00F30406

Explanation

The Db2 subsystem was abended by module DSN3SSI1 because the system services address space was forced to an end-of-memory condition.

System action

The Db2 subsystem is terminated.with an SVC dump.

Operator response

You can start Db2 again after it terminates.

System programmer response

At least one SVC dump and associated SYS1.LOGREC entries should be available.

If you suspect an error in Db2, you might need to report the problem. For information about identifying and reporting the problem, see Collecting diagnostic data.

Problem determination

This is usually caused by a previous error that has recorded data on the SYS1.LOGREC data sets and requested an SVC dump. Examine the SYS1.LOGREC entries and SVC dumps to determine the actual cause of the error. Refer to Db2 abend completion codes (X'04E' and X'04F) for information on X'04F' and X'04E' abend completion codes.

Collect the following diagnostic items:
  • Console output from the system on which the job was run, and a listing of the SYSLOG data set for the period of time that spans the failure.
  • Dynamic dump, taken to SYS1.DUMPxx data set, by Db2 (04E and 04F abends).