Event ID Notification type Condition Error code
009020 E An automatic system recovery has started. All configuration commands are blocked. 1001
009040 E The error event log is full. 1002
009052 W The following causes are possible:
  • The node is missing.
  • The node is no longer a functional member of the system.
1196
009053 E A node has been missing for 30 minutes. 1195
009100 W The software install process has failed. 2010
009101 W The software update package delivery has failed. 2010
009150 W Unable to connect to the SMTP (email) server 2600
009151 W Unable to send mail through the SMTP (email) server 2601
009170 W The Metro Mirror or Global Mirror feature capacity is not set. 3030
009171 W The FlashCopy® feature capacity is not set. 3031
009172 W The Virtualization feature has exceeded the amount that is licensed. 3032
009173 W The FlashCopy feature has exceeded the amount that is licensed. 3032
009174 W The Metro Mirror or Global Mirror feature has exceeded the amount that is licensed. 3032
009175 W The usage for the thin-provisioned volume is not licensed. 3033
009176 W The value set for the virtualization feature capacity is not valid. 3029
009177 E A physical disk FlashCopy feature license is required. 3035
009178 E A physical disk Metro Mirror and Global Mirror feature license is required. 3036
009179 E A virtualization feature license is required. 3025
009180 E Automatic recovery of offline node failed. 1194
009181 W Unable to send email to any of the configured email servers. 3081
009182 W The external virtualization feature license limit was exceeded. 3032
009183 W Unable to connect to LDAP server. 2251
009184 W The LDAP configuration is not valid. 2250
009185 E The limit for the compression feature license was exceeded. 3032
009186 E The limit for the compression feature license was exceeded. 3032
009187 E Unable to connect to LDAP server that has been automatically configured. 2256
009188 E Invalid LDAP configuration for automatically configured server. 2255
009189 W A licensable feature's trial-timer has reached 0. The feature has now been deactivated. 3082
009190 W A trial of a licensable feature will expire in 5 days. 3083
009191 W A trial of a licensable feature will expire in 10 days. 3084
009192 W A trial of a licensable feature will expire in 15 days. 3085
009193 W A trial of a licensable feature will expire in 45 days. 3086
009194 W Easy Tier feature license limit exceeded. 3032
009195 W FlashCopy feature license limit exceeded. 3032
009196 W External virtualization feature license limit exceeded. 3032
009197 W Remote copy feature license limit exceeded. 3032
010002 E The node ran out of base event sources. As a result, the node has stopped and exited the system. 2030
010003 W The number of device logins has reduced. 1630
010006 E A software error has occurred. 2030
010008 E The block size is invalid, the capacity or LUN identity has changed during the managed disk initialization. 1660
010010 E The managed disk is excluded because of excessive errors. 1310
010011 E The remote port is excluded for a managed disk and node. 1220
010012 E The local port is excluded. 1210
010013 E The login is excluded. 1230
010017 E A timeout has occurred as a result of excessive processing time. 1340
010018 E An error recovery procedure has occurred. 1370
010019 E A managed disk I/O error has occurred. 1310
010020 E The managed disk error count threshold has exceeded. 1310
010021 W There are too many devices presented to the clustered system. 1200
010022 W There are too many managed disks presented to the cluster (system). 1200
010023 W There are too many LUNs presented to a node. 1200
010024 W There are too many drives presented to a cluster (system). 1200
010025 W A disk I/O medium error has occurred. 1320
010026 W A suitable MDisk or drive for use as a quorum disk was not found. 1330
010027 W The quorum disk is not available. 1335
010028 W A controller configuration is not supported. 1625
010029 E A login transport fault has occurred. 1360
010030 E A managed disk error recovery procedure (ERP) has occurred. The node or controller reported the following:
  • Sense
  • Key
  • Code
  • Qualifier
1370
010031 E One or more MDisks on a controller are degraded. 1623
010032 W The controller configuration limits failover. 1625
010033 E The controller configuration uses the RDAC mode; this is not supported. 1624
010034 E Persistent unsupported controller configuration. 1695
010040 E The controller system device is only connected to the node through a single initiator port. 1627
010041 E The controller system device is only connected to the node through a single target port. 1627
010042 E The controller system device is only connected to the clustered system nodes through a single target port. 1627
010043 W The controller system device is only connected to the clustered system nodes through half of the expected target ports. 1627
010044 E The controller system device has disconnected all target ports to the clustered system nodes. 1627
010055 W An unrecognized SAS device. 1665
010056 E SAS error counts exceeded the warning thresholds. 1216
010057 E SAS errors exceeded critical thresholds. 1216
010066 W Controller indicates that it does not support descriptor sense for LUNs that are greater than 2 TBs. 1625
010067 W Too many enclosures were presented to a cluster (system). 1200
010070 W Too many controller target ports were presented to the cluster (system). 1200
010071 W Too many target ports were presented to the clustered system from a single controller. 1200
010098 W There are too many drives presented to a cluster (system). 1200
010100 W Reserved SAS port has devices attached. 1669
010101 E Too many long IOs to drive. 1215
010102 E A drive is reported as continuos slow with contributory factors. 1215
010103 E Too many long IOs to drive (Mercury drives). 1215
010104 E A drive is reported as continuos slow with contributory factors (Mercury drives). 1215
010106 W Drive reporting too many recovered logical block check errors 1680
010110 W Drive firmware download cancelled because of system changes 3090
010111 W Drive firmware download cancelled because of a drive download problem 3090
010118 W Too many drives attached to the system. 1179
010119 W Drive protection information mismatch 1322
010120 W A member drive has been forced to turn off protection information support. 2035
020001 E There are too many medium errors on the managed disk. 1610
020002 E A storage pool is offline. 1620
020003 W There are insufficient virtual extents. 2030
029001 W The managed disk has bad blocks. On an external controller, this can only be a copied medium error. 1840
029002 E The system failed to create a bad block because MDisk already has the maximum number of allowed bad blocks. 1226
029003 E The system failed to create a bad block because the clustered system already has the maximum number of allowed bad blocks. 1225
030000 W The trigger prepare command has failed because of a cache flush failure. 1900
030010 W The mapping is stopped because of the error that is indicated in the data. 1910
030020 W The mapping is stopped because of a clustered system or complete I/O group failure, and the current state of the relationship could not be recovered. 1895
045101 E Enclosure slot speed below maximum capability. 1686
050001 W The relationship is stopped because of a clustered system or complete I/O group failure, and the current state of the mapping could not be recovered. 1700
050002 W A Metro Mirror or Global Mirror relationship or consistency group exists within a clustered system, but its partnership has been deleted. 3080
050010 W A Global Mirror relationship has stopped because of a persistent I/O error. 1920
050011 W A remote copy has stopped because of a persistent I/O error. 1915
050020 W Remote copy has stopped. 1720
050030 W There are too many clustered system partnerships. The number of partnerships has been reduced. 1710
050031 W There are too many clustered system partnerships. The system has been excluded. 1710
050040 W Background copy process for the Remote Copy was blocked. 1960
050050 W The Global Mirror secondary volume is offline. The relationship has pinned hardened write data for this volume. 1925
050060 W The Global Mirror secondary volume is offline due to missing IO group partner node. The relationship has pinned hardened write data for this volume but the node containing the required data is currently offline. 1730
050070 W Global Mirror performance is likely to be impacted. A large amount of pinned data for the offline volumes has reduced the resource available to the global mirror secondary disks. 1925
060001 W The thin-provisioned volume copy is offline because there is insufficient space. 1865
060002 W The thin-provisioned volume copy is offline because the metadata is corrupt. 1862
060003 W The thin-provisioned volume copy is offline because the repair has failed. 1860
060004 W The compressed volume copy is offline because there is insufficient space. 1865
060005 W The compressed volume copy is offline because the metadata is corrupt. 1862
060006 W The compressed volume copy is offline because the repair has failed. 1860
060007 W The compressed volume copy has bad blocks. 1850
062001 W Unable to mirror medium error during volume copy synchronization 1950
062002 W The mirrored volume is offline because the data cannot be synchronized. 1870
062003 W The repair process for the mirrored disk has stopped because there is a difference between the copies. 1600
070000 E Unrecognized node error. 1083
070510 E Detected memory size does not match the expected memory size. 1022
070511 E DIMMs are incorrectly installed. 1009
070517 E The WWNN that is stored on the service controller and the WWNN that is stored on the drive do not match. 1192
070521 E Unable to detect any Fibre Channel adapter. 1016
070522 E The system board processor has failed. 1020
070523 W The internal disk file system of the node is damaged. 1187
070524 E Unable to update BIOS settings. 1027
070525 E Unable to update the service processor firmware for the system board. 1020
070528 W The ambient temperature is too high while the system is starting. 1182
070536 W A system board device breached critical temperature threshold. 1084
070538 W A PCI Riser breached critical temperature threshold. 1085
070542 E A processor has failed. 1024
070543 E No usable persistent data could be found on the boot drives. 1035
070544 E The boot drives do not belong in this node. 1035
070545 E Boot drive and system board mismatch. 1035
070550 E Cannot form clustered system due to lack of resources. 1192
070556 E Duplicate WWNN detected on the SAN. 1192
070558 E A node is unable to communicate with other nodes. 1192
070562 E The node hardware does not meet minimum requirements. 1183
070564 E Too many software failures. 1188
070574 E The node software is damaged. 1187
070576 E The clustered system data cannot be read. 1030
070578 E The clustered system data was not saved when power was lost. 1194
070580 E Unable to read the service controller ID. 1044
070690 W Node held in service state. 1189
073003 E The Fibre Channel ports are not operational. 1060
073005 E Clustered system path failure. 1550
073006 W The SAN is not correctly zoned. As a result, more than 512 ports on the SAN have logged into one FlashSystem™ V840 port. 1800
073305 W One or more Fibre Channel ports are running at a speed that is lower than the last saved speed. 1065
073310 E A duplicate Fibre Channel frame has been detected, which indicates that there is an issue with the Fibre Channel fabric. Other Fibre Channel errors might also be generated. 1203
073512 E Enclosure VPD is inconsistent 1008
073522 E The system board service processor has failed. 1034
073528 E Ambient temperature is too high during system startup. 1098
074001 W Unable to determine the vital product data (VPD) for an FRU. This is probably because a new FRU has been installed and the software does not recognize that FRU. The clustered system continues to operate; however, you must update the software to fix this warning. 2040
074002 E The node warm started after a software error. 2030
074003 W A connection to a configured remote system has been lost because of a connectivity problem. 1715
074004 W A connection to a configured remote system has been lost because of too many minor errors. 1716
076001 E The internal disk for a node has failed. 1030
076002 E The hard disk is full and cannot capture any more output. 2030
076401 E One of the two power supply units in the node has failed. 1096
076402 E One of the two power supply units in the node cannot be detected. 1096
076403 E One of the two power supply units in the node is without power. 1097
076502 E Degraded PCIe lanes on a high-speed SAS adapter. 1121
076503 E A PCI bus error occurred on a high-speed SAS adapter. 1121
076504 E A high-speed SAS adapter requires a PCI bus reset. 1122
076505 E Vital product data (VPD) is corrupt on high-speed SAS adapter. 1121
079500 W The limit on the number of clustered system secure shell (SSH) sessions has been reached. 2500
079501 W Unable to access the Network Time Protocol (NTP) network time server. 2700
082001 E A server error has occurred. 2100
084000 W An array MDisk has deconfigured members and has lost redundancy. 1689
084100 W An array MDisk is corrupt because of lost metadata. 1240
084200 W Array MDisk has taken a spare member that does not match array goals 1692
084201 W An array has members that are located in a different I/O group. 1688
084300 W An array MDisk is no longer protected by an appropriate number of suitable spares. 1690
084301 W No spare protection exists for one or more array MDisks. 1690
084500 W An array MDisk is offline. The metadata for the inflight writes is on a missing node. 1243
084600 W An array MDisk is offline. Metadata on the missing node contains needed state information. 1243
084700 W An array has lost redundancy due to slow write by member drive. 1750
085001 E Power supply failed. 1124
085002 E The power supply has no input power. 1138
085003 E Power supply communication error. 1126
085004 E Power supply has invalid VPD. 1125
085005 E Power supply is missing. 1128
085006 E Power supply fan failed. 1124
085007 W Power supply units are mismatched.  
085010 E Fan is operating outside expected range. 1067
085011 E Fan communication error. 1068
085004 E Power supply has invalid VPD. 1125
085012 E Fan failed. 1067
085013 E Fan is missing. 1068
085014 E Fan has invalid VPD. 1067
085021 E Flash module failed. 1680
085022 E Flash module communication error. 1680
085023 E Flash module health is low. 1680
085024 E Array mdisk is corrupt. 1240
085025 W The array is degraded. 1689
085026 E Flash module has invalid VPD. 1680
085027 E Flash module is missing. 1684
085028 E Flash module is unsupported. 1240
085029 E Data consistency check failed. 3081
085030 W Extra flash module found that is not part of array. 2070
085031 W Array is missing a spare flash module. 1690
085033 W Flash module not initialized. 1741
085041 E Battery failed. 1114
085042 W Battery missing. 1112
085043 E Battery communication error. 1112
085044 E Battery is nearing end of life. 1115
085045 E Battery is at end of life. 1114
085046 E Battery VPD is not valid. 1114
085048 W Battery maintenance discharge cycle required. 1131
085049 E Battery failed to calibrate during maintenance discharge cycle.  
085051 E Interface card communication error. 1039
085053 E Interface card failed. 1039
085057 E External FC port not operational. 1061
085058 E External IB port not operational. 1350
085059 E FC interface card data communication offline. 1039
085060 E IB interface card data communication offline. 1039
085061 W Too many FC host logins. 1802
085062 W Too many IB host logins. 1804
085064 E Interface card is not supported. 1471
085065 W External FCoE data link degraded. 1064
085066 E External FCoE port not operational. 1061
085067 E FCoE card data communication offline. 1039
085068 W Too many FCoE host logins. 1802
085071 E Canister failed. 1039
085072 E Canister to canister communication error. 1007
085073 E The canister is missing. 1039
085076 E Canister internal error. 1034
085090 E A quorum device is not detected. 1114
085099 E The front panel is not detected. 1338
085110 E Flash module update failed. 1680
085111 E Battery module update failed. 1114
085112 E Canister update failed. 1039
085113 W System update requires a reboot to complete.  
085119 E System update failed. 1048
085135 W Flash module shutdown temperature threshold exceeded. 1087
085136 W Flash module warning temperature threshold exceeded. 1099
085137 W Power supply shutdown temperature threshold exceeded. 1087
085138 W Power supply warning temperature threshold exceeded. 1099
085139 W Battery shutdown temperature threshold exceeded. 1087
085140 W Battery warning temperature threshold exceeded. 1099
085141 E Battery temperature fault. 1114
085142 E Flash module temperature fault. 1680
085151 W Encryption key not available. 1740
085152 W Encryption key not valid. 1740
085153 E T3 recovery device has been slandered. 1114
085154 E Quorum device is missing. 1114
085155 W Encryption key changes are not committed.  
085156 W Array parity compromised.  
085157 E Unexpected encryption error.  
085158 E Flash module encryption error