Function Code L: Load/Unload Test
Function Code L tests the drive’s ability to
load and unload a tape cartridge. This test runs 10 loops at approximately
15 seconds per loop.
Press the Unload Button to stop the diagnostics and exit maintenance mode. Pressing the Unload Button once will stop the test at the end of the current test loop. Pressing the Unload Button twice will stop the test immediately. Wait for the drive to rewind the tape and unload the cartridge.
Attention: Even though no data is written during this
test, it is recommended that you use a blank (scratch) cartridge for
this test.
- Place the drive in Maintenance Mode. For instructions, see Entering Maintenance Mode.
- Press the Unload Button once per second until
Lappears in the SCD. (If you cycle past the code that you want, press the Unload Button once per second until the code reappears.) - Press and hold the Unload Button for three or more seconds, then
release it to select the function. The SCD changes to a flashing
C. - Insert a scratch (blank) data cartridge. The SCD changes to a
flashing
L. The tape drive runs the tests.- If no error is detected, the diagnostics will loop and begin again.
To stop the loop, press the Unload Button for one second and release.
When the loop ends,
0temporarily appears in the SCD. - If an error is detected, the Status LED flashes amber and the drive posts an error code to the SCD. To determine the error, locate the code in Error Codes and Messages. To clear the error either turn the power off and then on again, or reboot the drive by pressing and holding the Unload Button for 10 seconds.
- If no error is detected, the diagnostics will loop and begin again.
To stop the loop, press the Unload Button for one second and release.
When the loop ends,