Verifying the health of EE connection
VTAM® sends a Logical Data Link Control (LDLC) probe to the remote partner to determine whether all ports are accessible during the activation of the EE connection by default. EE health verification for this connection activation fails if VTAM does not receive a response, or receives an error response, from the remote partner.
VTAM also verifies the health of EE connections at other user-specified time intervals. To do this, VTAM sends an LDLC probe to the remote partner on a user-specified interval. If the LDLC probe does not reach any port, VTAM issues the eventual action error message if it is not already present. The eventual action error message stays on console until the customer clears the message or all active EE connections receive successful EE health verification during the most recent LDLC probe.
The D NET,EE,LIST=EEVERIFY command displays all lines that failed EE health verification during the most recent LDLC probe.
The D NET,EE,ID=puname or linename command displays EE health verification information of the most recent LDLC probe for a particular connection.
VTAM provides the EE health verification information of the most recent LDLC probe to the NMI application upon its request. It includes success and failure information for all ports and contains the round-trip time information.
IST2330I EE HEALTH VERIFICATION FAILED FOR puname AT timeIST2342I EE HEALTH VERIFICATION NOT SUPPORTED BY punameIST2323E EE HEALTH VERIFICATION FAILED FOR ONE OR MORE CONNECTIONSIST2325I LINE linename PU puname ON date AT time