RTE_X_KCNSTR00_PLEXCOLLECT
This parameter specifies whether or not the OMEGAMON subsystem address space may become the collector for this sysplex.
- Required or optional
- Optional
- Location where the parameter value is stored
- KCNSTR00 OMEGAMON subsystem startup member in the &rhilev.&rte.RKANPARU
library.
- Parameter name and syntax
PLEXCOLLECT=%RTE_X_KCNSTR00_PLEXCOLLECT%- Default value
YES- Permissible values
- YES, NO
- PARMGEN name
- RTE_X_KCNSTR00_PLEXCOLLECT
- Description
- This parameter specifies whether or not the OMEGAMON subsystem
address space may become the collector for this Sysplex. There are
two values:
- YES
- This OMEGAMON subsystem may become the Coupling Facility data collector for this sysplex. Only one OMEGAMON subsystem at a time is the collector, but OMEGAMON subsystems with this value may take over collection should the current collector fail or be terminated. YES is the default.
- NO
- This OMEGAMON subsystem may not become the collector for this sysplex. This OMEGAMON subsystem may initiate local collection if the sysplex collector cannot be located.
- Related parameters