DFHRP1543 date time applid tranid The CICS ONC RPC connection manager detected a logic error while accessing the CICS ONC RPC data set, CICS file filename, while registering 4-tuples from the data set.

Explanation

The connection manager has detected an error while accessing the CICS ONC RPC data set. This is a logic error since connection manager has received an unexpected response from CICS following an EXEC CICS STARTBR, EXEC CICS READNEXT or EXEC CICS ENDBR command.

The error occurred while processing a request to register 4-tuples from the data set. Associated message DFHRP1545 may have been issued to indicate the number of 4-tuples that were registered.

System action

A system dump is taken. The connection manager cannot register 4-tuples from the data set. Message DFHME0116, which contains the symptom string for this problem, is produced.

User response

You need further assistance from IBM to resolve this problem. See External Interfaces Guide and Working with IBM to solve your problem for guidance on how to proceed. Report the details of the symptom string given in message DFHME0116. It will aid problem determination.

Module

DFHRPC09

XMEOUT parameters/Message inserts

  1. date
  2. time
  3. applid
  4. tranid
  5. filename

Destination

CRPO

Applicable releases in Version 6

  • beta
  • 6.3
  • 6.2
  • 6.1