POWER7 information

Examples: Obtaining additional information from hexadecimal reports

You can get additional information for IOP 90xx reference code product activity log entries at DST by using a type D IPL.

Notes:
  • The term I/O processor indicates an IOP or an IOA.
  • Formatting is available (F4=Additional Information) for IPL from disk (type A or B IPL). Formatting is not available in DST from a type D IPL.

Use the following information and the display examples to interpret the hexadecimal dump information that begins at offset hex 000180.

If the rightmost hexadecimal digit of the offset 000182 is 8, get the format from offset 00019F, and then use the following table to determine which figure to refer to.

Table 1. Format number to figure reference
Format number Refer to the following figures
01

Figure 1

Figure 2

Figure 3

02

Figure 4

Figure 5

Figure 6

03

Figure 7

Figure 8

Figure 9

04

Figure 10

Figure 11

Figure 12

If the rightmost hexadecimal digit of offset 000182 is 2, get the format number from offset 0001B5, and then use the following table to determine which table to refer to.

Table 2. Mapping of format number to table reference
Format number Reference the following tables
01 Table 3
02 Table 4
03 Table 5
04 Table 6
11 Table 7
12 Table 8
13 Table 9
14 Table 10
17 Table 11
20 Table 12

Example: Device formatting log (unformatted information)

Figure 1. Example of hexadecimal report, device formatting log (unformatted information)
                   Display Hexadecimal Report for Resource
 
                                        Serial                  Resource
Name              Type      Model       Number                  Name
STORAGE           6607      070         00-68753
 
Offset          0 1 2 3  4 5 6 7  8 9 A B  C D E F    EBCDIC
000180          F8407800 65320001 90920210 010400FF   8 .......k......
000190          66070000 00001306 87531400 123D0001   ........g.......
0001A0          00000000 00000000 CA000003 00000000   ................
0001B0          65320001 07050011 00000000 00000000   ................
0001C0          00000004 00000003 00000000 00000000   ................
0001D0          F6F6F0F7 13068753 010400FF 00000000   6607..g.........
0001E0          00000000 65320001 07050011 47000001   ................
0001F0          07069205 C0004000 00000021 00000030   ..k.{. .........
000200          00000000 00000000 F6F6F0F7 00071575   ........6607....
000210          010300FF 00000000 00000000 65320001   ................
000220          07050011 47000001 07069205 C0004000   ..........k.{. .
000230          00000000 00000000 00000000 00000000   ................
000240          F6F6F0F7 00259DE8 010200FF 00000000   6607...Y........
000250          00000000 65320001 07050011 47000001   ................
000260          07069205 C0404040 00000000 00000000   ..k.{   ........
000270          00000000 00000000 E2E5C3C4 D6C3E2C3   ........SVCDOCSC
000280          D7D7F2F9 C1F800D5 00000000 00000000   PP29A8.N........
000290          00000000 00000000 00000000 00000000   ................
0002A0          00000000 00000000 00000000 00000000   ................
0002B0          00000000 00000000 00000000 00000000   ................
0002C0          00000000 00000000 00000000 00000000   ................
0002D0          00000000 00000000 C3D7D7F8 F9F2F9D5   ........CPP8929N
0002E0          F6F5F3F2 F9F0F9F2 F0F0F0F0 F0F0F0F0   6532909200000000
0002F0          F0F0F0F0 F0F1F6C3 F0F1F3F3 0000D5D5   0000016C0133..NN
000300          00000000 00000000 00000000 00000000   ................
 
 

Example: Device formatting log template

Figure 2. Example of hexadecimal report, device formatting log template
                   Display Hexadecimal Report for Resource
 
                                        Serial                  Resource
Name              Type      Model       Number                  Name
STORAGE           6607      070         00-68753
 
Offset          0 1 2 3  4 5 6 7  8 9 A B  C D E F
000180          -------- -------- -------- --------
000190          -------- -------- -------- ------01
0001A0          -------- -------- -------- --------
0001B0          -------- -------- -------- --------
0001C0          # errors # errors -------- --------
                detected logged   -------- --------
0001D0          Device1  Device1  Device1  New Dev1
                Type     Serial   UnitAddr Type
0001E0          New Dev1 IOP type IOP      Cache
                Serial   & model  Serial   Type/Mod
0001F0          Cache    -------- -------- --------
                Serial   -------- -------- --------
000200          -------- -------- Device2  Device2
                -------- -------- Type     Serial
000210          Device2  New Dev2 New Dev2 IOP type
                UnitAddr Type     Serial   & model
000220          IOP      Cache    Cache    --------
                Serial   Type/Mod Serial   --------
000230          -------- -------- -------- --------
                -------- -------- -------- --------
000240          Device3  Device3  Device3  New Dev3
                Type     Serial   UnitAddr Type
000250          New Dev3 IOP type IOP      Cache
                Serial   & model  Serial   Type/Mod
000260          Cache    -------- -------- --------
                Serial   -------- -------- --------
 
 

Example: Device formatting log (as formatted information for A or B IPL)

Figure 3. Example of hexadecimal report, device formatting (as formatted information for type A or B IPL)
                 Display Additional Information for Resource
 
                                        Serial                  Resource
Name              Type      Model       Number                  Name
STORAGE           6607      070         00-68753
 
  Device Errors detected . . . . . . . :          4
  Device Errors logged . . . . . . . . :          3
 
  Device  . . . . . . . . . :         1         2         3
       Unit Address . . . . :  010400FF  010300FF  010200FF
       Type . . . . . . . . :      6607      6607      6607
       Serial Number  . . . :  13068753  00071575  00259DE8
    New Device Information:
       Type . . . . . . . . :      ****      ****      ****
       Serial Number  . . . :  00000000  00000000  00000000
    I/O Processor Information:
       Type . . . . . . . . :      6532      6532      6532
       Serial Number  . . . :  07050011  07050011  07050011
    Cache Adaptor Card Information:
       Type . . . . . . . . :      4700      4700      4700
       Serial Number  . . . :  07069205  07069205  07069205
 
 

Example: Array member formatting log (unformatted information)

Figure 4. Example of hexadecimal report, array member formatting log (unformatted information)
                   Display Hexadecimal Report for Resource
 
                                        Serial                  Resource
Name              Type      Model       Number                  Name
STORAGE           6532      001         00-50011
 
Offset          0 1 2 3  4 5 6 7  8 9 A B  C D E F    EBCDIC
000180          F4407800 65320001 90210210 0FFFFFFF   4 ..............
000190          00000000 00000000 00001400 12400002   ............. ..
0001A0          00000000 00000000 CA000003 00000000   ................
0001B0          65320001 07050011 00000000 00000000   ................
0001C0          F6F6F0F7 0025ED09 000200FF 000200FF   6607............
0001D0          F6F6F0F7 00158135 000100FF 000100FF   6607..a.........
0001E0          F6F6F0F7 00259DE8 010200FF 00000000   6607...Y........
0001F0          F6F6F0F7 00008326 010100FF 00000000   6607..c.........
000200          F6F6F0F7 00071575 010300FF 00000000   6607............
000210          F6F6F0F7 13068753 010400FF 00000000   6607..g.........
000220          00000000 00000000 00000000 00000000   ................
000230          00000000 00000000 00000000 00000000   ................
000240          00000000 00000000 00000000 00000000   ................
000250          00000000 00000000 00000000 00000000   ................
000260          000000FF 00000004 00000000 00000000   ................
000270          00000000 E2E5C3C4 D6C3E2C3 D7D7F2F9   ....SVCDOCSCPP29
000280          C1F800D5 00000000 00000000 00000000   A8.N............
000290          00000000 00000000 00000000 00000000   ................
0002A0          00000000 00000000 00000000 00000000   ................
0002B0          00000000 00000000 00000000 00000000   ................
0002C0          00000000 00000000 00000000 00000000   ................
0002D0          00000000 C3D7D7C5 C1F0F2D5 F6F5F3F2   ....CPPEA02N6532
0002E0          F9F0F2F1 F0F0F0F0 F0F0F0F0 F0F0F0F0   9021000000000000
0002F0          F0F0C4F4 F0F1F3F3 0000D5D5 00000000   00D40133..NN....
000300          00000000 00000000 00000000 00000000   ................
 

Example: Array member formatting log template

Figure 5. Example of hexadecimal report, array member formatting log template
                   Display Hexadecimal Report for Resource
 
                                        Serial                  Resource
Name              Type      Model       Number                  Name
STORAGE           6532      001         00-50011
 
Offset          0 1 2 3  4 5 6 7  8 9 A B  C D E F
000180          -------- -------- -------- --------
000190          -------- -------- -------- ------02
0001A0          -------- -------- -------- --------
0001B0          -------- -------- -------- --------
0001C0          Member0  Member0  Expected Current
                Type     Serial   Address  Address
0001D0          Member1  Member1  Expected Current
                Type     Serial   Address  Address
0001E0          Member2  Member2  Expected Current
                Type     Serial   Address  Address
0001F0          Member3  Member3  Expected Current
                Type     Serial   Address  Address
000200          Member4  Member4  Expected Current
                Type     Serial   Address  Address
000210          Member5  Member5  Expected Current
                Type     Serial   Address  Address
000220          Member6  Member6  Expected Current
                Type     Serial   Address  Address
000230          Member7  Member7  Expected Current
                Type     Serial   Address  Address
000240          Member8  Member8  Expected Current
                Type     Serial   Address  Address
000250          Member9  Member9  Expected Current
                Type     Serial   Address  Address
 
 

Example: Array member formatting log (as formatted information for type A or B IPL)

Figure 6. Example of hexadecimal report, array member formatting (as formatted information for type A or B IPL)
                 Display Additional Information for Resource
 
                                        Serial                  Resource
Name              Type      Model       Number                  Name
STORAGE           6532      001         00-50011
 
  Array Member  . . . . . . :        0        1        2        3        4
       Type . . . . . . . . :     6607     6607     6607     6607     6607
       Serial Number  . . . : 0025ED09 00158135 00259DE8 00008326 00071575
    Unit Address:
       Current  . . . . . . : 000200FF 000100FF 00000000 00000000 00000000
       Expected . . . . . . : 000200FF 000100FF 010200FF 010100FF 010300FF
 
  Array Member  . . . . . . :        5        6        7        8        9
       Type . . . . . . . . :     6607     ****     ****     ****     ****
       Serial Number  . . . : 13068753 00000000 00000000 00000000 00000000
    Unit Address:
       Current  . . . . . . : 00000000 00000000 00000000 00000000 00000000
       Expected . . . . . . : 010400FF 00000000 00000000 00000000 00000000
 
 

Example: Configuration formatting log (unformatted information)

Figure 7. Example of hexadecimal report, configuration formatting log (unformatted information)
                   Display Hexadecimal Report for Resource
 
                                        Serial                  Resource
Name              Type      Model       Number                  Name
STORAGE           6532      001         00-50011
 
Offset          0 1 2 3  4 5 6 7  8 9 A B  C D E F    EBCDIC
000180          50407800 65320001 90120210 0FFFFFFF   & ..............
000190          00000000 00000000 00001400 123C0003   ................
0001A0          00000000 00000000 CA000003 00000000   ................
0001B0          65320001 07050011 00000000 00000000   ................
0001C0          00000000 00000000 47000001 07069205   ..............k.
0001D0          F8F6C7F8 F1F4F9C3 D7D7F8F9 F8F100D5   86G8149CPP8981.N
0001E0          00000000 00000000 00000000 00000000   ................
0001F0          00000000 00000000 00000000 00000000   ................
000200          00000000 00000000 00000000 00000000   ................
000210          00000000 00000000 00000000 00000000   ................
000220          00000000 00000000 00000000 00000000   ................
000230          C3D7D7C5 C1F0F2D5 F6F5F3F2 F9F0F1F2   CPPEA02N65329012
000240          F0F0F0F0 F0F0F0F0 F0F0F0F0 F0F0C4F4   00000000000000D4
000250          F0F1F3F4 0000E8D5 00000000 00000000   0134..YN........
 
 

Example: Configuration formatting log template

Figure 8. Example of hexadecimal report, configuration formatting log template
                   Display Hexadecimal Report for Resource
 
                                        Serial                  Resource
Name              Type      Model       Number                  Name
STORAGE           6532      001         00-50011
 
Offset          0 1 2 3  4 5 6 7  8 9 A B  C D E F
000180          -------- -------- -------- --------
000190          -------- -------- -------- ------03
0001A0          -------- -------- -------- --------
0001B0          Current  Current  Current  Current
                IOP type IOP      Cache    Cache
                & model  serial   type     serial
0001C0          Expected Expected Expected Expected
                IOP type IOP      Cache    Cache
                & model  serial   type     serial
            

Configuration formatting log (as formatted information for type A or B IPL)

Figure 9. Example of hexadecimal report, configuration formatting log (as formatted information for type A or B IPL)
                 Display Additional Information for Resource
 
                                        Serial                  Resource
Name              Type      Model       Number                  Name
STORAGE           6532      001         00-50011
 
  Configuration . . . . . . :     Current                Expected
    I/O Processor Information:
       Type . . . . . . . . :         6532                   0000
       Serial Number  . . . :     07050011               00000000
    Cache Adaptor Card Information:
       Type . . . . . . . . :         0000                   4700
       Serial Number  . . . :     00000000               07069205
         

Example: Array addendum formatting log (unformatted information)

Figure 10. Example of hexadecimal report, array addendum formatting log (unformatted information)
                 Display Hexadecimal Report for Resource
 
                                        Serial                  Resource
Name              Type      Model       Number                  Name
STORAGE           2757      001         10-0322005              DC03
 
Offset          0 1 2 3  4 5 6 7  8 9 A B  C D E F    EBCDIC
000000          C5D3F0F5 000000A0 00E00180 82745D0F   EL05........b.).
000010          1FD78000 00002CE0 20100084 049F0000   .P.........d....
000020          902F0000 11000000 00000000 00C70000   .............G..
000030          F2F7F5F7 F0F0F140 F1F060F0 F3F2F2F0   2757001 10-03220
000040          F0F50000 0000F2F7 F5F70002 00020000   05....2757......
000050          00200000 0002FFFF FFFFFFFF 0004FFFF   ................
000060          00000000 00000000 00000000 40404040   ............
000070          40404040 40400000 00000000 00000000         ..........
000080          00000000 00000000 00000000 00000000   ................
000090          00000000 00000000 00000000 00000000   ................
0000A0          00000000 00000000 00000000 00000000   ................
0000B0          00000000 00000000 40404040 40404040   ........
0000C0          40404040 40404040 40404040 40404040
0000D0          40404040 40404040 40404040 40404040
0000E0          F2F7F5F7 F0F0F0F1 0000E2D3 C9C3C9D6   27570001..SLICIO
0000F0          4040E5F5 D9F2D4F0 40400000 00000000     V5R2M0  ......
000100          00B90000 00000000 000000C7 00000000   ...........G....
000110          00000000 00000000 00000000 00000000   ................
000120          00000000 00000000 00000000 00000000   ................
000130          00000000 00000000 00000000 00000000   ................
000140          C4C3F0F3 40404040 40404040 40404040   DC03
000150          D5C5C5C4 E5C1D3C9 C4D740D5 00070001   NEEDVALIDP N....
000160          00000000 A0200007 00000000 00000000   ................
000170          00000000 00000000 0003001E 000000A0   ................
000180          A0407800 27570001 902F0200 4FFFFFFF   . ...*......|...
000190          00000000 00000000 00001400 623E0004   ................
0001A0          F6F6F0F7 0026121D 410500FF 410500FF   6607............
0001B0          F6F6F0F7 00248B85 410400FF 410400FF   6607...e........
0001C0          F6F6F0F7 0014BE1F 410300FF 410300FF   6607............
0001D0          F6F6F0F7 0014C0F0 410200FF 410200FF   6607..{0........
0001E0          F6F6F0F7 001403C8 410100FF 410100FF   6607...H........
0001F0          F6F6F0F7 0014BEA4 410800FF 410800FF   6607...u........
000200          00000000 00000000 00000000 00000000   ................
000210          00000000 00000000 00000000 00000000   ................

Example: Array addendum log template

Figure 11. Example of hexadecimal report, array addendum formatting log template
                 Display Hexadecimal Report for Resource
 
                                        Serial                  Resource
Name              Type      Model       Number                  Name
STORAGE           6532      001         00-50011
 
Offset          0 1 2 3  4 5 6 7  8 9 A B  C D E F

000180          -------- -------- -------- --------
000190          -------- -------- -------- ------04
0001A0          Member10 Member10 Expected Current
                Type     Serial   Address  Address
0001B0          Member11 Member11 Expected Current
                Type     Serial   Address  Address
0001C0          Member12 member12 Expected Current
                Type     Serial   Address  Address
0001D0          Member13 Member13 Expected Current
                Type     Serial   Address  Address
0001E0          Member14 Member14 Expected Current
                Type     Serial   Address  Address
0001F0          Member15 Member15 Expected Current
                Type     Serial   Address  Address
000200          Member16 Member16 Expected Current
                Type     Serial   Address  Address
000210          Member17 Member17 Expected Current
                Type     Serial   Address  Address

Example: Array addendum log (as formatted information for type A or B IPL)

Figure 12. Example of hexadecimal report, array addendum formatting (as formatted information for type A or B IPL)
                 Display Additional Information for Resource
 
                                        Serial                  Resource
Name              Type      Model       Number                  Name
STORAGE           2757      001         10-0322005              DC03
 
  Array Member  . . . . . . :       10       11       12       13       14
       Type . . . . . . . . :     6607     6607     6607     6607     6607
       Serial Number  . . . : 0026121D 00248B85 0014BE1F 0014C0F0 001403C8
    Unit Address:
       Current  . . . . . . : 410500FF 410400FF 410300FF 410200FF 410100FF
       Expected . . . . . . : 410500FF 410400FF 410300FF 410200FF 410100FF
 
  Array Member  . . . . . . :       15       16       17
       Type . . . . . . . . :     6607     ****     ****
       Serial Number  . . . : 0014BEA4 00000000 00000000
    Unit Address:
       Current  . . . . . . : 410800FF 00000000 00000000
       Expected . . . . . . : 410800FF 00000000 00000000
Table 3. Format 01
Description Hex offset
Device errors detected 0001D6 - 0001D9
Device errors logged 0001DA - 0001DD
Device 1 type 0001E6 - 0001E9
Device 1 serial number 0001EA - 0001ED
Device 1 unit address 0001EE - 0001F1
New device 1 type 0001F2 - 0001F5
New device 1 serial number 0001F6 - 0001F9
Device 1 IOA type and model 0001FA - 0001FD
Device 1 IOA serial number 0001FE - 000201
Device 1 Cache type and model 000202 - 000205
Device 1 Cache serial number 000206 - 000209
Device 2 type 00021E - 000221
Device 2 serial number 000222 - 000225
Device 2 unit address 000226 - 000229
New device 2 type 00022A - 00022D
New device 2 serial number 00022E - 000231
Device 2 IOA type and model 000232 - 000235
Device 2 IOA serial number 000236 - 000239
Device 2 cache type and model 00023A - 00023D
Device 2 cache serial number 00023E - 000241
Device 3 type 000256 - 000259
Device 3 serial number 00025A - 00025D
Device 3 unit address 00025E - 000261
New device 3 type 000262 - 000265
New device 3 serial number 000266 - 000269
Device 3 IOA type and model 00026A - 00026D
Device 2 IOA serial number 00026E - 000271
Device 3 cache type and model 000272 - 000275
Device 3 cache serial number 000276 - 000279
Table 4. Format 02
Description Hex offset
Array member 0 type 0001D6 - 0001D9
Array member 0 serial number 0001DA - 0001DD
Array member 0 expected unit address 0001DE - 0001E1
Array member 0 current unit address 0001E2 - 0001E5
Array member 1 type 0001E6 - 0001E9
Array member 1 serial number 0001EA - 0001ED
Array member 1 expected unit address 0001EE - 0001F1
Array member 1 current unit address 0001F2 - 0001F5
Array member 2 type 0001F6 - 0001F9
Array member 2 serial number 0001FA - 0001FD
Array member 2 expected unit address 0001FE - 000201
Array member 2 current unit address 000202 - 000205
Array member 3 type 000206 - 000209
Array member 3 serial number 00020A - 00020D
Array member 3 expected unit address 00020E - 000211
Array member 3 current unit address 000212 - 000215
Array member 4 type 000216 - 000219
Array member 4 serial number 00021A - 00021D
Array member 4 expected unit address 00021E - 000221
Array member 4 current unit address 000222 - 000225
Array member 5 type 000226 - 000229
Array member 5 serial number 00022A - 00022D
Array member 5 expected unit address 00022E - 000231
Array member 5 current unit address 000232 - 000235
Array member 6 type 000236 - 000239
Array member 6 serial number 00023A - 00023D
Array member 6 expected unit address 00023E - 000241
Array member 6 current unit address 000242 - 000245
Array member 7 type 000246 - 000249
Array member 7 serial number 00024A - 00024D
Array member 7 expected unit address 00024E - 000251
Array member 7 current unit address 000252 - 000255
Array member 8 type 000256 - 000259
Array member 8 serial number 00025A - 00025D
Array member 8 expected unit address 00025E - 000261
Array member 8 current unit address 000262 - 000265
Array member 9 type 000266 - 000269
Array member 9 serial number 00026A - 00026D
Array member 9 expected unit address 00026E - 000271
Array member 9 current unit address 000272 - 000275
Table 5. Format 03
Description Hex offset
Current I/O card type 0001C6 - 0001C7
Current I/O card serial number 0001CA - 0001CD
Current cache type 0001CE - 0001CF
Current cache serial number 0001D2 - 0001D5
Expected I/O card type 0001D6 - 0001D7
Expected I/O card serial number 0001DA - 0001DD
Expected cache type 0001DE - 0001DF
Expected cache serial number 0001E2 - 0001E5
Table 6. Format 04
Description Hex offset
Array member 10 type 0001B6 - 0001B9
Array member 10 serial number 0001BA - 0001BD
Array member 10 expected unit address 0001BE - 0001C1
Array member 10 current unit address 0001C2 - 0001C5
Array member 11 type 0001C6 - 0001C9
Array member 11 serial number 0001CA - 0001CD
Array member 11 expected unit address 0001CE - 0001D1
Array member 11 current unit address 0001D2 - 0001D5
Array member 12 type 0001D6 - 0001D9
Array member 12 serial number 0001DA - 0001DD
Array member 12 expected unit address 0001DE - 0001E1
Array member 12 current unit address 0001E2 - 0001E5
Array member 13 type 0001E6 - 0001E9
Array member 13 serial number 0001EA - 0001ED
Array member 13 expected unit address 0001EE - 0001F1
Array member 13 current unit address 0001F2 - 0001F5
Array member 14 type 0001F6 - 0001F9
Array member 14 serial number 0001FA - 0001FD
Array member 14 expected unit address 0001FE - 000201
Array member 14 current unit address 000202 - 000205
Array member 15 type 000206 - 000209
Array member 15 serial number 00020A - 00020D
Array member 15 expected unit address 00020E - 000211
Array member 15 current unit address 000212 - 000215
Array member 16 type 000216 - 000219
Array member 16 serial number 00021A - 00021D
Array member 16 expected unit address 00021E - 000221
Array member 16 current unit address 000222 - 000225
Array member 17 type 000226 - 000229
Array member 17 serial number 00022A - 00022D
Array member 17 expected unit address 00022E - 000231
Array member 17 current unit address 000232 - 000235
Table 7. Format 11
Description Hex offset
SCSI sense data 0001C4 - 0001E3
Worldwide ID of device with problem 0001E4 - 001EB
Unit address of device with problem 0001EC - 0001EF
SCSI command descriptor block 0001F4 - 000203
Problem description 000204 - 000223
Table 8. Format 12
Description Hex offset
Current I/O card type and model 0001C4 - 0001CB
Current I/O card serial number 0001CC - 0001D3
Current I/O card worldwide ID 0001D4 - 0001DB
Current cache type and model 0001DC - 0001E3
Current cache serial number 0001E4 - 0001EB
Current cache worldwide ID 0001EC - 0001F3
Previous I/O card type and model 0001FC - 000203
Previous I/O card serial number 000204 - 00020B
Previous I/O card worldwide ID 00020C - 000213
Previous cache type and model 000214 - 00021B
Previous cache serial number 00021C - 000223
Previous cache worldwide ID 000224 - 00022B
Table 9. Format 13
Description Hex offset
Device errors detected 0001FC - 0001FF
Device errors logged 000200 - 000203
Device 1 type 000204 - 000207
Device 1 serial number 000208 - 00020F
Device 1 worldwide ID 000210 - 000217
Device 1 unit address 000218 - 00021B
New device 1 type 00021C - 00021F
New device 1 serial number 000220 - 000227
New device 1 worldwide ID 000228 - 00022F
Device 1 IOA type and model 000230 - 000237
Device 1 IOA serial number 000238 - 00023F
Device 1 IOA worldwide ID 000240 - 000247
Device 1 cache type and model 000248 - 00024F
Device 1 cache serial number 000250 - 000257
Device 1 cache worldwide ID 000258 - 00025F
Device 2 type 000260 - 000263
Device 2 serial number 000264 - 00026B
Device 2 worldwide ID 00026C - 000273
Device 2 unit address 000274 - 000277
New device 2 type 000278 - 00027B
New device 2 serial number 00027C - 000283
New device 2 worldwide ID 000284 - 00028B
Device 2 IOA type and model 00028C - 000293
Device 2 IOA serial number 000294 - 00029B
Device 2 IOA worldwide ID 00029C - 0002A3
Device 2 cache type and model 0002A4 - 0002AB
Device 2 cache serial number 0002AC - 0002B3
Device 2 cache worldwide ID 0002B4 - 0002BB
Device 3 type 0002BC - 0002BF
Device 3 serial number 0002C0 - 0002C7
Device 3 worldwide ID 0002C8 - 0002CF
Device 3 unit address 0002D0 - 0002D3
New device 3 type 0002D4 - 0002D7
New device 3 serial number 0002D8 - 0002DF
New device 3 worldwide ID 0002E0 - 0002E7
Device 3 IOA type and model 0002E8 - 0002EF
Device 3 IOA serial number 0002F0 - 0002F7
Device 3 IOA worldwide ID 0002F8 - 0002FF
Device 3 cache type and model 000300 - 000307
Device 3 cache serial number 000308 - 00030F
Device 3 cache worldwide ID 000310 - 000317
Table 10. Format 14
Description Hex offset
RAID number 000204 - 00020B
Array member 0 type 00020C - 00020F
Array member 0 serial number 000210 - 000217
Array member 0 worldwide ID 000218 - 00021F
Array member 0 expected unit address 000220 - 000223
Array member 0 current unit address 000224 - 000227
Array member 1 type 000228 - 00022B
Array member 1 serial number 00022C - 000233
Array member 1 worldwide ID 000234 - 00023B
Array member 1 expected unit address 00023C - 00023F
Array member 1 current unit address 000240 - 000243
Array member 2 type 000244 - 000247
Array member 2 serial number 000248 - 00024F
Array member 2 worldwide ID 000250 - 000257
Array member 2 expected unit address 000258 - 00025B
Array member 2 current unit address 00025C - 00025F
Array member 3 type 000260 - 000263
Array member 3 serial number 000264 - 00026B
Array member 3 worldwide ID 00026C - 000273
Array member 3 expected unit address 000274 - 000277
Array member 3 current unit address 000278 - 00027B
Array member 4 type 00027C - 00027F
Array member 4 serial number 000280 - 000287
Array member 4 worldwide ID 000288 - 00028F
Array member 4 expected unit address 000290 - 000293
Array member 4 current unit address 000294 - 000297
Array member 5 type 000298 - 00029B
Array member 5 serial number 00029C - 0002A3
Array member 5 worldwide ID 0002A4 - 0002AB
Array member 5 expected unit address 0002AC - 0002AF
Array member 5 current unit address 0002B0 - 0002B3
Array member 6 type 0002B4 - 0002B7
Array member 6 serial number 0002B8 - 0002BF
Array member 6 worldwide ID 0002C0 - 0002C7
Array member 6 expected unit address 0002C8 - 0002CB
Array member 6 current unit address 0002CC - 0002CF
Array member 7 type 0002D0 - 0002D3
Array member 7 serial number 0002D4 - 0002DB
Array member 7 worldwide ID 0002DC - 0002E3
Array member 7 expected unit address 0002E4 - 0002E7
Array member 7 current unit address 0002E8 - 0002EB
Array member 8 type 0002EC - 0002EF
Array member 8 serial number 0002F0 - 0002F7
Array member 8 worldwide ID 0002F8 - 0002FF
Array member 8 expected unit address 000300 - 000303
Array member 8 current unit address 000304 - 000307
Array member 9 type 000308 - 00030B
Array member 9 serial number 00030C - 000313
Array member 9 worldwide ID 000314 - 00031B
Array member 9 expected unit address 00031C - 00031F
Array member 9 current unit address 000320 - 000323
Array member 10 type 000324 - 000327
Array member 10 serial number 000328 - 00032F
Array member 10 worldwide ID 000330 - 000337
Array member 10 expected unit address 000338 - 00033B
Array member 10 current unit address 00033C - 00033F
Array member 11 type 000340 - 000343
Array member 11 serial number 000344 - 00034B
Array member 11 worldwide ID 00034C - 000353
Array member 11 expected unit address 000354 - 000357
Array member 11 current unit address 000358 - 00035B
Array member 12 type 00035C - 00035F
Array member 12 serial number 000360 - 000367
Array member 12 worldwide ID 000368 - 00036F
Array member 12 expected unit address 000370 - 000373
Array member 12 current unit address 000374 - 000377
Array member 13 type 000378 - 00037B
Array member 13 serial number 00037C - 000383
Array member 13 worldwide ID 000384 - 00038B
Array member 13 expected unit address 00038C - 00038F
Array member 13 current unit address 000390 - 000393
Array member 14 type 000394 - 000397
Array member 14 serial number 000398 - 00039F
Array member 14 worldwide ID 0003A0 - 0003A7
Array member 14 expected unit address 0003A8 - 0003AB
Array member 14 current unit address 0003AC - 0003AF
Array member 15 type 0003B0 - 0003B3
Array member 15 serial number 0003B4 - 0003BB
Array member 15 worldwide ID 0003BC - 0003C3
Array member 15 expected unit address 0003C4 - 0003C7
Array member 15 current unit address 0003C8 - 0003CB
Array member 16 type 0003CC - 0003CF
Array member 16 serial number 0003D0 - 0003D7
Array member 16 worldwide ID 0003D8 - 0003DF
Array member 16 expected unit address 0003E0 - 0003E3
Array member 16 current unit address 0003E4 - 0003E7
Array member 17 type 0003E8 - 0003EB
Array member 17 serial number 0003EC - 0003F3
Array member 17 worldwide ID 0003F4 - 0003FB
Array member 17 expected unit address 0003FC - 0003FF
Array member 17 current unit address 000400 - 000403
Table 11. Format 17
Description Hex offset
Associated IOA type and model 0001C4 - 0001CB
Associated IOA serial number 0001CC - 0001D3
Associated IOA worldwide ID 0001D4 - 0001DB
Type of adapter connection (1 = Dual storage IOA pair, 2 = Storage IOA to auxiliary cache) 0001DC - 0001DC
Problem description 0001E0 - 00021F
Table 12. Format 20
Description Hex offset
Problem description 0001C4 - 000203
Path 1 adapter port 00020A
Path active (00 = Unknown, 01 = Yes, 10 = No, 11 = Unknown) 00020D, bit 0 - 1
Path state (0000 = Unknown, 0001 = Operational, 0010 = Degraded, 0011 = Failed) 00020D, bit 4 -7
Node 1 port type (0000 = Empty, 0001 = Adapter, 0010 = Expander, 0011 = Device, 0100= LUN) 000210, bit 0 - 3
Node 1 status (0000 = Operational, 0001 = Degraded, 0010 = Failed, 0011 = Suspect, 0100 = Missing, 0101 = Not valid) 000210, bit 4 - 7
Node 1 phy 000212
Node 1 information (1000 = 1.5 Gbps, 1001 = 3.0 Gbps) 000213, bit 4 - 7
Path 1 node 1 SAS address 000214 - 00021B
Additional nodes are self defining  


Send feedback Rate this page