SCWA mapping

Table 1. Structure SCWA
Offset
Dec
Offset
Hex
Type Len Name(Dim) Description
0 (0) STRUCTURE 4064 SCWA SUPERVISOR CONTROL WORK AREA
0 (0) CHARACTER 4  SCWASCWA SCWA ACRONYM
4 (4) BITSTRING 4  SCWFLAG  
4 (4) BITSTRING 1   SCWFLAG1 FLAGS. SERIALIZED BY DISABLEMENT.
      1... ....    SCWSARP IF THIS FLAG IS ON AT ENTRY TO IEAVESAR, IEAVESAR HAS BEEN RECURSIVELY ENTERED.
      .1.. ....    SCWELKRF IF THIS FLAG IS ON, THEN IEAVELKR WAS PROCESSING DUE TO BEING CALLED DIRECTLY BY RTM. IEAVESAR USES THIS FLAG TO PREVENT RECURSIVE ENTRY INTO IEAVELKR.
      ..1. ....    SCWLCRVT IF THIS FLAG IS ON, THEN IEAVELCR WAS UNABLE TO REFRESH THE PSAATCVT POINTER TO VTAM'S CVT. IEAVELCR USES THIS FLAG TO PREVENT FILLING LOGREC WITH REDUNDANT SOFTWARE ERROR RECORDS.
      ...1 ....    SCWEGR IF THIS FLAG IS ON, THEN IEAVEGR PROCESSING IS ACTIVE. IEAVESAR USES THIS FLAG TO PREVENT RECURSIVE ENTRY INTO IEAVEGR.
      .... 1111    * RESERVED.
5 (5) BITSTRING 3   * RESERVED.
8 (8) CHARACTER 72  SCWEPC1 PROGRAM FLIH SAVE AREA
80 (50) CHARACTER 72  SCWELK1 SPIN LOCK MGR SAVE AREA
152 (98) CHARACTER 72  SCWELK2 SPIN LOCK MGR SAVE AREA
224 (E0) CHARACTER 64  SCWELK3 SPIN LOCK MGR SAVE AREA
288 (120) CHARACTER 72  SCWEPC3 PROGRAM FLIH SAVE AREA
360 (168) CHARACTER 8  * Reserved
368 (170) CHARACTER 64  SCWFRLK1 FREE LOCK REGISTERS
432 (1B0) CHARACTER 72  SCWESAR SUPERVISOR ANALYSIS ROUTER SAVE AREA.
504 (1F8) CHARACTER 72  SCWESAR2 SECOND LEVEL SAVE AREA TO BE PASSED FROM THE ROUTINES CALLED BY IEAVESAR TO THE ROUTINES THEY CALL.
576 (240) CHARACTER 16  SCWUSRR WORK AREA FOR USERRDY.
592 (250) CHARACTER 40  SCWVQVPL QVPL USED BY IEAVEVRR.
632 (278) CHARACTER 72  SCWEPC2 PROGRAM FLIH SAVE AREA
704 (2C0) CHARACTER 128  SCWSIGP IPC/IEAVESGP SAVE AREA
832 (340) CHARACTER 96  SCWEDR IPC/IEAVEDR SAVE AREA
928 (3A0) CHARACTER 64  SCWELK4 WORK AREA FOR LOCK MANAGER (IEAVELK) - INCLUDES AREA FOR EXCESSIVE SPIN ROUTINE PARAMETER LIST
992 (3E0) CHARACTER 56  SCWEINT WORK AREA FOR INTERSECT SPIN ROUTINE (IEAVEINT) - INCLUDES AREA FOR EXCESSIVE SPIN ROUTINE PARAMETER LIST
1048 (418) CHARACTER 160  * Reserved
1208 (4B8) CHARACTER 104  SCWERP IPC/IEAVERP1 SAVE AREA
1312 (520) CHARACTER 112  SCWEXS IPC/IEAVEXS SAVE AREA
1424 (590) CHARACTER 64  SCWSARWA TEMPORARY WORKAREA FOR IEAVESAR AND THE ROUTINES WHICH RUN UNDER ITS CONTROL.
1488 (5D0) CHARACTER 8  SCWR5D8 Reserved
1496 (5D8) ADDRESS 4  SCWA1PTR POINTER TO SCWA1
1500 (5DC) ADDRESS 4  SCWA2PTR POINTER TO SCWA2
1504 (5E0) ADDRESS 4  SCWA3PTR Address of SCWA3
1508 (5E4) CHARACTER 4  SCWR5E4 Reserved
1512 (5E8) CHARACTER 8  SCWESRT0 Stop/Reset small area
1520 (5F0) CHARACTER 40  SCWESVR WORKAREA FOR SVC FLIH RECOVERY (IEAVESVR)
1560 (618) CHARACTER 72  SCWESVR1 SAVEAREA FOR SVC FLIH RECOVERY (IEAVESVR)
1632 (660) CHARACTER 72  SCWEGRSV SAVEAREA FOR GLOBAL RECOVERY (IEAVEGR)
1704 (6A8) CHARACTER 72  SCWVJST SAVEAREA PASSED TO VECTOR JOB STEP TIMING (IEAVVJST) BY JOB STEP TIMING (IEAVEJST)
1776 (6F0) CHARACTER 496  SCWVSLIH SAVEAREA FOR VECTOR SLIH (IEAVEVS)
2272 (8E0) CHARACTER 216  SCWESRT STOP/RESET SAVE AREA
2488 (9B8) CHARACTER 88  SCWEBBR WORK AREA FOR BIND BREAK (IEAVEBBR) INCLUDES AREA FOR EXCESSIVE SPIN ROUTINE PARAMETER LIST
2576 (A10) CHARACTER 200  SCWEES IPC/IEAVEES SAVE AREA
2776 (AD8) CHARACTER 72  SCWELSM GPR SAVE AREA USED WHEN CALLING LINKAGE STACK SERVICES
2848 (B20) CHARACTER 72  SCWELSL GPR SAVE AREA USED WHEN CALLING IEAVLSLC.
2920 (B68) CHARACTER 72  SCWXAPM GPR SAVE AREA USED BY IEAVEDS0 AND IEAVETCL WHEN CALLING IEAVXAPM.
2992 (BB0) CHARACTER 120  SCWESTA IEAVESTA WORK AREA
3112 (C28) CHARACTER 344  SCWESLK1 SUSPEND LOCK MANAGER WORK AREA
3456 (D80) CHARACTER 512  SCWELSIH WORK AREA FOR IEAVLSIH
3968 (F80) CHARACTER 8  SCWSGNL WORK AREA FOR STATUS SIGNAL ROUTINE
3976 (F88) CHARACTER 80  SCWESPN SAVE AREA FOR IEAVESPN. Also contains room for saving registers by invoker of SPINLOOP.
4056 (FD8) CHARACTER 8  SCWRFD8 RESERVED
    Moved not deleted
4064 (FE0) CHARACTER 0  SCWEND END OF SCWA
Table 2. Structure SCWA1
Offset
Dec
Offset
Hex
Type Len Name(Dim) Description
0 (0) STRUCTURE 4368 SCWA1 SCWA EXTENSION
0 (0) CHARACTER 400  SCW1LSWA WORK AREA FOR IEAVLSLO, IEAVLSLR, IEAVLSGO, IEAVLSGR, IEAVLSIO, IEAVLSIR.
400 (190) CHARACTER 256  SCW1LSLC WORK AREA FOR IEAVLSLC 1@LMD
656 (290) CHARACTER 16  SCW1ARPA SUPERVISOR ANALYSIS ROUTER PARAMETER AREA.
672 (2A0) CHARACTER 200  SCW1TTKN WORK AREA FOR IEAVTTKN 1@LMD
872 (368) CHARACTER 64  SCW1ELK5 IEAVELK RECURSIVE SAVE AREA.
936 (3A8) CHARACTER 160  SCW1ELKB WORKAREA FOR IEAVELKB
1096 (448) CHARACTER 144  SCW1ESPM SAVEAREA FOR SRB POOL MANAGER (IEAVESPM)
1240 (4D8) CHARACTER 384  SCW1SSWA WORK AREA FOR IEAVSRBR AND IEAVSRBP.
1624 (658) CHARACTER 256  SCW1ENTE Work Area for IEAVENTE
1880 (758) CHARACTER 512  SCW1AFS WORK AREA FOR IEAVEAFS AND IEAVASRB.
2392 (958) CHARACTER 40  SCW1CPUF WORK AREA FOR IEAVCPUF.
2432 (980) CHARACTER 72  SCW1EPC4 PROGRAM FLIH SAVE AREA
2504 (9C8) CHARACTER 192  SCW1R9C8 Reserved 1@LMD
2696 (A88) CHARACTER 640  SCW1SETS WORK AREA FOR IEAVSETS
3336 (D08) CHARACTER 72  SCW1SYSE SAVE AREA FOR USERRDY SYSEVENT
3408 (D50) CHARACTER 64  SCW1EPDR SAVE AREA FOR USE BY IEAVEPDR WHEN CALLING IEAVEDSR (was SCW2EPDR)
3472 (D90) CHARACTER 128  SCW1LSCL WORK AREA FOR IEAVLSCL
3600 (E10) CHARACTER 512  SCW1ELCR WORK AREA FOR IEAVELCR
4112 (1010) CHARACTER 256  SCW1ESAR WORK AREA FOR IEAVESAR.
4368 (1110) CHARACTER 0  SCW1END END OF SCWA1
Table 3. Structure SCWA2
Offset
Dec
Offset
Hex
Type Len Name(Dim) Description
0 (0) STRUCTURE 7184 SCWA2 SCWA EXTENSION.
0 (0) CHARACTER 72  SCW2WBCH SAVE AREA FOR IEAVWBCH
72 (48) CHARACTER 72  SCW2SRBX SAVE AREA FOR IEAMSRBX
144 (90) CHARACTER 72  SCW2ESC0 SAVE AREA FOR IEAVESC0
216 (D8) CHARACTER 256  SCW2ESPN WORK AREA FOR IEAVESPN. Must be same size as SCW3ESPN
472 (1D8) CHARACTER 72  SCW2ESLK SAVE AREA FOR IEAVESLK
544 (220) CHARACTER 256  SCW2WPM SAVE AREA FOR IEAVWPM
800 (320) CHARACTER 72  SCW2ESC5 SAVE AREA FOR IEAVESC5
872 (368) CHARACTER 896  SCW2SCHW WORK AREA FOR IEAVSCHA
1768 (6E8) CHARACTER 784  SCW2SRBM WORK AREA FOR IEAVSRBF AND IEAVSRBO.
         Moved and renamed, not deleted 1@LMD
2552 (9F8) CHARACTER 1096  SCW2EDSR WORK AREA FOR IEAVEDSR
3648 (E40) CHARACTER 464  SCW2CHAP WORK AREA FOR IEAVEAC0
4112 (1010) CHARACTER 3072  SCW2FPS WORK AREA FOR IEAVEFPS
7184 (1C10) CHARACTER 0  SCW2END END OF SCWA2
Table 4. Structure SCWA3
Offset
Dec
Offset
Hex
Type Len Name(Dim) Description
0 (0) STRUCTURE 1352 SCWA3 SCWA EXTENSION.
0 (0) CHARACTER 72  SCW3ESRT Work area for IEAVESRT
72 (48) CHARACTER 256  SCW3ESPN IEAVESPN re-entry. Must be same size as SCW2ESPN
328 (148) CHARACTER 256  SCW3ERI IEAVERI work area
584 (248) CHARACTER 768  SCW3ECPX IEAVECPX work area
1352 (548) CHARACTER 0  SCW3END END OF SCWA3
Table 5. Cross Reference for SCWA
Name Offset Hex Tag
SCWA 0
SCWASCWA 0
SCWA1 0
SCWA1PTR 5D8
SCWA2 0
SCWA2PTR 5DC
SCWA3 0
SCWA3PTR 5E0
SCWEBBR 9B8
SCWEDR 340
SCWEES A10
SCWEGR 4 10
SCWEGRSV 660
SCWEINT 3E0
SCWELKRF 4 40
SCWELK1 50
SCWELK2 98
SCWELK3 E0
SCWELK4 3A0
SCWELSIH D80
SCWELSL B20
SCWELSM AD8
SCWEND FE0
SCWEPC1 8
SCWEPC2 278
SCWEPC3 120
SCWERP 4B8
SCWESAR 1B0
SCWESAR2 1F8
SCWESLK1 C28
SCWESPN F88
SCWESRT 8E0
SCWESRT0 5E8
SCWESTA BB0
SCWESVR 5F0
SCWESVR1 618
SCWEXS 520
SCWFLAG 4
SCWFLAG1 4
SCWFRLK1 170
SCWLCRVT 4 20
SCWRFD8 FD8
SCWR5D8 5D0
SCWR5E4 5E4
SCWSARP 4 80
SCWSARWA 590
SCWSGNL F80
SCWSIGP 2C0
SCWUSRR 240
SCWVJST 6A8
SCWVQVPL 250
SCWVSLIH 6F0
SCWXAPM B68
SCW1AFS 758
SCW1ARPA 290
SCW1CPUF 958
SCW1ELCR E10
SCW1ELKB 3A8
SCW1ELK5 368
SCW1END 1110
SCW1ENTE 658
SCW1EPC4 980
SCW1EPDR D50
SCW1ESAR 1010
SCW1ESPM 448
SCW1LSCL D90
SCW1LSLC 190
SCW1LSWA 0
SCW1R9C8 9C8
SCW1SETS A88
SCW1SSWA 4D8
SCW1SYSE D08
SCW1TTKN 2A0
SCW2CHAP E40
SCW2EDSR 9F8
SCW2END 1C10
SCW2ESC0 90
SCW2ESC5 320
SCW2ESLK 1D8
SCW2ESPN D8
SCW2FPS 1010
SCW2SCHW 368
SCW2SRBM 6E8
SCW2SRBX 48
SCW2WBCH 0
SCW2WPM 220
SCW3ECPX 248
SCW3END 548
SCW3ERI 148
SCW3ESPN 48
SCW3ESRT 0