Use this MAP to resolve the following problem:
Configuration error: incorrect connection between cascaded enclosures (SRN nnnn-4010) for a PCIe2 or a PCIe3 controller.
Detail Data
PROBLEM DATA
0001 0800 1910 00F0 0408 0100 0101 0000 0150 003E 0000 0030 57B5 4100 0000 0001
0004 FFFF FFFF FFFF 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0004 AA98 ^
|
Resource is 0004FFFF
Using the resource found in step 2, see SAS resource locations to understand how to identify the controller's port to which the device, or device enclosure, is attached.
For example, if the resource is 0004FFFF, port 04 on the adapter is used to attach the device or device enclosure that is experiencing the problem.
Review the device enclosure cabling and correct the cabling as required. To see examples of device configurations with SAS cabling, see Serial attached SCSI cable planning.
If unsupported device enclosures are attached, then either remove or replace them with supported device enclosures.
When the problem is resolved, see the removal and replacement procedures topic for the system unit on which you are working and do the "Verifying the repair" procedure.