POWER7 information
MEMORY
Use this topic to view memory and location information for the 2890 and 2892 Integrated xSeries Server (IXS) cards.
Memory for 2890 Integrated xSeries Server (IXS) card
Figure 1. Locations of DIMM 0, DIMM 1, DIMM 2 and DIMM 3 on 2890 Integrated xSeries Server (IXS) card.

One of the Pentium memory modules (DIMM 0, DIMM 1, DIMM 2, or DIMM 3) might be the failing item (see Finding parts, locations, and addresses).
| Feature | Size |
|---|---|
| 2795/2895 | 128 MB |
| 2796/2896 | 256 MB |
| 2797/2897 | 1 GB |
Notes:
- At least 1 Pentium memory module is required in positions DIMM 0, DIMM 1, DIMM 2 or DIMM 3.
- An IXS adapter card IOP (see Finding parts, locations, and addresses) is required in the IOP DIMM position. This IOP memory module is not interchangeable with the Pentium memory modules in positions DIMM 0, DIMM 1, DIMM 2 or DIMM 3.
Memory for 2892 Integrated xSeries Server (IXS) card
Figure 2. Locations of DIMM 0, DIMM 1, DIMM 2 and DIMM 3 on 2892 Integrated xSeries Server (IXS) card

One of the Pentium memory modules (DIMM 0, DIMM 1, DIMM 2, or DIMM 3) might be the failing item (see Finding parts, locations, and addresses).
| Feature | Size |
|---|---|
| 0426/0446 | 512 MB |
| 0427/0447 | 1 GB |
Note: At least two Pentium memory
modules are required in positions DIMM 0 and DIMM 1, or positions
DIMM 2 and DIMM 3.