TS7620 Appliance Express® ProtecTIER Parts list and hardware component replacement
Before you service the TS7620, familiarize yourself with the chassis and hardware component layout.
Before you begin, take time to review the following information:
- About the TS7620 hardware
- Powering-on the server
- Electrostatic discharge procedure
- How to verify a hardware fault before you service the component by running a Health check through the ProtecTIER Service menu. Go to Choosing Health Monitoring or through ProtecTIER® Manager Hardware resources.
- How to verify a hardware fault before you service the component through the ProtectIER Hardware resources. Go to the Figure 5
The TS7620 (SM2) supports either VTL or FSI depending on the servers hardware configuration.
- Customer replaceable unit (CRU) versus field replaceable unit (FRU)
- Components that can safely and easily be self-serviced by the customer are CRU components. Components for which removal and replacement requires a higher degree of technical expertise and system knowledge are FRU components, and are to be serviced by IBM personnel, only.
- Internal versus External
- Internal components are located inside the server chassis, and are accessible only if the servers top cover is removed. External components are accessible with the servers cover in place.
- Hot-swappable versus Cold-swappable
- Hot-swappable components do not require stopping input/output
(I/O) activity or disconnecting the server from A/C power before you
remove or replace the component. Cold-swappable components cannot
be removed or replaced while the system is running. I/O must be stopped
and the server must be disconnected from the A/C power source before
removal or replacement is started.Attention: Failure to adhere to these guidelines might result in component or system damage, data loss, or personal injury.
- FRU ID
- Each component has a unique FRU ID (part number). The customer
schedules a service call for a FRU and provides the FRU ID to you,
the IBM customer support representative.Note: The FRU IDs in this table might become outdated after this document is produced. It is suggested that you first try to locate FRU IDs through one of the resources that are discussed in Interpreting TS7620 Appliance Express ProtecTIER V3.4.1 hardware alerts.
Failure to follow the guidelines and procedures in the mentioned sections might result in component or system damage or personal injury.
- The VTL version is the only ProtecTIER 3959 server that has a Fibre Channel, Emulex HBA.
- The VTL version is the only ProtecTIER 3959 server that has one Intel Dual-port Ethernet adapter.
- The FSI versions of the ProtecTIER server has two Intel Dual-port Ethernet adapters.
- The FSI versions of the ProtecTIER server has a Quad-port Ethernet adapter.
| Component name / hardware name if listed in the ProtecTIER Manager GUI Hardware Resources view | Quantity | CRU | FRU | Internal | External | Hot-swappable | Cold-swappable | FRU ID (Part number) |
|---|---|---|---|---|---|---|---|---|
| Quad Port Ethernet adapter that is installed in the SM2 FSI base unit for replication | 1 | ▪ | ▪ | ▪ | 94Y5167 | |||
| CMOS coin battery | 1 | ▪ | ▪ | 33F8354 | ||||
| 2 TB 3.5” SAS hard disk drives (HDDs) or Disk drive | 12 | ▪ | ▪ | ▪ | 00AT302 (Software Version 3.3.6 and above) | |||
| 2 TB 3.5” SAS hard disk drives (HDDs) or Disk drive | 12 | ▪ | ▪ | ▪ | 35P2313 (all versions of software) | |||
| Power supply units (PSUs) or Power supply | 2 | ▪ | ▪ | ▪ | 98Y3253 | |||
| Cooling fans or Cooling module | 10 | ▪ | ▪ | ▪ | 45W8018 | |||
| BBU (RAID) replacement battery kit (iBBU08) | 1 | ▪ | ▪ | ▪ | 35P2359 | |||
| DIMM (8 GB Dual in-line memory modules or Memory module | 6 | ▪ | ▪ | ▪ | 35P1121 | |||
| USB Drive (portable DVD drive) | 1 | ▪ | ▪ | ▪ | 38L6964 | |||
Intel Dual-port Ethernet adapter -
|
1 or 2 | ▪ | ▪ | ▪ | 94Y5166 | |||
| Fibre Channel, Emulex HBA- only VTL SM2 | 1 | ▪ | ▪ | ▪ | 42D0500 | |||
| LSI MegaRAID SAS9280-4i4e (Repository RAID) or SAS Expander | 1 | ▪ | ▪ | ▪ | 35P1368 | |||
| LSI MegaRAID SAS9240-4i (Boot RAID) or RAID card | 1 | ▪ | ▪ | 35P1369 | ||||
| Seagate 500 GB SFF 2.5” SATA (internal boot drives) or Boot drive | 2 | ▪ | ▪ | ▪ | 35P1193 | |||
| Micron 480 GB 2.5” SSD (internal boot drives) or Boot drive | 2 | ▪ | ▪ | ▪ | 00VJ414 | |||
| 3959 SM2 MECH ASM (chassis, SAS EXPANDER CARD, ONBOARD ETH CARD, and CPU) or CPU, SAS Expander, Ethernet port (On board) | 1 | ▪ | ▪ | ▪ | ▪ | 00V6991 | ||
| Power cable - do not use the wire bail if it does not fit over the cable. | 2 | ▪ | ▪ | ▪ | 46X6880 | |||
| Boot CAGE (Dual Boot Drive Cage Assembly) | 1 | ▪ | ▪ | ▪ | 35P1190 | |||
| Base Unit Shelf Assembly kit | 1 | ▪ | ▪ | ▪ | 35P4935 | |||
| AIRDUCT, Air Flow (plastics, 2 parts) | 1 | ▪ | ▪ | ▪ | 35P1191 | |||
| RAID-SAS Expander mini-SAS cable | 1 | ▪ | ▪ | ▪ | 00V7085 | |||
| Boot Drive SAS Cable | 1 | ▪ | ▪ | ▪ | 00V7085 | |||
| Slide Rails for Tray (No Screws) | 1 | ▪ | ▪ | ▪ | 69Y5085 | |||
| Cable Management Arm | 1 | ▪ | ▪ | ▪ | 49Y4817 |
| Component name / hardware name if listed in the ProtecTIER Manager GUI Hardware Resources view | Quantity | CRU | FRU | Internal | External | Hot-swappable | Cold-swappable | FRU ID (Part number) |
|---|---|---|---|---|---|---|---|---|
| PWR SUPPLY and Power Cooling Module/Power supply (99Y1243) or Cooling module (45W8018) | 2 | ▪ | ▪ | ▪ | 00AR038 | |||
| CABLE - SAS 1x to 2x | 1 | ▪ | ▪ | ▪ | 35P2255 | |||
| HARD DRIVE - carrier with HDD or Disk drive | 12 | ▪ | ▪ | ▪ | 00AT302 | |||
| HARD DRIVE - carrier with HDD or Disk drive | 12 | ▪ | ▪ | ▪ | 35P2313 | |||
| CHASSIS (the chassis base assembly includes the SAS Expander (35P2384)) | 1 | ▪ | ▪ | ▪ | 35P3465 | |||
| Tivoli Event Services Manager (Enclosure SAS module) Canister or Canister | 2 | ▪ | ▪ | ▪ | 35P2384 | |||
| CABLE POWER (2.8 M IEC 320-C13) | 2 | ▪ | ▪ | ▪ | 46X2536 | |||
| CABLE POWER (2.8 M NEMA C-13) | 2 | ▪ | ▪ | ▪ | 46X6880 | |||
| RAIL KIT (Rail kit for EXP) | 1 | ▪ | ▪ | ▪ | 00AR076 | |||
| SAS CABLE 1 to 1 | 2 | ▪ | ▪ | ▪ | 44V4041 |
A hardware fault can occur on a component that is one of a set, as in the case of the HDDs (hard disk drives), PSUs (power supply units), or cooling fans. In this case, you must isolate the specific component (for example, HDD 5) that generated the fault, and diagnose the cause and severity of the problem. Refer to the following figures to see how the HDDs, cooling fans, adapters, DIMMs, and PSUs are arranged and numbered. In the case of the DIMMs, only six of the eight slots (A1, A2, B1, B2, C1, and D1) are used. Slots C2 and D2 are left empty.
- 1: cooling fans
- 2: boot drive assembly
- 3: sysplanar
- 4: pci card adapters
- 5: power supplies
- 6: SAS expander




| P2 Power supply 2 | 7 RAID Battery Backup Unit (BBU) |
| P1 Power supply 1 | 6 ETH0 (Act/Link A) port: LAN ETH1 (Act/Link B) port: Replication |
| S RS-232 serial port | 5 Fibre Channel adapter |
| V Video port | 4 Unused (Empty) |
| ETH2 (A1) on-board (Port 0) Ethernet port: Replication | 3 Boot Drive MegaRAID Controller |
| ETH3 (A2) on-board (Port 1) Ethernet port: LAN | 2 Unused (Empty) |
| U USB ports: Upper left = 1, upper right = 2, lower left = 3, lower right = 4 | 1 SAS Expander (for expansion units) |
| P2 Power supply 2 | 7 RAID Battery Backup Unit (BBU) |
| P1 Power supply 1 | 6 ETH0 (Act/Link A) port: LAN ETH1 (Act/Link B) port: Replication |
| S RS-232 serial port | 5 ETH2 (Act/Link A) port: FSI ETH3 (Act/Link B) port: FSI |
| V Video port | 4 ETH4 (Act/Link A) port: replication ETH5 (Act/Link B) port: replication ETH6 (Act/Link C) port: replication ETH7 (Act/Link D) port: replication |
| ETH4 (A1) On-board (Port 0) Ethernet port: Replication | 4 Unused (Empty) |
| ETH5 (A2) On-board (Port 1) Ethernet port: LAN | 3 Boot Drive MegaRAID Controller |
| U USB ports: Upper left = 1, upper right = 2, lower left = 3, lower right = 4 | 2 Unused (Empty) |
| 1 SAS Expander (for expansion units) |