IRR8022 A related error occurred during database UPDATE processing. Utility processing has ended abnormally.

Explanation

An error occurred when accessing the coupling facility. IRRMIN00 PARM=UPDATE ran against an active data set while the system was in data sharing mode. The IRRMIN00 updates to DASD are complete, but the ICB is not updated in the coupling facility.

System action

IRRMIN00 processing ends abnormally.

System programmer response

Check the SYSPRINT. Also, check the information specified in message IRRX016I, which is issued to the system console.

You can do one of the following tasks:
  • Rerun the job from the original system if it is still in data sharing mode.
  • Rerun the job from another system in the RACF sysplex data sharing group, if that system is in data sharing mode.
  • Issue RVARY NODATASHARE to change the mode of all systems to non-data sharing mode, then rerun the job.