-4080 Thermal error, controller exceeded maximum operating temperature MAP 3295 for a PCIe3 controller
nnnn-4085 Please contact your next level of support or service provider MAP 3290 for a PCIe3 controller
nnnn-4086 SAS adapter hardware configuration error MAP 3296 for a PCIe3 controller
nnnn-4100 Device bus fabric error

SRNs are associated with MAPs based on the value of nnnn. For all other values of nnnn, use MAP 3152 for a PCIe controller or MAP 3252 for a PCIe3 controller.

nnnn-4101 Temporary device bus fabric error

SRNs are associated with MAPs based on the value of nnnn. For all other values of nnnn, use MAP 3152 for a PCIe controller or MAP 3252 for a PCIe3 controller.

nnnn-4102 Device bus fabric performance degradation MAP 3254 for a PCIe3 controller
nnnn-4110 Unsupported enclosure function detected MAP 3145 for a PCIe controller or MAP 3245 for a PCIe3 controller
nnnn-4120 Configuration error, cable VPD cannot be read MAP 3261 for a PCIe3 controller
nnnn-4121 Configuration error, required cable is missing MAP 3261 for a PCIe3 controller
nnnn-4123 Configuration error, invalid cable Vital Product Data MAP 3261 for a PCIe3 controller
nnnn-4150
nnnn-4160
PCI Bus error detected by controller MAP 210 – replace controller, if the problem is not fixed, replace the planar or backplane
nnnn-4170 Controller T10 DIF host bus error MAP 3260 for a PCIe3 controller
nnnn-4171 Controller recovered T10 DIF host bus error MAP 3260 for a PCIe3 controller
nnnn-7001 Temporary disk data error MAP 210 – replace disk
nnnn-8150
nnnn-8157
Controller Failure MAP 210 – replace controller
nnnn-9000
nnnn-9001
nnnn-9002
Controller detected device error during configuration discovery MAP 3290 for a PCIe3 controller
nnnn-9008 Controller does not support function expected for one or more disk MAP 3230 for a PCIe3 controller
nnnn-9010 Cache data associated with attached disks cannot be found MAP 3220 for a PCIe3 controller
nnnn-9011 Cache data belongs to disks other than those attached MAP 3290 for a PCIe3 controller
nnnn-9020
nnnn-9021
nnnn-9022
Two or more disks are missing from a RAID 5 or RAID 6 Disk Array MAP 3211 for a PCIe3 controller
nnnn-9023 One or more disk array members are not at required physical locations MAP 3212 for a PCIe3 controller
nnnn-9024 Physical location of disk array members conflict with another disk array MAP 3290 for a PCIe3 controller
nnnn-9025 Incompatible disk installed at degraded disk location in disk array MAP 3210 for a PCIe3 controller
nnnn-9026 Previously degraded disk in disk array not found at required physical location MAP 3290 for a PCIe3 controller
nnnn-9027 Disk array is or would become degraded and parity data is out of synchronization MAP 3213 for a PCIe3 controller
nnnn-9028 Maximum number of functional disk arrays has been exceeded MAP 3290 for a PCIe3 controller
nnnn-9029 Maximum number of functional disk array disks has been exceeded MAP 3290 for a PCIe3 controller
nnnn-9030 Disk array is degraded due to missing/failed disk MAP 3210 for a PCIe3 controller
nnnn-9031 Automatic reconstruction initiated for Disk Array MAP 3210 for a PCIe3 controller
nnnn-9032 Disk array is degraded due to a missing or failed disk MAP 3210 for a PCIe3 controller
nnnn-9041 Background disk array parity checking detected and corrected errors MAP 3290 for a PCIe3 controller
nnnn-9042 Background disk array parity checking detected and corrected errors on specified disk MAP 3290 for a PCIe3 controller
nnnn-9050 Required cache data can not be located for one or more disks MAP 3231 for a PCIe3 controller
nnnn-9051 Cache data exists for one or more missing or failed disks MAP 3232 for a PCIe3 controller
nnnn-9052 Cache data exists for one or more modified disks MAP 3290 for a PCIe3 controller
nnnn-9054 RAID controller resources not available due to previous problems MAP 3221 for a PCIe3 controller
nnnn-9060 One or more disk pairs are missing from a RAID 10 disk array or missing a tier from a tiered disk array MAP 3211 for a PCIe3 controller
nnnn-9061
nnnn-9062
One or more disks are missing from a RAID 0 disk array MAP 3211 for a PCIe2 or a PCIe3 controller
nnnn-9063 Maximum number of functional disk arrays has been exceeded MAP 3290 for a PCIe3 controller
nnnn-9073 Multiple controllers connected in an invalid configuration

SRNs are associated with MAPs based on the value of nnnn. For all other values of nnnn, use MAP 3240 for a PCIe3 controller

nnnn-9074 Multiple controllers not capable of similar functions or controlling same set of devices

SRNs are associated with MAPs based on the value of nnnn. For all other values of nnnn, use MAP 3241 for a PCIe3 controller

nnnn-9075 Incomplete multipath connection between controller and remote controller

SRNs are associated with MAPs based on the value of nnnn. For all other values of nnnn, use MAP 3249 for a PCIe3 controller

nnnn-9076 Missing remote controller

SRNs are associated with MAPs based on the value of nnnn. For all other values of nnnn, use MAP 3247 for a PCIe3 controller

nnnn-9081
nnnn-9082
Controller detected device error during internal media recovery MAP 3290 for a PCIe3 controller
nnnn-9090 Disk has been modified after last known status MAP 3233 for a PCIe3 controller
nnnn-9091 Incorrect disk configuration change has been detected MAP 3233 for a PCIe3 controller
nnnn-9092 Disk requires format before use MAP 3234 for a PCIe3 controller
nnnn-FF3D Temporary controller failure MAP 210 – replace controller
nnnn-FFF3 Disk media format bad MAP 3235 for a PCIe3 controller
nnnn-FFF4
nnnn-FFF6
nnnn-FFFA
Disk error MAP 210 – replace disk
nnnn-FFFC Device recovered T10 DIF device bus error MAP 3250 for a PCIe3 controller
nnnn-FFFD Controller recovered T10 DIF device bus error MAP 3250 for a PCIe3 controller
nnnn-FFFE Various errors requiring SAS fabric problem isolation

SRNs are associated with MAPs based on the value of nnnn. For all other values of nnnn, use MAP 3250 for a PCIe3 controller