DS8000 Service Documentation Version 8.5.1

BE1xxxxx

This section lists the BE1xxxxx system reference codes.

If the SRC listed in a serviceable event is missing from the following table, ask your next level of support for assistance.
Note: Next level, inform development of any SRCs not defined in the table.
Table 1. BE11xxxx system reference codes
System reference code Description
BE110000 Boot DDM error, hdisk0.
BE110001 Boot DDM error, hdisk1.
BE111002 FHD DDM error, hdisk0.
BE111003 FHD DDM error, hdisk1.
BE111032 The server partition Ethernet is not configured properly.
BE111050 The server partition hard disk drives are not mirrored.
BE111051 One server partition hard disk drive has failed.
BE111052 The server partition dual hard disk drives mirror operation failed.
BE111053 The server partition dual hard disk drives unmirror operation failed.
BE111056 The server partition dual hard disk drives are not installed in correct drive slots.
BE111057 The capacity of the replacement hard disk drive is less than the expected capacity.
BE111058 The server partition dual hard disk drives mirroring cleanup operation failed.
BE111059 A server partition filesystem is full.
BE11105A An illegal server partition dual hard disk drive operation was attempted.
BE11105B The server partition dual hard disk drive command failed.
BE11105C The mirrored server partition dual hard disk drives cannot be synchronized.
BE11105D The server partition dual hard disk drives boot image command failed.
BE11105F One server partition hard disk drive has failed. The other disk file system is not synchronized.
BE111060 The server partition IMLs from the second hard disk drive from the bootlist.
BE11106F The server partition FHD is missing.
BE111070 AIX file system corruption detected on boot disk
BE11D000 Unrecoverable FHD disk error.
BE11D001 FHD disk missing.
BE11D002 FHD image header missing.
BE11D004 FHD fhdp code detected discrepancy.
BE11D005 FHD heartbeat failure.
BE11D007 FHD - OS unable to register for EPOW3.
BE11D00B FHD - image invalidation successful.
BE11D017 FHD write error, I/O error.
BE11D018 FHD write error, write operation was interrupted.
BE11D019 FHD write error, hang-up occurred or nonexistent devices.
BE11D01A FHD write error, user or group quota of disk blocks exhausted.
BE11D01B FHD write error, file descriptor parameter does not specify valid file descriptor open for writing.
BE11D01C FHD write error, invalid parameter value.
BE11D01D FHD write error, O_NONBLOCK is set and process would be delayed in write operation.
BE11D01E FHD write error, memory pointer is out of allocated address space.
BE11D01F FHD write error, no free space left on file system.
BE11D020 FHD write error, offset greater than MAX_FILESIZE was requested.
BE11D021 FHD write error, attempt to write made to unopened file, pipe, or FIFO or an unconnected socket.
BE11D022 FHD write error, file descriptor is associated with a pipe or FIFO.
BE11D023 FHD write error, transfer request size outside range supported by the STREAMS file.
BE11D024 FHD read error, I/O error.
BE11D025 FHD read error, read was interrupted before any data received.
BE11D026 FHD read error, request to nonexistent device or outside capabilities of device.
BE11D027 FHD read error, message contains control port.
BE11D028 FHD read error, bad file descriptor parameter.
BE11D029 FHD read error, invalid parameter value.
BE11D02A FHD read error, no data ready to be read.
BE11D02B FHD read error, memory pointer is out of address space.
BE11D02C FHD read error, calling process slept while read region lockec.
BE11D02D FHD read error, offset greater than MAX_FILESIZE.
BE11D02E FHD read error, analysis overflow.
BE11D02F FHD read error, file descriptor is associated with a pipe or FIFO.
BE11D030 FHD lseek error, bad file descriptor parameter.
BE11D031 FHD lseek error, file descriptor is associated with a pipe or FIFO.
BE11D032 FHD lseek error, invalid parameter value.
BE11D033 FHD lseek error, offset overflow.
BE11D034 FHD open error, I/O error.
BE11D035 FHD open error, open was interrupted.
BE11D036 FHD open error, request to nonexistent device or outside capabilities of device.
BE11D037 FHD open error, user or group quota of disk blocks has been exhausted.
BE11D038 FHD open error, named file exists.
BE11D039 FHD open error, invalid parameter value.
BE11D03A FHD open error, file is locked.
BE11D03B FHD open error, path parameter points outside allocated memory space.
BE11D03C FHD open error, directory cannot be extended.
BE11D03D FHD open error, file exceeds max file size.
BE11D03E FHD open error, overflow of max file size.
BE11D03F FHD open error, access denied.
BE11D040 FHD open error, file is directory and write access if required.
BE11D041 FHD open error, system limit for open file descriptors per process reached.
BE11D042 FHD open error, path parameter exceeds system limit.
BE11D043 FHD open error, system file table is full.
BE11D044 FHD open error, invalid parameter value.
BE11D045 FHD open error, system unable to allocate resources.
BE11D046 FHD open error, system cannot allocate STREAM.
BE11D047 FHD open error, component of path is not a directory.
BE11D048 FHD open error, file is on read-only system, need write access.
BE11D049 FHD open error, file is busy.
BE11D04A FHD open error, too many symbolic links encountered in path.
BE11D050 FHD write error, unknown suberror type.
BE11D051 FHD read error, unknown suberror type.
BE11D052 FHD lseek error, unknown suberror type.
BE11D053 FHD open error, unknown suberror type.
BE11D054 FHD - server to be fenced due to lack of FHD disks to have FHD ability.
BE11D055 FHD image header error.
BE11D056 FHD - server to be fenced due to image invalidation error.
BE11D05A FHD - fhdp code detected discrepancy or heartbeat failure while in single cluster.
Table 2. BE12xxxx system reference codes
System reference code Description
BE120007 LPAR Network Analysis detected missing interface on the 10 Gb CEC Ethernet Adapter.
BE120008 LPAR network analysis detected connection issues on the black network.
BE120009 LPAR network analysis detected connection issues on the gray network.
BE120010 IBM.essLPARServicesRM detected missing CEC Ethernet adapter resource during harvest.
BE120011 IBM.essLPARServicesRM detected missing CEC Ethernet network port resource during harvest.
BE120020 10 Gb Ethernet card was not found in the expected slot during the 10 Gb Ethernet card install or repair.
Table 3. BE14xxxx system reference codes
System reference code Description
BE1400F6 Keys were recovered after IML. Reason Code=0xF6.
BE1400F7 Unable to read any key repository.Reason Code=0xF7.
BE14CF10 The key servers in a high availability environment detected that the DS8000 attempted to communicate using an unknown device group identifier.
BE14CF11 The key servers in a high availability environment detected that the target DS8000 certificate is not installed on the key servers.
BE14CF12 The DS8000 could not retrieve keys for a non-data-at-rest key group from any of the configured encryption key management servers.
BE14CF13 The DS8000 regained access to a non-data-at-rest key group and successfully retrieved the key.
BE14CFE0 The DS8000 could not retrieve keys from any of the configured encryption key management servers.
BE14CFE1 The DS8000 regained access to customer encryption key management servers. Automatic dual cluster reboot initiated. No further action needed.
BE14CFE3 The DS8000 detected internal key repository error.
BE14CFE5 The DS8000 detected a potential key store corruption and recovered by an automatic reboot of the partitions (LPARs).
BE14CFEA The DS8000 detected that periodic key retrieval failed for one or more configured encryption key management server(s).
BE14CFEB The DS8000 detected less than minimum number of required key servers are configured for periodic key retrieval.
BE14CFEC The DS8000 detected valid recovery key. Dual partitions (LPARs) reboot was initiated to restore machine to operational state. No further action needed.
BE14CFED The DS8000 failed to unwrap key group's key based on a recovery key received from customer.
BE14CFEF The DS8000 detected that customer has not configured recovery key.
BE14CFF0 The DS8000 detected multiple attempts to authenticate or recover dead-locked system with invalid recovery key.
BE14CFF1 The DS8000 detected that user has re-keyed recovery key.
BE14CFF2 The DS8000 detected that the key group recovery key and key group key records are out of sync. Recovery key needs to be re-keyed.
BE14CFF3 The DS8000 was non-responsive during recovery key's RSA key generation process.
BE14CFF4 The DS8000 detected that data integrity check failed after data was stored persistently in the key store.
BE14CFF5 An invalid encryption-capable SFI configuration has been detected. A valid certificate is not installed on the SFI or the SFI does not have a homogenous configuration of encryption-capable drives.
BE14CFF6 DS8000 encryption certificate will expire in 90 days.
BE14CFF7 DS8000 encryption certificate will expire in 60 days.
BE14CFFA DS8000 encryption certificate will expire in 30 days.
BE14CFFB DS8000 encryption certificate will expire in 14 days.
BE14CFFC DS8000 encryption certificate will expire in 7 days.
BE14CFFD DS8000 encryption certificate has expired.
BE14CFFE DS8000 encryption certificate has been updated.
BE14CFFF The DS8000 has detected a lack of redundancy between key servers in a high availability grouping environment.
BE14E004 The DS8000 cannot retrieve encryption keys from the customer's encryption key management server(s) because the DS8000 could not detect any active encryption key management servers. Suspected configuration error.
BE14E008 The DS8000 cannot retrieve encryption keys from the customer's encryption key management server(s) because of communication errors between the DS8000 management console (HMC) and encryption key management servers. A suspected network error.
BE14E009 The DS8000 cannot retrieve encryption keys from the configured encryption key management server because of communication errors between the DS8000 partitions (LPARs) and the management console (HMC).
BE14E00B The DS8000 cannot retrieve encryption keys from the configured encryption key management server. A command timeout has occurred between DS8000 partitions (LPARs) and the management console (HMC).
BE14E011 All configured encryption key management servers are unable to provide the key(s) requested by the DS8000.
BE14E012 The DS8000 cannot unwrap keys received from all configured encryption key management servers.
BE14E013 The DS8000 detected that the data key signature calculated does not match the expected value.
BE14E0F1 The DS8000 cannot access the customer's encryption key management server.
BE14E1F6 The DS8000 partitions (LPARs) were activated without access to the customer's encryption key management servers. Encryption key management key servers are now available and the DS8000 partitions (LPARs) must be re-cycled to allow data access.
BE14E3F7 DS8000 data encryption key repository permanent error. Failure to read record or certificate.
BE14EA0B The DS8000 cannot retrieve encryption keys from some of the encryption key management servers. A command timeout has occurred between DS8000 partitions (LPARs) and the management console (HMC).
BE14EA11 One or more configured encryption key management servers unable to provide the key(s) requested by the DS8000.
BE14EA12 The DS8000 cannot unwrap the group key using a data key received from one or more configured encryption key management servers.
BE14EA13 The DS8000 detected that the data key signature calculated does not match the expected value.
BE14EAF1 The DS8000 has failed to communicate with the encryption key management server. If the communication continues to fail after four hours, a request for service will occur.
BE14EAF2 The DS8000 has failed to communicate with the encryption key management server for four hours.
BE14EAF3 The DS8000 has failed to communicate with the encryption key management server using an SSL link. If the communication continues to fail after four hours, a request for service will occur.
BE14EAF4 The DS8000 has failed to communicate with the encryption key management server for four hours, using an SSL link.
BE14EAF5 The DS8000 reestablished communication with the encryption key management server.
BE14EAF6 The DS8000 has reestablished communication with the encryption key management server by using an SSL link.
Table 4. BE16xxxx System Reference Codes
System Reference Code Description
BE160000 One or more control switch values on one or more partitions have corrupted values.
Table 5. BE17xxxx system reference codes
System reference code Description
BE171000 LPAR statesave or no-warmstart LPAR statesave.
BE172000 LPAR crash save.
BE173000 LPAR config data.
BE175000 PDISK statesave.
BE176000 Enclosure statesave.
BE178000 Solid State Disk (SSD) S.M.A.R.T. data offload
Table 6. BE18xxxx system reference codes
System reference code Description
BE18xxxx Power failure not isolated.
Table 7. BE19xxxx system reference codes
System reference code Description
BE190001 RPC-1 standby 3.3V limiter failure for CEC enclosure 1.
BE190002 RPC-2 standby 3.3V limiter failure for CEC enclosure 1.
BE190003 RPC-1 standby 3.3V limiter failure for CEC enclosure 2.
BE190004 RPC-2 standby 3.3V limiter failure for CEC enclosure 2.
BE190005 RPC-1 is held fenced by RPC-2.
BE190006 RPC-1 to RPC-2 communication failure.
BE190007 RPC-2 is held fenced by RPC-1.
BE190008 RPC-2 to RPC-1 communication failure.
BE190009 RPC-1 to CEC enclosure 1 communication failure.
BE19000A RPC-1 to CEC enclosure 2 communication failure.
BE19000B RPC-2 to CEC enclosure 1 communication failure.
BE19000C RPC-2 to CEC enclosure 2 communication failure.
BE190010 CEC enclosure 1 failed to communicate with RPC-1 and RPC-2.
BE190011 CEC enclosure 2 failed to communicate with RPC-1 and RPC-2.
BE190012 CEC enclosure 1 and 2 failed to communicate with RPC-1.
BE190013 CEC enclosure 1 and 2 failed to communicate with RPC-2.
BE190014 CEC enclosure 1 failed to communicate with RPC-1.
BE190015 CEC enclosure 2 failed to communicate with RPC-1.
BE190016 CEC enclosure 1 failed to communicate with RPC-2.
BE190017 CEC enclosure 2 failed to communicate with RPC-2.
BE190020 RPC-1 interrupt state incorrect.
BE190021 RPC-2 interrupt state incorrect.
BE190030 RPC-1 to RPC-2 communication failure.
BE190031 RPC-1 and RPC-2 failed to communicate with the rack ID logic card.
BE190032 RPC-1 failed to communicate with the rack ID logic card.
BE190033 RPC-2 failed to communicate with the rack ID logic card.
BE190034 RPC-1 and RPC-2, rack ID data CRC check.
BE190035 RPC-2, rack ID data CRC check.
BE190036 RPC-1, rack ID data CRC check.
BE190037 RPC-1, pack data parity error in flash.
BE190038 RPC-2, pack data parity error in flash.
BE190039 Remote force power-off switch is only active on RPC-1.
BE19003A Remote force power-off switch is only active on RPC-2.
BE19003B Interrupt source register failure.
BE19003C RPC-1, PPS-2 interrupt source register failure.
BE19003D RPC-2, PPS-1 interrupt source register failure.
BE19003E RPC-2, PPS-2 interrupt source register failure.
BE19003F RPC-1 indicates that RPC-2 is failing.
BE190040 RPC-2 indicates that RPC-1 is failing.
BE190041 RPC-1 failure caused CEC enclosure 1 communication failure.
BE190042 RPC-1 failure caused CEC enclosure 2 communication failure.
BE190043 RPC-2 failure caused CEC enclosure 1 communication failure.
BE190044 RPC-2 failure caused CEC enclosure 2 communication failure.
BE190045 CEC enclosure 1 standby 3.3V source failure.
BE190046 CEC enclosure 2 standby 3.3V source failure.
BE190047 RPC-1 remote force power-off switch source has failed.
BE190048 RPC-2 remote force power-off switch source has failed.
BE190049 RPC-1, microcode interrupt is active unexpectedly.
BE19004A RPC-2, microcode interrupt is active unexpectedly.
BE19004B Single-SFI loss of master detected with RPC-1 in fenced state.
BE19004C Single-SFI loss of master detected with RPC-2 in fenced state.
BE190050 CEC enclosure 1 failed to communicate with RPC-1 and RPC-2 through serial paths.
BE190051 CEC enclosure 2 failed to communicate with RPC-1 and RPC-2 through serial paths.
BE190052 CEC enclosure 1 and 2 failed to communicate with RPC-1 through serial paths.
BE190053 CEC enclosure 1 and 2 failed to communicate with RPC-2 through serial paths.
BE190054 CEC enclosure 1 failed to communicate with RPC-1 through serial path.
BE190055 CEC enclosure 2 failed to communicate with RPC-1 through serial path.
BE190056 CEC enclosure 1 failed to communicate with RPC-2 through serial path.
BE190057 CEC enclosure 2 failed to communicate with RPC-2 through serial path.
BE190058 CEC enclosure 1 failed to communicate with RPC-1 through serial path.
BE190059 CEC enclosure 2 failed to communicate with RPC-1 through serial path.
BE19005A CEC enclosure 1 failed to communicate with RPC-2 through serial path.
BE19005B CEC enclosure 2 failed to communicate with RPC-2 through serial path.
BE19005C CEC enclosure RS-485 serial interface card diagnostic failure during card power on.
BE19011x RPC-1 and RPC-2 to PPS-1, rack x communication failure.
BE19012x RPC-1 and RPC-2 to PPS-2, rack x communication failure.
BE19013x RPC-1 to PPS-1, rack x communication failure.
BE19014x RPC-1 to PPS-2, rack x communication failure.
BE19015x RPC-2 to PPS-1, rack x communication failure.
BE19016x RPC-2 to PPS-2, rack x communication failure.
BE19017x RPC-1 to PPS-1 and PPS-2, rack x communication failure.
BE19018x RPC-2 to PPS-1 and PPS-2, rack x communication failure.
BE19021x RPC-1 and RPC-2 to PPS-1, rack x communication failure during PPS configuration
BE19022x RPC-1 and RPC-2 to PPS-2, rack x communication failure during PPS configuration
BE19030A RPC-1 local power control mode conflict.
BE19030B RPC-1 remote power control mode conflict.
BE19030C RPC-2 local power control mode conflict.
BE19030D RPC-2 remote power control mode conflict.
BE19100x Rack x, loss of line cord ac.
BE19101x PPS-1 to PPS-2, rack x communication failure.
BE19104x PPS-1 and PPS-2, rack x over current at DDM +5 volt boundary A.
BE19105x PPS-1 and PPS-2, rack x over current at DDM +12 volt boundary A.
BE19106x PPS-1 and PPS-2, rack x over current at DDM +5 volt boundary B.
BE19107x PPS-1 and PPS-2, rack x over current at DDM +12 volt boundary B.
BE19108x PPS-1 and PPS-2, rack x over current at optional DDM +5 volt boundary A.
BE19109x PPS-1 and PPS-2, rack x over current at optional DDM +12 volt boundary A.
BE1910Ax PPS-1 and PPS-2, rack x over current at optional DDM +5 volt boundary B.
BE1910Bx PPS-1 and PPS-2, rack x over current at optional DDM +12 volt boundary B.
BE1910Cx PPS-1 and PPS-2, rack x standby converter off.
BE1910Dx PPS-1 and PPS-2, rack x protected 0 +208 VDC is off.
BE1910Ex PPS-1 and PPS-2, rack x protected 1 +208 VDC is off.
BE1910Fx PPS-1 and PPS-2, rack x rack ID card communication failure.
BE19110x PPS-1, rack x loss of line cord ac.
BE19111x PPS-2, rack x loss of line cord ac.
BE19112x PPS-1, rack x line cord ac is single phase.
BE19113x PPS-2, rack x line cord ac is single phase.
BE19114x PPS-1, rack x input circuit breaker is off.
BE19115x PPS-2, rack x input circuit breaker is off.
BE19116x PPS-1, rack x UEPO switch is active.
BE19117x PPS-2, rack x UEPO switch is active.
BE19118x PPS-1, rack x UEPO converter failure.
BE19119x PPS-2, rack x UEPO converter failure.
BE1911Ax PPS-1, rack x PFC converter failure.
BE1911Bx PPS-2, rack x PFC converter failure.
BE1911Cx PPS-1, rack x internal failure.
BE1911Dx PPS-2, rack x internal failure.
BE1911Ex PPS-1, rack x power-on self-test failed.
BE1911Fx PPS-2, rack x power-on self-test failed.
BE19120x PPS-1, rack x standby converter failure.
BE19121x PPS-2, rack x standby converter failure.
BE19122x PPS-1, rack x sequencer EEPROM failure.
BE19123x PPS-2, rack x sequencer EEPROM failure.
BE19124x PPS-1, rack x sequencer heartbeat failure.
BE19125x PPS-2, rack x sequencer heartbeat failure.
BE19126x PPS-1, rack x age of BBUs differ by more than 2 years.
BE19127x PPS-2, rack x age of BBUs differ by more than 2 years.
BE19128x PPS-1, rack x fan 1 failure.
BE19129x PPS-2, rack x fan 1 failure.
BE1912Ax PPS-1, rack x fan 2 failure.
BE1912Bx PPS-2, rack x fan 2 failure.
BE1912Cx PPS-1, rack x fan 3 failure.
BE1912Dx PPS-2, rack x fan 3 failure.
BE1912Ex PPS-1, rack x over temperature at main 208V.
BE1912Fx PPS-2, rack x over temperature at main 208V.
BE19130x PPS-1, rack x over temperature at PFC.
BE19131x PPS-2, rack x over temperature at PFC.
BE19132x PPS-1, rack x over temperature at main DDM module, bus A.
BE19133x PPS-2, rack x over temperature at main DDM module, bus A.
BE19134x PPS-1, rack x over temperature at main DDM module, bus B.
BE19135x PPS-2, rack x over temperature at main DDM module, bus B.
BE19136x PPS-1, rack x over temperature at optional +208 VDC module.
BE19137x PPS-2, rack x over temperature at optional +208 VDC module.
BE19138x PPS-1, rack x over temperature at booster module.
BE19139x PPS-2, rack x over temperature at booster module.
BE1913Ax PPS-1, rack x over temperature at optional DDM module bus A.
BE1913Bx PPS-2, rack x over temperature at optional DDM module bus A.
BE1913Cx PPS-1, rack x over temperature at optional DDM module bus B.
BE1913Dx PPS-2, rack x over temperature at optional DDM module bus B.
BE1913Ex PPS-1, rack x main +208 VDC over or under voltage.
BE1913Fx PPS-1 (in rack x) module 3 offline and PPS-2 (in rack x) module 3 offline
BE19140x PPS-1 (in rack x) module 4 offline and PPS-2 (in rack x) module 4 offline
BE19141x PPS-2, rack x main +208 VDC over or under voltage.
BE19142x PPS-1, rack x main +5 VDC boundary A over or under voltage.
BE19143x PPS-2, rack x main +5 VDC boundary A over or under voltage.
BE19144x PPS-1, rack x main +12 VDC boundary A over or under voltage.
BE19145x PPS-2, rack x main +12 VDC boundary A over or under voltage.
BE19146x PPS-1, rack x main +5 VDC boundary B over or under voltage.
BE19147x PPS-2, rack x main +5 VDC boundary B over or under voltage.
BE19148x PPS-1, rack x main +12 VDC boundary B over or under voltage.
BE19149x PPS-2, rack x main +12 VDC boundary B over or under voltage.
BE1914Ax PPS-1, rack x optional +5 VDC boundary A over or under voltage
BE1914Bx PPS-2, rack x optional +5 VDC boundary A over or under voltage.
BE1914Cx PPS-1, rack x optional +12 VDC boundary A over or under voltage.
BE1914Dx PPS-2, rack x optional +12 VDC boundary A over or under voltage.
BE1914Ex PPS-1, rack x optional +5 VDC boundary B over or under voltage.
BE1914Fx PPS-2, rack x optional +5 VDC boundary B over or under voltage.
BE19150x PPS-1, rack x optional +12 VDC boundary B over or under voltage.
BE19151x PPS-2, rack x optional +12 VDC boundary B over or under voltage.
BE19152x PPS-1, rack x optional +208 VDC over or under voltage.
BE19153x PPS-2, rack x optional +208 VDC over or under voltage.
BE19154x PPS-1, rack x optional booster module test failed.
BE19155x PPS-2, rack x optional booster module test failed.
BE19156x PPS-1, rack x main DDM +5 VDC A current sharing fault not isolated.
BE19157x PPS-2, rack x main DDM +5 VDC A current sharing fault not isolated.
BE19158x PPS-1, rack x main DDM +5 VDC B current sharing fault not isolated.
BE19159x PPS-2, rack x main DDM +5 VDC B current sharing fault not isolated.
BE1915Ax PPS-1, rack x main DDM +12 VDC A current sharing fault not isolated.
BE1915Bx PPS-2, rack x main DDM +12 VDC A current sharing fault not isolated.
BE1915Cx PPS-1, rack x main DDM +12 VDC B current sharing fault not isolated.
BE1915Dx PPS-2, rack x main DDM +12 VDC B current sharing fault not isolated.
BE1915Ex PPS-1, rack x to front fan sense card communication failure.
BE1915Fx PPS-2, rack x to rear fan sense card communication failure.
BE19160x PPS-1, rack x to front fan sense card data compare failure.
BE19161x PPS-2, rack x to rear fan sense card data compare failure.
BE19162x Rack ID card, rack x Rack_ID CRC failure.
BE19163x Rack ID card, rack x Rack_ID CRC failure.
BE19168x PPS-1, rack x internal I2C interface failure.
BE19169x PPS-2, rack x internal I2C interface failure.
BE1916Ax PPS-1, rack x internal I2C interface failure at PFC.
BE1916Bx PPS-2, rack x internal I2C interface failure at PFC.
BE1916Cx PPS-1, rack x internal I2C interface failure at +208 VDC.
BE1916Dx PPS-2, rack x internal I2C interface failure at +208 VDC.
BE1916Ex PPS-1, rack x internal I2C interface failure at main DDM.
BE1916Fx PPS-2, rack x internal I2C interface failure at main DDM.
BE19170x PPS-1, rack x internal I2C interface failure at booster module.
BE19171x PPS-2, rack x internal I2C interface failure at booster module.
BE19172x PPS-1, rack x internal I2C interface failure at optional module.
BE19173x PPS-2, rack x internal I2C interface failure at optional module.
BE19174x PPS-1, rack x over current at DDM +5 VDC boundary A.
BE19175x PPS-2, rack x over current at DDM +5 VDC boundary A.
BE19176x PPS-1, rack x over current at DDM +12 VDC boundary A.
BE19177x PPS-2, rack x over current at DDM +12 VDC boundary A.
BE19178x PPS-1, rack x over current at DDM +5 VDC boundary B.
BE19179x PPS-2, rack x over current at DDM +5 VDC boundary B.
BE1917Ax PPS-1, rack x over current at DDM +12 VDC boundary B.
BE1917Bx PPS-2, rack x over current at DDM +12 VDC boundary B.
BE1917Cx PPS-1, rack x over current at optional DDM +5 VDC boundary A.
BE1917Dx PPS-2, rack x over current at optional DDM +5 VDC boundary A.
BE1917Ex PPS-1, rack x over current at optional DDM +12 VDC boundary A.
BE1917Fx PPS-2, rack x over current at optional DDM +12 VDC boundary A.
BE19180x PPS-1, rack x over current at optional DDM +5 VDC boundary B.
BE19181x PPS-2, rack x over current at optional DDM +5 VDC boundary B.
BE19182x PPS-1, rack x over current at optional DDM +12 VDC boundary B.
BE19183x PPS-2, rack x over current at optional DDM +12 VDC boundary B.
BE19184x PPS-1, rack x over current at main and optional +208 VDC.
BE19185x PPS-2, rack x over current at main and optional +208 VDC.
BE19186x PPS-1, rack x over current at main +208 VDC with opt. +208 VDC installed.
BE19187x PPS-2, rack x over current at main +208 VDC with opt. +208 VDC installed.
BE19188x PPS-1, rack x over current at optional +208 VDC.
BE19189x PPS-2, rack x over current at optional +208 VDC.
BE1918Ax PPS-1, rack x over current at main +208 VDC.
BE1918Bx PPS-2, rack x over current at main +208 VDC.
BE1918Cx PPS-1, rack x main DDM power boundary A is off.
BE1918Dx PPS-2, rack x main DDM power boundary A is off.
BE1918Ex PPS-1, rack x main DDM +5 VDC power boundary A is off.
BE1918Fx PPS-2, rack x main DDM +5 VDC power boundary A is off.
BE19190x PPS-1, rack x main DDM +12 VDC power boundary A is off.
BE19191x PPS-2, rack x main DDM +12 VDC power boundary A is off.
BE19192x PPS-1, rack x main DDM power boundary B is off.
BE19193x PPS-2, rack x main DDM power boundary B is off.
BE19194x PPS-1, rack x main DDM +5 VDC power boundary B is off.
BE19195x PPS-2, rack x main DDM +5 VDC power boundary B is off.
BE19196x PPS-1, rack x main DDM +12 VDC power boundary B is off.
BE19197x PPS-2, rack x main DDM +12 VDC power boundary B is off.
BE19198x PPS-1, rack x main +208 VDC is off.
BE19199x PPS-2, rack x main +208 VDC is off.
BE1919Ax PPS-1, rack x protected 0 +208 VDC is off.
BE1919Bx PPS-2, rack x protected 0 +208 VDC is off.
BE1919Cx PPS-1, rack x protected 1 +208 VDC is off.
BE1919Dx PPS-2, rack x protected 1 +208 VDC is off.
BE1919Ex PPS-1, rack x optional DDM power boundary A is off.
BE1919Fx PPS-2, rack x optional DDM power boundary A is off.
BE191A0x PPS-1, rack x optional DDM +5 VDC power boundary A is off.
BE191A1x PPS-2, rack x optional DDM +5 VDC power boundary A is off.
BE191A2x PPS-1, rack x optional DDM +12 VDC power boundary A is off.
BE191A3x PPS-2, rack x optional DDM +12 VDC power boundary A is off.
BE191A4x PPS-1, rack x optional DDM power boundary B is off.
BE191A5x PPS-2, rack x optional DDM power boundary B is off.
BE191A6x PPS-1, rack x optional DDM +5 VDC power boundary B is off.
BE191A7x PPS-2, rack x optional DDM +5 VDC power boundary B is off.
BE191A8x PPS-1, rack x optional DDM +12 VDC power boundary B is off.
BE191A9x PPS-2, rack x optional DDM +12 VDC power boundary B is off.
BE191AAx PPS-1, rack x optional +208 VDC is off.
BE191ABx PPS-2, rack x optional +208 VDC is off.
BE191ACx PPS-1, rack x all fans failing.
BE191ADx PPS-2, rack x all fans failing.
BE191AEx PPS-1, rack x fans 1 and 2 failure.
BE191AFx PPS-2, rack x fans 1 and 2 failure.
BE191B0x PPS-1, rack x fans 1 and 3 failure.
BE191B1x PPS-2, rack x fans 1 and 3 failure.
BE191B2x PPS-1, rack x fans 2 and 3 failure.
BE191B3x PPS-2, rack x fans 2 and 3 failure.
BE191B4x PPS-1, rack x rack ID card communication failure.
BE191B5x PPS-2, rack x rack ID card communication failure.
BE191B6x Rack x, front/back mismatch between PPS-1 and RPC-1.
BE191B7x Rack x, front/back mismatch between PPS-2 and RPC-1.
BE191B8x PPS-1, rack x main DDM +5 VDC A current sharing fault.
BE191B9x PPS-2, rack x main DDM +5 VDC A current sharing fault.
BE191BAx PPS-1, rack x main DDM +5 VDC B current sharing fault.
BE191BBx PPS-2, rack x main DDM +5 VDC B current sharing fault.
BE191BCx PPS-1, rack x main DDM +12 VDC A current sharing fault.
BE191BDx PPS-2, rack x main DDM +12 VDC A current sharing fault.
BE191BEx PPS-1, rack x main DDM +12 VDC B current sharing fault.
BE191BFx PPS-2, rack x main DDM +12 VDC B current sharing fault.
BE191C0x PPS-1, rack x optional DDM +5 VDC A current sharing fault.
BE191C1x PPS-2, rack x optional DDM +5 VDC A current sharing fault.
BE191C2x PPS-1, rack x optional DDM +5 VDC B current sharing fault.
BE191C3x PPS-2, rack x optional DDM +5 VDC B current sharing fault.
BE191C4x PPS-1, rack x optional DDM +12 VDC A current sharing fault.
BE191C5x PPS-2, rack x optional DDM +12 VDC A current sharing fault.
BE191C6x PPS-1, rack x optional DDM +12 VDC B current sharing fault.
BE191C7x PPS-2, rack x optional DDM +12 VDC B current sharing fault.
BE191C8x PPS-1, rack x main +208 VDC current sharing fault, opt. +208 installed.
BE191C9x PPS-2, rack x main +208 VDC current sharing fault, opt. +208 installed.
BE191CAx PPS-1, rack x main +208 VDC current sharing fault not isolated.
BE191CBx PPS-2, rack x main +208 VDC current sharing fault not isolated.
BE191CCx PPS-1, rack x optional +208 VDC module current sharing fault.
BE191CDx PPS-2, rack x optional +208 VDC module current sharing fault.
BE191CEx Rack x, front/back mismatch between PPS-1 and RPC-2.
BE191CFx Rack x, front/back mismatch between PPS-2 and RPC-2.
BE191D1x Rack x shows on battery with line cord ac still present.
BE191D2x Rack x shows on battery with line cord ac still present.
BE191D4x RPC-1, True and Not True interrupt state set for PPS-1.
BE191D5x RPC-2, True and Not True interrupt state set for PPS-1.
BE191D6x RPC-1, True and Not True interrupt state set for PPS-2.
BE191D7x RPC-2, True and Not True interrupt state set for PPS-2.
BE191DAx PPS-1, rack x optional booster module is off.
BE191DBx PPS-2, rack x optional booster module is off.
BE191DCx PPS-1 and PPS-2, rack x RPC-1 data, pack data parity error.
BE191DDx PPS-1 and PPS-2, rack x RPC-2 data, pack data parity error.
BE191DEx PPS-1, rack x RPC-1 pack data parity error.
BE191DFx PPS-1, rack x RPC-2 pack data parity error.
BE191E0x PPS-2, rack x RPC-1 pack data parity error.
BE191E1x PPS-2, rack x RPC-2 pack data parity error.
BE191E2x PPS-1, frame x indicating battery low.
BE191E3x PPS-2, frame x indicating battery low.
BE191E4x PPS-1 and PPS-2, rack x indicating battery low.
BE191E5x PPS-1, rack x input circuit breaker is tripped.
BE191E6x PPS-2, rack x input circuit breaker is tripped.
BE191E7x PPS-1, rack x booster module failure during battery test.
BE191E8x PPS-2, rack x booster module failure during battery test.
BE191E9x PPS-1, rack x booster module failure during battery backup.
BE191EAx PPS-2, rack x booster module failure during battery backup.
BE191EBx PPS-1, rack x booster module failure while in hot standby.
BE191ECx PPS-2, rack x booster module failure while in hot standby.
BE191EDx PPS-1, rack x reported control registers are incorrect from RPC-1.
BE191EEx PPS-2, rack x reported control registers are incorrect from RPC-1.
BE191EFx PPS-1, rack x reported control registers are incorrect from RPC-2.
BE191F0x PPS-2, rack x reported control registers are incorrect from RPC-2.
BE191F10 Storage facility was automatically powered on after customer line cord power was restored.
BE191F4x PPS-2, rack x missing battery configuration message.
BE191F5x PPS-1, rack x (x is last digit of reference code) restore of line cord AC.
BE191F6x PPS-2, rack x (x is last digit of reference code) restore of line cord AC.
BE191F7x PPS-1, rack x (x is last digit of reference code) restore of 3-phase line cord AC.
BE191F8x PPS-2, rack x (x is last digit of reference code) restore of 3-phase line cord AC.
BE191F9x PPS-1 and PPS-2, rack x missing system clock setting configuration message.
BE191FAx PPS-1, rack x missing system clock setting configuration message.
BE191FBx PPS-1 and PPS-2, rack x missing battery configuration message.
BE191FCx PPS-1, rack x missing battery configuration message.
BE191FDx PPS-2, rack x missing system clock setting configuration message.
BE191FEx PPS-1, rack x, AC loss conflict - HW AC Off line in PPS-PPS communication cable is open.
BE191FFx PPS-2, rack x, AC loss conflict - HW AC Off line in PPS-PPS communication cable is open.
BE192001 One or more power system batteries are approaching end of life.
BE19201x Rack x, PPS-1 and PPS-2 to BBU1 communication failure.
BE19202x Rack x, PPS-1 and PPS-2 to BBU2 communication failure.
BE19203x Rack x, PPS-1 and PPS-2 to BBU3 communication failure.
BE19204x Rack x, PPS-1 to BBU1, BBU2 and BBU3 comm. failure.
BE19205x Rack x, PPS-2 to BBU1, BBU2 and BBU3 comm. failure.
BE192069 Power system batteries are approaching end of life.
BE19206A Power system batteries are approaching end of life, group 1.
BE19206B Power system batteries are approaching end of life, group 2.
BE19206C Power system batteries are approaching end of life, group 3.
BE19206x Rack x, PPS-1 to BBU1 communication failure.
BE19207x Rack x, PPS-1 to BBU2 communication failure.
BE19208x Rack x, PPS-1 to BBU3 communication failure.
BE19209x Rack x, PPS-2 to BBU1 communication failure.
BE1920Ax Rack x, PPS-2 to BBU2 communication failure.
BE1920Bx Rack x, PPS-2 to BBU3 communication failure.
BE1920Cx Rack x, PPS-1 and PPS-2 to BBU1 charging failure.
BE1920Dx Rack x, PPS-1 and PPS-2 to BBU2 charging failure.
BE1920Ex Rack x, PPS-1 and PPS-2 to BBU3 charging failure.
BE1920Fx Rack x, PPS-1 to BBU1, BBU2 and BBU3 charging failure.
BE19210x Rack x, PPS-2 to BBU1, BBU2 and BBU3 charging failure.
BE19211x Rack x, PPS-1 to BBU1 charging failure.
BE19212x Rack x, PPS-1 to BBU2 charging failure.
BE19213x Rack x, PPS-1 to BBU3 charging failure.
BE19214x Rack x, PPS-2 to BBU1 charging failure.
BE19215x Rack x, PPS-2 to BBU2 charging failure.
BE19216x Rack x, PPS-2 to BBU3 charging failure.
BE19217x Rack x, BBU1 battery voltage not present at output.
BE19218x Rack x, BBU2 battery voltage not present at output.
BE19219x Rack x, BBU3 battery voltage not present at output.
BE1921Ax Rack x, BBU1 fan failure.
BE1921Bx Rack x, BBU2 fan failure.
BE1921Cx Rack x, BBU3 fan failure.
BE1921Dx Rack x, BBU1 temperature sensor failure.
BE1921Ex Rack x, BBU2 temperature sensor failure.
BE1921Fx Rack x, BBU3 temperature sensor failure.
BE19220x Rack x, BBU1 under voltage.
BE19221x Rack x, BBU2 under voltage.
BE19222x Rack x, BBU3 under voltage.
BE19223x Rack x, BBU1 O-ring diode shorted.
BE19224x Rack x, BBU2 O-ring diode shorted.
BE19225x Rack x, BBU3 O-ring diode shorted.
BE19226x Rack x, BBU1 not connected to +208 VDC bus A.
BE19227x Rack x, BBU2 not connected to +208 VDC bus A.
BE19228x Rack x, BBU3 not connected to +208 VDC bus A.
BE19229x Rack x, BBU1 not connected to +208 VDC bus B.
BE1922Ax Rack x, BBU2 not connected to +208 VDC bus B.
BE1922Bx Rack x, BBU3 not connected to +208 VDC bus B.
BE1922Cx Rack x, BBU1 discharge current check.
BE1922Dx Rack x, BBU2 discharge current check.
BE1922Ex Rack x, BBU3 discharge current check.
BE1922Fx Rack x, BBU1 cannot be charged.
BE19230x Rack x, BBU2 cannot be charged.
BE19231x Rack x, BBU3 cannot be charged.
BE19232x Rack x, BBU1 EEPROM failure.
BE19233x Rack x, BBU2 EEPROM failure.
BE19234x Rack x, BBU3 EEPROM failure.
BE19235x Rack x, BBU1 BSM EEPROM failure.
BE19236x Rack x, BBU2 BSM EEPROM failure.
BE19237x Rack x, BBU3 BSM EEPROM failure.
BE19238x Rack x, BBU1 more than 8 months since last charge.
BE19239x Rack x, BBU2 more than 8 months since last charge.
BE1923Ax Rack x, BBU3 more than 8 months since last charge.
BE1923Bx Rack x, BBU1 voltage sensor failure.
BE1923Cx Rack x, BBU2 voltage sensor failure.
BE1923Dx Rack x, BBU3 voltage sensor failure.
BE1923Ex Rack x, PPS-1 and PPS-2 to BBU2 communication failure.
BE1923Fx Rack x, PPS-1 and PPS-2 to BBU3 communication failure.
BE19240x Rack x, PPS-1 to BBU2 and BBU3 communication failure.
BE19241x Rack x, PPS-2 to BBU2 and BBU3 communication failure.
BE19242x Rack x, Multiple BBUs with voltage not present at output.
BE19243x Rack x, PPS-1 voltage sensor failure.
BE19244x Rack x, PPS-2 voltage sensor failure.
BE19245x Rack x, Multiple BBUs under voltage.
BE19248x Rack x, PPS-1 to BBU2 and BBU3 charging failure.
BE19249x Rack x, PPS-2 to BBU2 and BBU3 charging failure.
BE1924Ax Rack x, BBU1 failed connection test and discharge current check.
BE1924Bx Rack x, BBU2 failed connection test and discharge current check.
BE1924Cx Rack x, BBU3 failed connection test and discharge current check.
BE192500 RPC fault not isolated, but RPC in fenced state.
BE19251x Rack x, PPS fault not isolated, but PPS in fenced state.
BE192560 PBCM RPC register corruption with fenced RPC.
BE192561 PBCM RPC register corruption without fenced RPC.
BE192562 PPCL RPC register corruption with fenced RPC.
BE192563 PPCL RPC register corruption without fenced RPC.
BE192564 FDCL RPC register corruption with fenced RPC.
BE192565 FDCL RPC register corruption without fenced RPC.
BE192566 ISR RPC register corruption with fenced RPC
BE192567 ISR RPC register corruption without fenced RPC
BE19252x Rack x, BBU fault not isolated, but BBU in fenced state.
BE193000 HMC Power controlling firmware microcode logic error
BE193001 Start of changeNetwork surveillance has detected a problem over the black or gray network from HMC to both LPARs and FSPs.End of change
BE193002 HMC power controlling firmware MLE. Missing/bad pack ID files on HMC.
BE193003 The RPC/PPS firmware file is missing on the HMC
BE193011 Rack 1, close SRC BE193001: HMC to RPC connection failure.
BE193012 Rack 1, the RPC card flash update/read operation failed.
BE193080 Service Processor function's power controlling firmware microcode logic error
BE1930F0 The number of batteries found does not match what is expected. Check configuration.
BE1930F1 Rack x, expected rack MTMS does not match content in primary PPS-1. Check configuration.
BE193100 Rack 1, RPC-1 not communicating with either service processor function.
BE193101 Rack x, RPC-1 not communicating with either PPS.
BE193102 Rack 1, expected zSeries setting in RPC-1 is not correct.
BE193103 The firmware update to RPC-1 failed.
BE193104 RPC-2 card SF power state is "Off", continuing CDA process for RPC-1 card will cause SF to power off.
BE193105 RPC-2 failed to power on.
BE193106 RPC-1 card SF power control mode failed to change.
BE193110 RPC-1 remote power and RPC-2 local power mode conflict.
BE193111 RPC-1 local power and RPC-2 remote power mode conflict.
BE193150 Rack x, the RPC-1 and RPC-2 communication cables are swapped in PPS.
BE193300 Rack x, both RPCs not communicating with either PPS.
BE193301 Rack x, RPC-1 not communicating with either PPS.
BE193302 Rack 1, expected zSeries setting in RPC-2 is not correct.
BE193303 The firmware update to RPC-2 failed.
BE193306 RPC-2 card SF power control mode failed to change.
BE19350x Rack x, unable to read/write the rack MTMS to primary PPS-1.
BE19351x Rack x, RPC-1 unable to communicate with PPS-1.
BE19352x Rack x, RPC-2 unable to communicate with PPS-1.
BE19353x Rack x PPS-1 unable to communicate with either RPC.
BE19354x Rack x PPS's module count are not equal; the module count in PPS-1 does not match PPS-2.
BE19355x Rack x PPS-1 is unable to obtain battery VPD data.
BE19356x Rack x PPS's contain the PLD module, while the base rack PPS's do not.
BE19357x Rack x PPS's do not contain the PLD module. while the base rack PPS's do.
BE19358x PPS-1, rack x main +208 VDC is off
BE19359x PPS-2, rack x main +208 VDC is off
BE193600 The firmware update to PPS-1 failed.
BE193601 PPS firmware update failed; RPC-1 did not clear PBCM download registers.
BE193602 PPS-1 failed to go into firmware download mode.
BE193603 The firmware S-record data transfer to PPS-1 failed.
BE19370x Rack x, unable to write the rack MTMS to PPS-2.
BE19371x Rack x, RPC-1 unable to communicate with PPS-2.
BE19372x Rack x, RPC-2 unable to communicate with PPS-2.
BE19373x Rack x PPS-2 unable to communicate with either RPC.
BE19374x Rack x - missing, broken, or powered off PLD module in Primary PPS.
BE19375x Rack x - missing, broken, or powered off Optional DDM module in Primary PPS.
BE193800 The firmware update to PPS-2 failed.
BE193802 PPS-2 failed to go into firmware download mode.
BE193803 The firmware S-record data transfer to PPS-2 failed.
BE193804 Loss of input power to multiple CECs and/or I/O enclosures -> possibly bus bar loose cables or failure.
BE193805 Loss of input power to multiple CECs and/or IO Enclosures -> Possibly 'Bus Bar group A' loose cable(s) OR failure.
BE193806 Loss of input power to multiple CECs and/or IO Enclosures -> Possibly 'Bus Bar group B' loose cable(s) OR failure.
BE19381x Rack x (x is last digit of reference code), loss of input power from upper DC-UPS to multiple CECs, I/O enclosures, or both.
BE19382x Rack x (x is last digit of reference code), loss of input power from lower DC-UPS to multiple CECs, I/O enclosures, or both.
BE19383x Rack x (x is last digit of reference code), loss of input power from lower DC-UPS to multiple CECs, I/O enclosures, or both.
BE19384x Rack x (x is last digit of reference code), loss of input power from upper DC-UPS to multiple CECs, I/O enclosures, or both.
BE19385x Rack x (x is last digit of reference code), loss of input power from upper DC-UPS to multiple CECs, I/O enclosures, or both.
BE19386x Rack x (x is last digit of reference code), loss of input power from lower DC-UPS to multiple CECs, I/O enclosures, or both.
BE193900 A power resource failed to Reset Service Mode and is unavailable.
BE19390x Rack x battery or batteries is/are being reported as disconnected.
BE19391x Rack x PPS is reporting missing Line cord ac tripped CB, or no 3 phase power.
BE19392x Rack x MES failure, a PPS or BBU resource in this rack is reporting a fault.
BE19393x Rack x Battery failure, a BBU resource in this rack is reporting a fault.
BE19394x Rack x Battery charging, a BBU resource in this rack is still charging.
BE19395x Rack x PPS-1 may have invalid PPS ID = 1. Communication to RPC is down.
BE19396x Rack x was last powered down using the Red ( UEPO ) Switch.
BE19397x One or more rack x batteries are not present during IML.
BE193A00 Healthcheck detected (internal) fenced component.
BE19400x PPS-1, rack x DDM signal failure at both fan sense cards.
BE19401x PPS-2, rack x DDM signal failure at both fan sense cards.
BE19402x PPS-1, rack x DDM signal failure at front fan sense card.
BE19403x PPS-1, rack x DDM signal failure at rear fan sense card.
BE19404x PPS-2, rack x DDM signal failure at rear fan sense card.
BE19405x PPS-2, rack x DDM signal failure at front fan sense card.
BE19406x PPS-1 and PPS-2, rack x temperature alert.
BE19407x PPS-2, rack x invalid high fan speed setting from PPS-1.
BE19408x PPS-1, rack x invalid high fan speed setting from PPS-2.
BE19409x PPS-2, rack x invalid low fan speed setting from PPS-1.
BE1940Ax PPS-1, rack x invalid low fan speed setting from PPS-2.
BE1940Cx PPS-1, rack x DASD fan tray assembly 2 I2C interface failure.
BE1940Dx PPS-2, rack x DASD fan tray assembly 3 I2C interface failure.
BE1940Ex PPS-1, rack x DASD fan tray assembly 1 I2C interface failure.
BE19410x PPS-1, rack x fan failure in DASD fan tray assembly 2.
BE19411x PPS-2, rack x fan failure in DASD fan tray assembly 3.
BE19412x PPS-1, rack x fan failure in DASD fan tray assembly 1.
BE19414x PPS-1, rack x invalid fan speed setting from rear fan sense card.
BE19415x PPS-2, rack x invalid fan speed setting from front fan sense card.
BE19416x PPS-1, rack x temperature alert.
BE19417x PPS-2, rack x temperature alert.
BE19418x PPS-1, rack x front fan sense card EEPROM failure.
BE19419x PPS-1, rack x rear fan sense card EEPROM failure.
BE19500x PPS-1, rack x main +208 VDC voltage sensor failure.
BE19501x PPS-2, rack x main +208 VDC voltage sensor failure.
BE19502x PPS-1, rack x main +208 VDC current sensor failure.
BE19503x PPS-2, rack x main +208 VDC current sensor failure.
BE19504x PPS-1, rack x optional +208 VDC voltage sensor failure.
BE19505x PPS-2, rack x optional +208 VDC voltage sensor failure.
BE19506x PPS-1, rack x optional +208 VDC voltage current failure.
BE19507x PPS-2, rack x optional +208 VDC voltage current failure.
BE19508x PPS-1, rack x main +5 VDC boundary A voltage sensor failure.
BE19509x PPS-2, rack x main +5 VDC boundary A voltage sensor failure.
BE1950Ax PPS-1, rack x main +5 VDC boundary A current sensor failure.
BE1950Bx PPS-2, rack x main +5 VDC boundary A current sensor failure.
BE1950Cx PPS-1, rack x main +5 VDC boundary B voltage sensor failure.
BE1950Dx PPS-2, rack x main +5 VDC boundary B voltage sensor failure.
BE1950Ex PPS-1, rack x main +5 VDC boundary B current sensor failure.
BE1950Fx PPS-2, rack x main +5 VDC boundary B current sensor failure.
BE19510x PPS-1, rack x optional +5 VDC boundary A voltage sensor failure.
BE19511x PPS-2, rack x optional +5 VDC boundary A voltage sensor failure.
BE19512x PPS-1, rack x optional +5 VDC boundary A current sensor failure.
BE19513x PPS-1, rack x optional +5 VDC boundary A current sensor failure.
BE19514x PPS-1, rack x optional +5 VDC boundary B voltage sensor failure.
BE19515x PPS-2, rack x optional +5 VDC boundary B voltage sensor failure.
BE19516x PPS-1, rack x optional +5 VDC boundary B current sensor failure.
BE19517x PPS-2, rack x optional +5 VDC boundary B current sensor failure.
BE19518x PPS-1, rack x main +12 VDC boundary A voltage sensor failure.
BE19519x PPS-2, rack x main +12 VDC boundary A voltage sensor failure.
BE1951Ax PPS-1, rack x main +12 VDC boundary A current sensor failure.
BE1951Bx PPS-2, rack x main +12 VDC boundary A current sensor failure.
BE1951Cx PPS-1, rack x main +12 VDC boundary B voltage sensor failure.
BE1951Dx PPS-2, rack x main +12 VDC boundary B voltage sensor failure.
BE1951Ex PPS-1, rack x main +12 VDC boundary B current sensor failure.
BE1951Fx PPS-2, rack x main +12 VDC boundary B current sensor failure.
BE19520x PPS-1, rack x optional +12 VDC boundary A voltage sensor failure.
BE19521x PPS-2, rack x optional +12 VDC boundary A voltage sensor failure.
BE19522x PPS-1, rack x optional +12 VDC boundary A current sensor failure.
BE19523x PPS-2, rack x optional DDM +12 VDC boundary A current sensor failure.
BE19524x PPS-1, rack x optional +12 VDC boundary B voltage sensor failure.
BE19525x PPS-2, rack x optional +12 VDC boundary B voltage sensor failure.
BE19526x PPS-1, rack x optional +12 VDC boundary B current sensor failure.
BE19527x PPS-2, rack x optional +12 VDC boundary B current sensor failure.
BE19528x PPS-1, rack x booster module sensor failure.
BE19529x PPS-2, rack x booster module sensor failure.
BE1952Ax Rack ID data cannot be read in rack x; Rack Identify LED is in use.
BE1952Bx Both PPSs detected EPOW or Power Good signal failure on partner in rack x.
BE1952Cx PPS-1 main 208V offline and PPS-2 module 3 offline and PPS-2 module 4 offline in rack x (x is last digit of reference code).
BE1952Dx PPS-2 main 208V offline and PPS-1 module 3 offline and PPS-1 module 4 offline in rack x (x is last digit of reference code).
BE1952Dx PPS-2 main 208V offline and PPS-1 module 3 offline and PPS-1 module 4 offline in rack x (x is last digit of reference code).
BE1952Ex Both PPSs reporting partner EPOW mismatch in rack x (x is last digit of reference code).
BE196010 One CEC enclosure failed to communicate with both RPC cards.
BE196012 One RPC card failed to communicate with multiple CEC enclosures.
BE19700x RPC-1 and RPC-2 are both failing to communicate with DC-UPS in rack x (x is last digit of reference code).
BE19702x RPC is failing to communicate with DC-UPS-1 and DC-UPS-2 in rack x (x is last digit of reference code).
BE19704x RPC-1 is failing to communicate with DC-UPS-1 in rack x (x is last digit of reference code).
BE19705x RPC-2 is failing to communicate with DC-UPS-1 in rack x (x is last digit of reference code).
BE19706x RPC-1 is failing to communicate with DC-UPS-2 in rack x (x is last digit of reference code).
BE19707x RPC-2 is failing to communicate with DC-UPS-2 in rack x (x is last digit of reference code).
BE197080 Rack 2 DC-UPS cable is swapped with Rack 3 DC-UPS cable at RPC-1 card.
BE197081 Rack 2 DC-UPS cable is swapped with Rack 3 DC-UPS cable at RPC-2 card.
BE198C80 RPC to I/O enclosure communications cable misplug reported (RPC-2 detected for RPC-1 intended connection).
BE198C81 RPC-1 to I/O enclosure communications failure reported by one I/O enclosure.
BE198C82 RPC to I/O enclosure communication cable misplug reported (RPC-1 and RPC-2 connections swapped).
BE198C83 RPC to I/O enclosure communication cable misplug reported (RPC-1 detected for RPC-2 intended connection).
BE198C84 RPC-2 to I/O enclosure communication failure reported by one I/O enclosure.
BE198C85 RPC to I/O enclosure communication failure reported by multiple I/O enclosures.
BE198C86 RPC to I/O enclosure communication failures reported by one I/O enclosure involving both RPCs.
BE198C87 I/O enclosure detected unexpected power control message from RPC-1.
BE198C88 I/O enclosure detected unexpected power control message from RPC-2
BE198C89 I/O enclosure I2C interface communication failure with both fans.
BE198C8A I/O enclosure inlet fault with fan 2.
BE198C8B I/O enclosure outlet fault with fan 2.
BE198C8C I/O enclosure unable to detect presence of fan 2.
BE198C8D I/O enclosure input power failure for fan 2.
BE198C8E I/O enclosure inlet fault with fan 1.
BE198C8F I/O enclosure outlet fault with fan 1.
BE198C90 I/O enclosure unable to detect presence of fan 1.
BE198C91 I/O enclosure input power failure for fan 1.
BE198C92 I/O enclosure power supply unit (PSU) 2 is disabled.
BE198C93 I/O enclosure over voltage fault reported on power supply unit (PSU) 2 output voltage.
BE198C94 I/O enclosure under voltage fault reported on power supply unit (PSU) 2 output voltage.
BE198C95 I/O enclosure over current fault reported on power supply unit (PSU) 2 output current.
BE198C96 I/O enclosure power supply unit (PSU) 2 reported loss of AC input voltage.
BE198C97 I/O enclosure over current fault reported on power supply unit (PSU) 2 input current.
BE198C98 I/O enclosure over temperature fault reported on power supply unit (PSU) 2.
BE198C99 I/O enclosure over temperature fault reported on power supply unit (PSU) 2.
BE198C9A I/O enclosure over temperature warning reported on power supply unit (PSU) 2.
BE198C9B I/O enclosure unable to detect presence of power supply unit (PSU) 2.
BE198C9C I/O enclosure direct current failure reported on power supply unit (PSU) 2 output current.
BE198C9D I/O enclosure reported an invalid or unsupported command from power supply unit (PSU) 2.
BE198C9E I/O enclosure reported a command fault from power supply unit (PSU) 2.
BE198C9F I/O enclosure reported a fan fault from power supply unit (PSU) 2.
BE198CA0 I/O enclosure reported a fan warning from power supply unit (PSU) 2.
BE198CA1 I/O enclosure reported an I2C interface communication fault from power supply unit (PSU) 2.
BE198CA2 I/O enclosure reported an I2C interface communication fault from both power supply units.
BE198CA3 I/O enclosure reported a current sharing warning from power supply unit (PSU) 2.
BE198CA4 I/O enclosure reported a 12 volt auxiliary power fault on power supply unit (PSU) 2 output voltage.
BE198CA5 I/O enclosure reported an over current fault on power supply unit (PSU) 2 output current.
BE198CA6 I/O enclosure reported an under voltage fault on power supply unit (PSU) 2 output voltage.
BE198CA7 I/O enclosure reported an over voltage fault on power supply unit (PSU) 2 output voltage.
BE198CA8 I/O enclosure reported a thermal fault on power supply unit (PSU) 2.
BE198CA9 I/O enclosure reported a thermal fault on both power supply units.
BE198CAA I/O enclosure reported a fan fault on power supply unit (PSU) 2.
BE198CAB I/O enclosure power supply unit (PSU) 1 is disabled.
BE198CAC I/O enclosure over voltage fault reported on power supply unit (PSU) 1 output voltage.
BE198CAD I/O enclosure under voltage fault reported on power supply unit (PSU) 1 output voltage.
BE198CAE I/O enclosure over current fault reported on power supply unit (PSU) 1 output current.
BE198CAF I/O enclosure power supply unit (PSU) 1 reported loss of AC input voltage.
BE198CB0 I/O enclosure over current fault reported on power supply unit (PSU) 1 input current.
BE198CB1 I/O enclosure over temperature fault reported on power supply unit (PSU) 1.
BE198CB2 I/O enclosure over temperature warning reported on power supply unit (PSU) 1.
BE198CB3 I/O enclosure unable to detect presence of power supply unit (PSU) 1.
BE198CB4 I/O enclosure direct current failure reported on power supply unit (PSU) 1 output current.
BE198CB5 I/O enclosure reported an invalid or unsupported command from power supply unit (PSU) 1.
BE198CB6 I/O enclosure reported a command fault from power supply unit (PSU) 1.
BE198CB7 I/O enclosure reported a fan fault from power supply unit (PSU) 1.
BE198CB8 I/O enclosure reported a fan warning from power supply unit (PSU) 1.
BE198CB9 I/O enclosure reported an I2C interface communication fault from power supply unit (PSU) 1.
BE198CBA I/O enclosure reported a current sharing warning from power supply unit (PSU) 1.
BE198CBB I/O enclosure reported a 12 volt auxiliary power fault on power supply unit (PSU) 1 output voltage.
BE198CBC I/O enclosure reported an over current fault on power supply unit (PSU) 1 output current.
BE198CBD I/O enclosure reported an under voltage fault on power supply unit (PSU) 1 output voltage.
BE198CBE I/O enclosure reported an over voltage fault on power supply unit (PSU) 1 output voltage.
BE198CBF I/O enclosure reported a thermal fault on power supply unit (PSU) 1.
BE198CC0 I/O enclosure reported a fan fault on power supply unit (PSU) 1.
BE198CC1 I/O enclosure unexpectedly rebooted.
BE198CC2 I/O enclosure has rebooted due to microcode request.
BE198CC3 I/O enclosure has rebooted due to an internal hardware error.
BE198CC4 I/O enclosure has rebooted due to an internal firmware error.
BE198CC5 I/O enclosure has rebooted due to an internal hardware error.
BE198CCD I/O enclosure reported errors on multiple fans.
BE198CCE RPC to I/O enclosure communication failures with one I/O enclosure and reported by multiple RPCs.
BE198CCF RPC to I/O enclosure communication failure.
BE198CD0 RPC to I/O enclosure communication failures reported on multiple I/O enclosures by a single RPC.
BE198CD1 RPC to I/O enclosure communication failures reported on multiple I/O enclosures by multiple RPCs.
BE198CDE I/O enclosure reported an auxiliary power fault.
BE198CDF Unsupported I/O enclosure interrupt detected.
BE198CE0 I/O enclosure fan control and monitoring capability is degraded.
BE198CF0 Microbay has reported a single fan fault.
BE198CF1 Microbay has reported a dual fan fault.
BE198CF6 I2C communication fault reported by microbay.
BE198CF8 Failure to write I/O enclosure interrupt control registers (ICRs) on RPC (C1).
BE198CF9 Failure to write I/O enclosure interrupt control registers (ICRs) on RPC (C2).
Start of changeBE198CFAEnd of change Start of changeRPC internal register contains unexpected value.End of change
BE198D22 Error recovery microcode reporting of power related errors has been manually disabled for an unexpectedly long time.
BE198D41 Management enclosure power supply (E31) power fault to RPC card (C1).
BE198D43 Management enclosure power supply (E31) power fault to RPC card (C2).
BE198D45 Management enclosure power supply (E31) power fault to MC 1, primary management console.
BE198D47 Management enclosure power supply (E31) power fault to MC 2, secondary management console.
BE198D49 Management enclosure power supply (E31) power fault to Ethernet switch (SW1).
BE198D4B Management enclosure power supply (E31) power fault to Ethernet switch (SW2).
BE198D4D Management enclosure power supply (E31) power fault to both fan assembly's inlet impellers.
BE198D4F Management enclosure power supply (E31) power fault to both fan assembly's power impellers.
BE198D51 Management enclosure power supply (E31) internal power fault.
BE198D53 Management enclosure power supply (E31) not detected.
BE198D54 Management enclosure fan assembly (A1) inlet fan fault.
BE198D56 Management enclosure fan assembly (A1) outlet fan fault.
BE198D58 Management enclosure fan assembly (A2) inlet fan fault.
BE198D5A Management enclosure fan assembly (A2) outlet fan fault.
BE198D61 Management enclosure power supply (E31) multidrop cable not detected.
BE198D63 Management enclosure power supply (E32) power fault to RPC card (C1).
BE198D65 Management enclosure power supply (E32) power fault to RPC card (C2).
BE198D67 Management enclosure power supply (E32) power fault to MC 1, primary management console.
BE198D69 Management enclosure power supply (E32) power fault to MC 2, secondary management console.
BE198D6B Management enclosure power supply (E32) power fault to Ethernet switch (SW1).
BE198D6D Management enclosure power supply (E32) power fault to Ethernet switch (SW2).
BE198D6F Management enclosure power supply (E32) power fault to both fan assembly's inlet impellers.
BE198D71 Management enclosure power supply (E32) power fault to both fan assembly's power impellers.
BE198D73 Management enclosure power supply (E32) internal power fault.
BE198D75 Management enclosure power supply (E32) not detected.
BE198D76 Management enclosure fan assembly (A1) inlet fan fault.
BE198D78 Management enclosure fan assembly (A1) outlet fan fault.
BE198D7A Management enclosure fan assembly (A2) inlet fan fault.
BE198D7C Management enclosure fan assembly (A2) outlet fan fault.
BE198D83 Management enclosure power supply (E32) multidrop cable not detected.
BE198D84 UPS not detected.
BE198D85 UPS on battery.
BE198D87 UPS reporting failure.
BE198D89 UPS no longer relying upon battery.
BE198D8C Management enclosure power supply (E31) I2C interface fault to one RPC card.
BE198D8D Management enclosure power supply (E32) I2C interface fault to one RPC card.
BE198D8E Management enclosure power supply (E31) I2C interface fault to both RPC cards.
BE198D8F Management enclosure power supply (E32) I2C interface fault to both RPC cards.
BE198D90 Both management enclosure power supplies report an I2C communication failure with one RPC card.
BE198D91 Both management enclosure power supplies report an I2C communication failure with both RPC cards.
BE198D92 Management enclosure power supply (E31) not operational.
BE198D93 Management enclosure power supply (E32) not operational.
BE198D94 Multiple management enclosure power supplies reporting power fault to RPC card (C1).
BE198D95 Multiple management enclosure power supplies reporting power fault to RPC card (C2).
BE198D96 Multiple management enclosure power supplies reporting power fault to MC 1, primary management console.
BE198D97 Multiple management enclosure power supplies reporting power fault to MC 2, secondary management console.
BE198D98 Multiple management enclosure power supplies reporting power fault to Ethernet switch (SW1).
BE198D99 Multiple management enclosure power supplies reporting power fault to Ethernet switch (SW2).
BE198D9A Multiple management enclosure power supplies reporting power fault to both fan assemblies inlet impellers.
BE198D9B Multiple management enclosure power supplies reporting power fault to both fan assemblies outlet impellers.
BE198D9C AC Input has been restored to this UPS.
BE198DB6 I/O enclosure power control network (PCN) adapter rebooted due to an internal error.
BE19B01x Rack x (x is last digit of reference code), DC-UPS power output not complete: One or more output boundaries are not turned on.
BE19B02x Rack x (x is last digit of reference code), low battery.
BE19B04x Rack x (x is last digit of reference code), DC-UPS on battery.
BE19B06x Rack x (x is last digit of reference code), Control Registers from RPC-2 differ from RPC-1 and indicate off or disabled.
BE19B08x Rack x (x is last digit of reference code), Control Registers from RPC-1 differ from RPC-2 and indicate off or disabled.
BE19B0Bx Rack x (x is last digit of reference code), Both DC-UPSs report a communication failure to RPC.
BE19B0Dx Rack x (x is last digit of reference code), DC-UPS reports communication failures to both RPCs.
BE19B11x Rack x (x is last digit of reference code), DC-UPS has not received the system EPLD configuration message.
BE19B13x Rack x (x is last digit of reference code), DC-UPS local ac input not present.
BE19B15x Rack x (x is last digit of reference code), DC-UPS input circuit breaker is not on.
BE19B16x Rack x (x is last digit of reference code), DC-UPS missing single input ac phase.
BE19B19x Rack x (x is last digit of reference code), DC-UPS UEPO Converter not on.
BE19B1Bx Rack x (x is last digit of reference code), DC-UPS UEPO Contactor not on.
BE19B1Dx Rack x (x is last digit of reference code), DC-UPS partner phase 3 ac is not present.
BE19B1Fx Rack x (x is last digit of reference code), DC-UPS partner phase 2 ac is not present.
BE19B21x Rack x (x is last digit of reference code), DC-UPS partner phase 1 ac is not present.
BE19B25x Rack x (x is last digit of reference code), DC-UPS not supplying output power to phase 3 main output.
BE19B27x Rack x (x is last digit of reference code), DC-UPS not supplying output power to phase 2 main output.
BE19B29x Rack x (x is last digit of reference code), DC-UPS not supplying output power to phase 1 main output.
BE19B2Bx Rack x (x is last digit of reference code), DC-UPS not supplying output power to phase 3 DDM output.
BE19B2Dx Rack x (x is last digit of reference code), DC-UPS not supplying output power to phase 2 DDM output.
BE19B2Fx Rack x (x is last digit of reference code), DC-UPS not supplying output power to phase 1 DDM output.
BE19B37x Rack x (x is last digit of reference code), DC-UPS BSM Set 1 not present.
BE19B38x Rack x (x is last digit of reference code), DC-UPS BSM Set 1 contactor open.
BE19B3Bx Rack x (x is last digit of reference code), DC-UPS BSM Set 1 Battery switch not open.
BE19B3Ex Rack x (x is last digit of reference code), DC-UPS BSM Set 1 disconnected because it has reached battery discharge cutoff.
BE19B41x Rack x (x is last digit of reference code), DC-UPS BSM Set 2 not present.
BE19B42x Rack x (x is last digit of reference code), DC-UPS BSM Set 2 contactor open.
BE19B45x Rack x (x is last digit of reference code), DC-UPS BSM Set 2 Battery switch not open.
BE19B48x Rack x (x is last digit of reference code), DC-UPS BSM Set 2 disconnected because it has reached battery discharge cutoff.
BE19B4Bx Rack x (x is last digit of reference code), DC-UPS BSM Set 3 not present.
BE19B4Cx Rack x (x is last digit of reference code), DC-UPS BSM Set 3 contactor open.
BE19B4Fx Rack x (x is last digit of reference code), DC-UPS BSM Set 3 Battery switch not open.
BE19B51x Rack x (x is last digit of reference code), DC-UPS BSM Set 3 disconnected because it has reached battery discharge cutoff.
BE19B53x Rack x (x is last digit of reference code), DC-UPS input circuit breaker tripped.
BE19B55x Rack x (x is last digit of reference code), DC-UPS DSU fault.
BE19B57x Rack x (x is last digit of reference code), DC-UPS BSM set 1 fault.
BE19B59x Rack x (x is last digit of reference code), DC-UPS BSM set 2 fault.
BE19B5Bx Rack x (x is last digit of reference code), DC-UPS BSM set 3 fault.
BE19B5Dx Rack x (x is last digit of reference code), DC-UPS fan fault.
BE19B60x Rack x (x is last digit of reference code), DC-UPS unsupported interrupt.
BE19B61x Rack x (x is last digit of reference code), DC-UPS BSM set E10 has an invalid serial number in one of the secondary modules.
BE19B62x Rack x (x is last digit of reference code), DC-UPS BSM set E11 has an invalid serial number in one of the secondary modules.
BE19B63x Rack x (x is last digit of reference code), DC-UPS BSM set E12 has an invalid serial number in one of the secondary modules.
BE19B99x Rack x (x is last digit of reference code), DC-UPS DSU to BSM Set 1 (-E10) communications fault.
BE19B9Ax Rack x (x is last digit of reference code), DC-UPS DSU to BSM Set 2 (-E11) communications fault.
BE19B9Bx Rack x (x is last digit of reference code), DC-UPS DSU to BSM Set 3 (-E12) communications fault.
BE19B9Fx Rack x (x is last digit of reference code), DC-UPS BSM set 1 has reached end of life.
BE19BAFx Rack x (x is last digit of reference code), DC-UPS BSM set 1 date of last charge greater than 8 months.
BE19BB1x Rack x (x is last digit of reference code), DC-UPS BSM set 2 has reached end of life.
BE19BC1x Rack x (x is last digit of reference code), DC-UPS BSM set 2 date of last charge greater than 8 months.
BE19BC3x Rack x (x is last digit of reference code), DC-UPS BSM set 3 has reached end of life.
BE19BD3x Rack x (x is last digit of reference code), DC-UPS BSM set 3 date of last charge greater than 8 months.
BE19BD5x Rack x (x is last digit of reference code), DC-UPS communication error with RPC-1.
BE19BD6x Rack x (x is last digit of reference code), DC-UPS communication error with RPC-2.
BE19BD7x Rack x (x is last digit of reference code), DC-UPS communication error with both RPCs.
BE19BD8x Rack x (x is last digit of reference code), RPC communication error to both DC-UPSs.
BE19BD9x Rack x (x is last digit of reference code), Each DC-UPS is reporting a communication error to a different RPC.
BE19BDAx Rack x (x is last digit of reference code), ac input has been restored to this DC-UPS.
BE19BDBx Rack x (x is last digit of reference code), The input circuit breaker has been turned back on this DC-UPS.
BE19BF4x Rack x (x is last digit of reference code), DC-UPS BSM set 1 (-E10) reported born-on date more than 2 years out of sync with a partner BSM set.
BE19BF5x Rack x (x is last digit of reference code), DC-UPS BSM set 2 (-E11) reported born-on date more than 2 years out of sync with a partner BSM set.
BE19BF6x Rack x (x is last digit of reference code), DC-UPS BSM set 3 (-E12) reported born-on date more than 2 years out of sync with a partner BSM set.
BE19BF8x Rack x (x is last digit of reference code), battery failure threshold was exceeded. System might not be able to complete FHD. If a power loss occurs, customer data might be lost.
BE19BF9x Rack x (x is last digit of reference code), DC-UPS BSM set 1 replacement 9 months early warning.
BE19BFAx Rack x (x is last digit of reference code), DC-UPS BSM set 2 replacement 9 months early warning.
BE19BFBx Rack x (x is last digit of reference code), DC-UPS BSM set 3 replacement 9 months early warning.
BE19BFCx Rack x (x is last digit of reference code), DC-UPS BSM set 1 replacement 3 months early warning.
BE19BFDx Rack x (x is last digit of reference code), DC-UPS BSM set 2 replacement 3 months early warning.
BE19BFEx Rack x (x is last digit of reference code), DC-UPS BSM set 3 replacement 3 months early warning.
BE19C00x Rack x (x is last digit of reference code), DC-UPS-1 to DC-UPS-2 phase 1 ac crossover cable is disconnected.
BE19C01x Rack x (x is last digit of reference code), DC-UPS-1 to DC-UPS-2 phase 2 ac crossover cable is disconnected.
BE19C02x Rack x (x is last digit of reference code), DC-UPS-1 to DC-UPS-2 phase 3 ac crossover cable is disconnected.
BE19C04x Rack x (x is last digit of reference code), both DC-UPSs report partner AC input status not good on all phases.
BE19C05x Rack x (x is last digit of reference code), battery test timeout on DC-UPS BSM set 1.
BE19C06x Rack x (x is last digit of reference code), battery test timeout on DC-UPS BSM set 2.
BE19C07x Rack x (x is last digit of reference code), battery test timeout on DC-UPS BSM set 3.
BE19C08x Rack x (x is last digit of reference code), battery test failed to start due to DC-UPS BSM set 1 errors.
BE19C09x Rack x (x is last digit of reference code), battery test failed to start due to DC-UPS BSM set 2 errors.
BE19C0Ax Rack x (x is last digit of reference code), battery test failed to start due to DC-UPS BSM set 3 errors.
BE19C0Bx Rack x (x is last digit of reference code), DC-UPS DSU fault, phase 1 partner switch opened.
BE19C0Dx Rack x (x is last digit of reference code), DC-UPS DSU fault, phase 2 partner switch opened.
BE19C0Fx Rack x (x is last digit of reference code), DC-UPS DSU fault, phase 3 partner switch opened.
BE19C11x Rack x (x is last digit of reference code), DC-UPS BSM set 1 fault, contactor shorted.
BE19C13x Rack x (x is last digit of reference code), DC-UPS BSM set 2 fault, contactor shorted.
BE19C15x Rack x (x is last digit of reference code), DC-UPS BSM set 3 fault, contactor shorted.
BE19C17x Rack x (x is last digit of reference code), battery test stopped due to DC-UPS BSM set 1 fault.
BE19C19x Rack x (x is last digit of reference code), battery test stopped due to DC-UPS BSM set 2 fault.
BE19C1Bx Rack x (x is last digit of reference code), battery test stopped due to DC-UPS BSM set 3 fault.
BE19C20x Rack x (x is last digit of reference code), DC-UPS DSU fault, phase switch shorted.
BE19C21x Rack x (x is last digit of reference code), DC-UPS DSU fault, main output over voltage.
BE19D010 RPC-1 CPLD clock error
BE19D011 RPC-2 CPLD clock error
BE19D120 RPC-1 boot error
BE19D121 RPC-2 boot error
BE19D190 RPC-1 has a microcode logic error
BE19D191 RPC-2 has a microcode logic error.
BE19D1C0 RPC-1 rebooted due to power fault.
BE19D1C1 RPC-2 rebooted due to power fault.
BE19D1D0 RPC-1 rebooted due to unfence by partner RPC.
BE19D1D1 RPC-2 rebooted due to unfence by partner RPC.
BE19D1E0 Checksum failure on RPC-1 configuration data in flash memory.
BE19D1E1 Checksum failure on RPC-2 configuration data in flash memory.
BE19DEAD Loss of ac or a Force Power Off caused Storage Facility to power off.
Table 8. BE1Axxxx system reference codes
System reference code Description
BE1A0000 AIX code update failure.
BE1A0001 SFI code update failure.
Table 9. BE1B System Reference Codes
System Reference Code Description
BE1B0710 CEC enclosure SAS adapter permanent controller failure, IOA not operational, retry limit reached.
BE1B0713 CEC enclosure SAS adapter controller failure, IOA Unit Check with no unit check buffer or IOA Fatal Error Interrupt.
BE1B4150 CEC enclosure SAS adapter PCI bus error detected by controller, hardware error.
BE1B4160 CEC enclosure SAS adapter PCI bus error detected by controller, soft PCI bus error recovered by the IOA.
BE1B8150 CEC enclosure SAS adapter controller failure, hardware error.
BE1B8157 CEC enclosure SAS adapter temporary controller failure. The hardware error requires an adapter reset to recover.
BE1BFF3D CEC enclosure SAS adapter temporary controller failure, soft IOA error recovered by the IOA.
Table 10. BE1C system reference codes
System Reference Code Description
BE1Cxxxx Software PID installation or restore related error.
BE1C8819 Base function software PID expires in 90 days.
BE1C8829 z Synergy software PID expires in 90 days.
BE1C8839 Copy services software PID expires in 90 days.
BE1C8849 CSM on HMC software PID expires in 90 days.
BE1C8813 Base function software PID expires in 30 days.
BE1C8823 z Synergy software PID expires in 30 days.
BE1C8833 Copy services software PID expires in 30 days.
BE1C8843 CSM on HMC software PID expires in 30 days.
BE1C8810 Base function software PID is expired.
BE1C8820 z Synergy software PID is expired.
BE1C8830 Copy services software PID is expired.
BE1C8840 CSM on HMC software PID is expired.
BE1C1010 Base function software PID is installed.
BE1C1020 z Synergy software PID is installed.
BE1C1030 Copy services software PID is installed.
BE1C1040 CSM on HMC software PID is installed.
Table 11. BE1D system reference codes
System reference code Description
BE1D0090 LIC feature build key failed.
BE1D0091 Sequence number in LIC feature key invalid for machine.
BE1D0092 Creation of LIC feature file failed.
BE1D0093 Error decrypting LIC feature string or file.
BE1D0094 Error encrypting LIC feature string or file.
BE1D0095 LIC feature string validation failed.
BE1D0096 Invalid LIC feature type.
BE1D0097 Error opening LIC feature file.
BE1D0098 Error writing to LIC feature file.
BE1D0099 LIC feature file validation failed.
BE1D009A Error activating LIC feature file.
BE1D009B Error displaying LIC feature information.
BE1D009C Error querying LIC feature information.
BE1D009D Error determining product information used for LIC features.
BE1D009E LIC feature storage type is not correct.
BE1D009F Invalid LIC feature key length.
BE1D00A0 Hardcoded LIC feature keys prevent LIC feature keys from being installed.
BE1D00A1 LIC feature cannot be installed due to max LSS for CKD.
BE1D00A2 Invalid capacity value for specified LIC feature type.
BE1D00A3 LIC feature cannot be installed because one of the storage image servers is not currently operational.
BE1D00A4 Remote Mirror and Copy LIC feature is not supported on this model.
BE1D00A5 Metro Mirror LIC feature is not supported on this model.
BE1D00A6 Global Mirror LIC feature is not supported on this model.
BE1D00A7 Configured capacity on Storage Facility Image exceeds the capacity of the storage scope specified in the LIC feature key.
BE1D00A8 LIC feature failure - Mismatch version code of adapters.
BE1D00A9 LIC feature failure - CPSS is not available.
BE1D00AA LIC feature failure - Install license feature detected open OS driver error.
BE1D00A8 LIC feature failure - functional code version does not match between LPARs or between LPARs and host adapters.
BE1D00A9 LIC feature failure - CPSS is not available
BE1D00AA LIC feature failure - Install license feature detected open OS driver error.
BE1D00AB LIC feature failure - invalid parameter.
BE1D00AC LIC feature failure - function is in use.
BE1D00AD LIC feature failure -function is in use.
BE1D00AE The LIC feature is not supported on this model.
Table 12. BE1Exxxx system reference codes
System reference code Description
BE1E1401 Easy Tier application framework error.
BE1E1402 Easy Tier migration ratio or migration rate is below 0.05.
BE1E1403 Easy Tier timeouts on data collection attempts exceeded.
BE1E1404 Easy Tier profile does not exist or is corrupted.
BE1E1405 Customer initiated Easy Tier instructions for directive data placement operations are lost due to persistent data recovery or data saving errors.
BE1E1406 Insufficient free pool space to allow Easy Tier management.
BE1E1E0B IML max retry threshold reached.
BE1E1E0C FHD restore image failure.
BE1E1E0D LMB size incorrectly set.
BE1E1E0E Reserved memory missing from partition profile.
BE1E2000 Log event server failover.
BE1E2010 Service action requested fencing action.
BE1E2016 CPU skew failure.
BE1E2017 Battery charge failure reported by RPCDD.
BE1E201A Local server lost cluster lock race, cannot IML.
BE1E2020 Pinned data.
BE1E2021 Track ID mismatch due to invalid track number.
BE1E2022 Track ID out of range due to invalid track number.
BE1E2023 Pinned data from NV due to missing global data and config methods.
BE1E2026 LSS FC state.
BE1E2027 LSS detected error.
BE1E2028 LSS not ready, data trapped.
BE1E2029 Remote rank inaccessible.
BE1E2030 LSS mismatch detected during IML.
BE1E2033 Rank out of sync.
BE1E2034 LSS out of sync.
BE1E2035 SPOF LSS dual IML standard assign.
BE1E2036 SPOF non-standard assign.
BE1E2040 Failback failure.
BE1E2041 Heartbeat failure.
BE1E2042 Communication failure.
BE1E2043 Mail data failure - cache detected LRC.
BE1E2044 NVS detected LRC.
BE1E2045 Message LRC.
BE1E2046 DMA data error.
BE1E2047 Local timeout.
BE1E2048 Local CSM timeout.
BE1E2049 Single server sync failure.
BE1E2060 Healthcheck found a processor in defined state.
BE1E204A Mail data failure - message processing failure.
BE1E204B NVS phase timeout.
BE1E2050 Config error - NVS preserved area corrupted.
BE1E2051 Config error - NVS preserved area not maintained.
BE1E2052 Config error - NVS size mismatch.
BE1E2053 Config error - NVS server code mismatch.
BE1E2054 Config error - NVS invalid memory size.
BE1E2055 Config error - FHD is larger than NVS memory size.
BE1E2057 Config error - dual IML with unmodified NVS that is too small.
BE1E2058 Config error - global data inaccessible.
BE1E2100 Adapter service error.
BE1E2116 LPAR LIC feature miscompare between partner LPARs of an SFI.
BE1E2118 Install failure.
BE1E2120 Concurrent code load failure.
BE1E2130 Adapter availability disagreement between partitions.
BE1E2151 Local CSM Timeout - Warmstart Beg4Work Timeout.
BE1E2152 Local CSM Timeout - CPU Heartbeat Pulsetaker.
BE1E2153 Local CSM Timeout - Crash Call for a Panic Failover.
BE1E2154 Local CSM Timeout - Abort Scanloops Timeout.
BE1E2155 Local CSM Timeout - Incorrect Jump Buffer, Crash.
BE1E2156 Local CSM Timeout - Master Can Not Kill Scanloops.
BE1E2157 Local CSM Timeout - Statesave Lock Held.
BE1E2158 Local CSM Timeout - Longjump From Statesave Code.
BE1E2159 Adapter service error - adapter not found in the device tree.
BE1E215C OS CSM timeout, out of user memory.
BE1E215D NVS received bad mail LRC.
BE1E215E NVS unable to set FC-08 in IMLBack, data loss has occurred.
BE1E215F Modified data - unable to IML dual cluster.
BE1E2162 An AIX crash has occurred because microcode has detected a CSM timeout.
BE1E2163 An unrecoverable CSM timeout condition has occurred.
BE1E2169 Low cache memory condition detected by LPAR cache during IML.
BE1E216A NVS running out of memory.
BE1E2170 A task control block manager detected a deadlock and consequently re-initialized the system.
BE1E2171 The storage facility image was warmstarted because a Global Mirror session did not complete.
BE1E2172 IO Priority Manager failed in the analysis process (SLA) and has been stopped.
BE1E2173 IO Priority Manager failed in the kernel process (SRI) and has been stopped.
BE1E2174 Storage facility image exceeded threshold for recursive warmstarts.
BE1E2179 Easy Tier statistics buffer capacity exceeded. Additional customer storage will not be monitored.
BE1E2182 Partner LPAR could not be resumed because LIC level of the operating LPAR is higher.
BE1E2188 The number of quickstart attempts on the adapter exceeded the threshold.
BE1E2189 During quickstart, the statesave lock acquire process has timed out.
BE1E218C Service action requested delay fence action.
BE1E218D Fixed block microcode has timed out waiting for a SCSI task to complete.
BE1E218E Resource causing repeated warmstarts
BE1E2193 Unexpected condition encountered during service action.
BE1E2500 Slot level fabric error has been detected.
BE1E2501 EADS global level fabric error has been detected.
BE1E2502 PHB level fabric error has been detected.
BE1E2503 Bridge level fabric error has been detected.
BE1E2504 Hub level fabric error has been detected.
BE1E2508 RIO SAN connection has gone offline.
BE1E250A A Read/Write with check failed due to an EEH event.
BE1E250B PHYP forced slot into freeze during upstream fabric error recovery.
BE1E250C No path through the fabric exists to this IOA.
BE1E250D EEH event on this IOA slot has been detected.
BE1E250E EEH event caused by IOA asserting SERR.
BE1E250F EEH event caused by host MMIO RAM error.
BE1E2510 EEH event caused by EADSX detecting bad parity on PHB.
BE1E2511 EEH event caused by EADSX detecting bad parity on IOA bus.
BE1E2512 EEH event caused by EADSX master aborted by PHB.
BE1E2513 EEH event caused by EADSX master aborted by IOA.
BE1E2514 EEH event caused by EADSX target aborted by PHB.
BE1E2515 EEH event caused by EADSX target aborted by IOA.
BE1E2516 EEH event caused by EADSX destination bus was reset.
BE1E2517 EEH event caused by EADSX detecting bad write data parity on PHB bus.
BE1E2518 EEH event caused by EADSX detecting bad write data parity on IOA bus.
BE1E2519 EEH event caused by EADSX discarding delayed completion operation because IOA did not retry the operation in time.
BE1E251A EEH event caused by EADSX discarding delayed completion operation because PHB did not retry the operation in time.
BE1E251B EEH event caused by EADSX master bus timeout on IOA bus.
BE1E251C EEH event caused by EADSX timeout waiting for PHB to return split.
BE1E251D EEH event caused by EADSX timeout waiting for IOA to return split.
BE1E251E EEH event caused by EADSX received split completion message from PHB.
BE1E251F EEH event caused by EADSX received split completion message from IOA.
BE1E2520 EEH event caused by EADSX received master/target abort from PHB when it tried to return a split completion.
BE1E2521 EEH event caused by EADSX received master/target abort from IOA or IOA bus was reset when EADSX tried to return a split completion.
BE1E2522 EEH event caused by EADSX entering freeze state for an unknown reason.
BE1E2523 Fire hose dump performed because of an EPOW3 event.
BE1E2524 ASQ Status of H_Hardware Event; search for other SRCs (1xxx00AD) for specific information about the error.
BE1E253B An invalid enhanced error handling (EEH) reset state has been detected
BE1E2540 A timeout occurred trying to connect across one of the SMCA connections. At least one other SMCA was able to successfully connect.
BE1E2541 This server needs to reboot because it has reserved, uninitialized PHBs in its device tree.
BE1E2542 This server will switch to single IML because the remote server has reserved, unitialized PHBs in its device tree.
BE1E2543 This server has reserved tower slots in its device tree.
BE1E2544 Adapter discovery failure caused by not being able to enable EEH mode.
BE1E2545 Adapter discovery failure caused by slot entering an EEH reset state.
BE1E2546 Adapter discovery failure caused by failure to perform a query of the IOA slot.
BE1E2547 Adapter discovery failure caused by not being able to create an ADS for the IOA.
BE1E2548 Adapter discovery failure caused by not being able to get a bus handle for the IOA.
BE1E2549 Adapter discovery failure caused by not being able to create a logical name for the IOA.
BE1E254A Adapter discovery failure caused by not being able to setup the BARs for the IOA.
BE1E254B Adapter discovery failure caused by not being able to enable the I/O event for the IOA.
BE1E254C An attempt to take over a tower failed.
BE1E254F The power cycle threshold for a tower has been reached.
BE1E2551 A CEC has failed in such a way that it requires a power cycle, but microcode is unable to do it automatically, so it requires a service action.
BE1E2552 After a power cycle of a CEC, a timeout occurred waiting for PHYP to reestablish cross-CEC communication.
BE1E2553 Unable to obtain preserved memory information because firmware RTAS call encountered a hardware error.
BE1E2554 RIO topology failure.
BE1E2555 Number of SMCAs in the device tree not valid for machine model type.
BE1E2559 The local server is missing one or more towers.
BE1E255A An adapter discovery failed because an incorrect adapter card was plugged into the slot.
BE1E255B Generic adapter discovery error.
BE1E255E IOA Slot Power Failure Detected.
BE1E255F Adapter missing from tower slot.
BE1E257D Page Fault Detected by microcode.
BE1E25AA A single CEC to I/O enclosure PCIe link fault was detected during a CEC IML.
BE1E25AB Multiple CEC to I/O enclosure PCIe link faults were detected during a CEC IML.
BE1E2F00 IBM Database Protection Error (Log).
BE1E2F01 IBM Database Protection Error (Reject).
BE1E3002 Panic MLE.
BE1E3003 Panic failover.
BE1E3006 One shot panic.
BE1E3009 One shot panic ODD.
BE1E300F Panic MLE threshold with server fence.
BE1E8546 DMA timeout error on all four paths of the RPCs to CECs serial interface
BE1E8547 Bad LRC detected on different adapters on the RPCs to CECs serial interface
BE1E854A RPCs to CECs serial interface not present
BE1E854D RPC head error
BE1E8554 ODM data corrupted: rsRack object, invalid value for the number of BSM sets installed
BE1EFC06 Cache has set FC-06 state (loss of access to data).
BE1EFC08 Cache has set FC-08 state (loss of access to data).
BE1EFC0A A volume that is host addressable has become fenced (FC-08 state, subtype 04).
BE1EFC0B A volume that is not host addressable (safeguarded backup capacity) has become fenced (FC-08 state, subtype 05).
BE1EFCFF Volume in flash copy has set FC-08 Subtype 04 state.