Perform these procedures to close serviceable events, clear
hardware messages, and prepare the server to return to the customer.
Follow this checklist before performing the procedure:
- Record the system reference code
(SRC), or symptom, and the location code of the field-replaceable
unit (FRU) you replaced, for future reference. Is the server managed
by a management console?
- Yes: Continue with the next step.
- No: Do one of the following steps:
|
- On the Hardware Management Console
(HMC), open Manage Serviceable Events and examine
the service action event log for any open service action events.
- Are any service action events
open?
- Yes: Continue with the next step.
- No: If the system attention LED is still on, turn off the
LED as described in Activating and deactivating LEDs. Return
the system to the customer. This completes the repair.
|
- Record the list of open service
action events.
- From the list of serviceable
events recorded in step 4, complete
the following steps 6 -
step 32 for
each open service action event.
- Determine the error class of
the serviceable event. Record for future use.
- Examine the details of the open
service action event.
Is the error code that is associated with
this service action event the same as recorded in step 1?
|
- Yes: Go to step 11.
- No: Continue with the next step.
|
- Examine the FRU list of the service
action event. Are any FRUs listed for the service action event?
- Yes: Continue with the next step.
- No: Go to step 11.
|
- Is the FRU list identical that
is, the same FRUs, same number of FRUs, and same order of FRUs) to
the FRU list of the error code recorded in step 1?
- Yes: Go to step 11.
- No: Continue with the next step.
|
- The FRU list is different. Is
the FRU you replaced and recorded in step 1 in the list
of FRUs for this service action event?
- Examine the details of this
service action event, and record the partitions involved in this service
action event for use in a later step.
- Is the error code associated
with this service action event of the form A11-xxx or A01-xxx?
- Yes: Continue with the next step.
- No: Go to step 17.
|
- Have you begun a list of Axx partitions
from prior service action events that you processed in this MAP?
- Yes: Go to step 15.
- No: Continue with the next step.
|
- Begin a new list of Axx partitions
by copying the list of partitions obtained in step 11. Go to step 16.
- Add the partition list obtained
in step 11 to
the existing list of Axx partitions obtained from
processing previous service action events in this maintenance analysis
procedure (MAP).
- Remove all entries in the list
of all partitions you recorded in step 11. If you are
referred to the list of partitions obtained in step 11 in future
steps, the list is empty. Go to step 17.
- Select and highlight the service
action event from the Error Associated With This Serviceable Event
window.
- Click Close Event.
- Add comments for the serviceable
event. Include any unique additional information. Click OK.
The following steps will add or update FRU information.
- Did you replace, add, or modify
a FRU of the open service action event?
- Yes: Continue with the next step.
- No: Go to step 22.
|
- From the FRU list, select a
FRU that you need to update. Double-click the FRU, and update the
FRU information. Go to step 23.
- Select the No FRU Replaced
for this Serviceable Event option.
- Click OK to close the
service action event.
- Is the list of all partitions
you recorded in step 11 empty?
- Yes: Go to step 32.
- No: Continue with the next step.
|
- Does the list of all partitions
you recorded in step 11 contain more
than one entry?
- Yes: Continue with the next step.
- No: Go to step 32.
|
- Is the
error class recorded in step 25 AIX?
- Yes: Continue with the next step.
- No: Go to step 32.
|
- Perform all the following steps
for each entry in the list of all partitions you recorded in step 11, except for
the partition you were using to debug the original problem.
- From the list of all partitions,
open the HMC virtual terminal window of a partition, and then type diag at
the AIX command
prompt.
- When the diagnostic operating
instructions are displayed, complete the following steps:
- Press Enter.
- Select the Task Selection option.
- Select the Log Repair option.
- Select the resource associated with the repair action:
- If the repair action was reseating a cable or adapter, select
the resource associated with that repair action.
- If the resource associated with your repair action is not displayed
on the Resource List, select sysplanar0.
- Click Commit after you make your selection.
Note: If the terminal type is not defined, you are prompted
to define it before you can proceed.
|
- Exit from diagnostics in this
partition and return to the AIX command prompt.
- Have all the partitions in the
list of all the partitions you recorded in step 11 been processed?
- Yes: Continue with the next step.
- No: Go to step 24 to process
the next partition in the list you recorded in step 11.
|
- Have all the serviceable events
recorded in step 4 been
processed?
- Yes: Continue with the next step.
- No: Go to step 5 and process
the next service action event in the list of serviceable events recorded
in step 4.
|
- While processing all service
action events, were you directed to step 14?
- Yes: Continue with the next step.
- No: If the system attention LED is still on, turn off the
LED as described in Activating and deactivating LEDs. Return
the system to the customer. This completes the repair.
Note: If,
during the processing of the list of open service action events, some
service action events remained open, further service actions might
be required to complete the repair.
|
- Perform all the following steps
for each entry in the list of Axx partitions you
began recording in step 14, except for
the partition you were using to debug the original problem.
- From the list of Axx partitions,
open the management console virtual
terminal window of a partition , and then type diag at
the AIX command
prompt.
- When the diagnostic operating
instructions are displayed, complete the following steps:
- Press Enter.
- Select the Task Selection option.
Note: If the terminal
type is not defined, you are prompted to define it before you can
proceed.
- Select the resource associated with the repair action:
- If the repair action was reseating a cable or adapter, select
the resource associated with that repair action.
- If the resource associated with your repair action is not displayed
on the Resource List, select sysplanar0.
- Click Commit after you make your selection.
|
|
- Exit from diagnostics in this
partition and return to the AIX command prompt.
- Have all the partitions in the
list of Axx partitions you began recording in step 14 been processed?
- Yes: Continue with the next step.
- No: Go to step 34 to process
the next partition in the list you recorded in step 14.
|
- If the system attention LED is still on, turn
off the LED as described in Activating and deactivating LEDs. This
completes the repair. Return the system to the customer.
Note: If,
during the processing of the list of open service action events, some
service action events remained open, further service actions might
be required to complete the repair.