The system has detected an error with the FSI path.
- Replace the processor modules one at a time
(Un-P1-C11, then Un-P1-C10 if
present). See System FRU locations for
information about locating the FRU.
Power on the system to the hypervisor
standby.
Note: Slow boot is not supported.
Does
the problem persist? - No:
- This ends the procedure.
- Yes:
- Continue with the next step.
- Have all processor modules been replaced?
- No:
- Go back to step 1 and
replace another processor module.
- Yes:
- Continue with the next step.
- Replace the system backplane (Un-P1).
Power on the system to the hypervisor
standby.
Note: Slow boot is not supported.
This
ends the procedure.