ODTE entry for outbound DLC timer events
- Entry:
- ODTE
- VIT option:
- CIA
- Event:
- OSA-Express® QDIO, Shared Memory Communications over Remote Direct Memory Access (SMC-R) processing, or HiperSockets timer
- VIT processing module:
- ISTITCOD
- Control is returned to
- ISTLLCWD, ISTLLCWT, ISTSRIWD, ISTSRIWT
This trace record is written when the OSA-Express QDIO, Shared Memory Communications over Remote Direct Memory Access (SMC-R), or HiperSockets write completion timer is started or restarted.
- Byte (hex)
- Contents
- 00–03
- Record ID: C"ODTE"
- 04
- ID is the primary address space ID (ASID). This field is 0 if the ASID is greater than X'FF'.
- 05
- Function:
- C"D" for dispatch of the timer task
- C"S" for start timer
- C"R" for restart timer
- 06-07
- STIMERM return code
- Code value
- Meaning
- X'0000'
- STIMERM service completed successfully.
- X'000C'
- Program error: Interval exceeds 2400 hours.
- X'0010'
- Program error: Parameters that are not valid are passed to STIMERM.
- X'001C'
- Program error: STIMERM SET limit for task exceeded.
- X'0024'
- Program error: STIMERM ID was not valid.
- X'0028'
- Program error: Interval plus TOD exceeds maximum clock comparator value.
- 08–0F
- Current Timer of Day (in TOD format)
- 10–17
- Interval or timer control information
- When Function is 'S' or 'R', the timer interval (in TOD format)
- When Function is 'D', the timer control fields for CDS processing
- 18–1B
- Module identifier for the module that issued the INTRACE
- 1C–1F
- NCB address
- If module identifier is 'LLWD' or 'LLWT', this is a DINCB address
- If module identifier is 'SRWD' or 'SRWT', this is an RUNCB address