Session exceptions
For exceptions that occurred during your OMEGAMON® for CICS® (3270) session, select the Exceptions this Session option (B) on the Exceptions path or enter fast path E.B from any panel.
An example of this panel is displayed in the following figure:
________________
ZEXTRP VTM VTM CICSSP31 V530./C SP22 11/23/13 15:51:03
> PF1 Help PF3 Back PF4 Main Menu PF7 Up PF8 Down PF11 Zoom
> A-Current Exceptions B-Exceptions this Session
=================================================================================
> SUMMARY OF EXCEPTIONS THIS SESSION
> For a recommendation, place the cursor on the exception name and press PF11.
TXTRP
+ Name Last Value Last Occurence Worst Value Worst Occurence
+ CPHI 77.33% 08/15 15:53:07 99.31% 08/15 4:12:07
+ ESIZ 384 08/15 15:53:07 384 08/15 5:53:07
+ GRSP 08/15 15:53:07 08/15 5:53:07
+ OSCH 1556K 08/15 15:53:07 1556K 08/15 5:53:07
+ RMTH 0% 08/15 15:53:07 0% 08/15 5:53:07
+ STRU 100% 08/15 15:52:24 100% 08/15 5:52:24
+ WSHI 2940K 08/15 15:53:07 3240K 08/15 5:33:41
=================================================================================
This screen provides a summary of all exceptions that occurred during this OMEGAMON for CICS (3270) session, displaying their worst value and their most recent value. The fields that compose the Exceptions Summary screen are:
- Name
- Four-character identifier for the exception. See CICS exceptions for a list of all possible exceptions.
- Last Value
- Value at the time the last exception occurred.
- Last Occurrence
- Date and time of the last occurrence.
- Worst Value
- Value of the worst occurrence during your session.
- Worst Occurrence
- Date and time of the worst occurrence.