FSPSP07

The time of day has been reset to the default value.

  1. To set the time of day, see the systems operations guide.
  2. If the problem persists, perform the following steps:
    1. Power off the system. See Powering on and powering off the system .
    2. To determine the action to perform, use the following table.
      System Action

      8246-L1C, 8246-L1D, 8246-L1S, 8246-L1T, 8246-L2C, 8246-L2D, 8246-L2S, or 8246-L2T

      Replace the time-of-day battery at location Un-P1-E1. See System FRU locations.
  3. To determine the action to perform, use the following table.

    System:

    Action:

    8246-L1C, 8246-L1D, 8246-L1S, 8246-L1T, 8246-L2C, 8246-L2D, 8246-L2S, or 8246-L2T

    Power on the system to the hypervisor standby.
    Note: Slow boot is not supported.
    This ends the procedure.