QRadar xx29-C

The IBM® QRadar® xx29-C (MTM 4654-Q3A) supports various appliance types in your deployment.

The QRadar xx29-C appliance can be used for the following appliance types:

  • QRadar Event Processor 1629
  • QRadar Flow Processor 1729
  • QRadar Event and Flow Processor 1829
  • QRadar 3129 (All-in-One)
  • QRadar 3129 (Console)
  • QRadar Log Manager 1629
  • QRadar Log Manager 3129 (All-in-One)
  • QRadar Log Manager 3129 (Console)
  • QRadar App Host
  • QRadar 1400 Data Node

View hardware information and requirements for the QRadar xx29-C in the following table:

The following table describes hardware information and requirements for the QRadar xx29-C appliance:

Table 1. QRadar xx29-C specifications
Description Value
Maximum capacity

QRadar Event Processor 1629: 40,000 EPS

QRadar Flow Processor 1729: 2,400,000 FPM

QRadar Event and Flow Processor 1829: : 15,000 EPS, 300,000 FPM

QRadar 3129 (All-in-One): 15,000 EPS, 300,000 FPM

CPU 2 x Xeon Gold 5118 12C 2.3 GHz 16 MB Cache 3.20 GHz 105 W
Network management transceivers

2 x 10 GbE Short Range SFP+

The transceivers might have one of the following part numbers:
  • Avago AFBR-709SMZ-IB8
  • Finisar FTLX8571D3BCL-BN
  • BNT BN-CKM-SP-SR

Use these transceivers with the 2 x 10 GbE SFP+ ports, labeled as [3] in the appliance diagram.

Ports

2 x 16 Gbps Fibre Channel HBA ports

4 x 10/100/1000 Base-T Ethernet management ports

1 x RJ-45 10/100/1000 Mb Ethernet systems management (IMM) port

2 x 10 GbE SFP+ Ethernet management ports

Memory 128 GB, 8 x 16 GB 1866 MHz RDIMM
Storage 12 x 8 TB 7.2 K 12 Gbps 512e 3.5” NLSAS, 80 TB total (RAID6) 68 TB available to store event and flow data.
Power supply Dual redundant 1100 W AC
Unit weight 73 lbs
Physical dimensions 29.0 inches deep x 17.1 inches wide x 3.4 inches high

The following image is of the QRadar xx29-C appliance.

Figure 1. Front and rear panel of the QRadar xx29-C appliance
Image showing the back and front panels of the QRadar xx29-C appliance.

Picture: © 2018 Dell Inc. or its subsidiaries. All Rights Reserved

Table 2. Legend for use with the QRadar xx29-C image
Label Description
1 Event data storage
2 1 x RJ-45 10/100/1000 Mb Ethernet systems management (IMM) port
3 Management ports (10 GbE SFP+)
4 Management ports (1 GbE TX)
5 Fibre channel ports (16 Gb SFP+)

For information about battery replacement, see Dell EMC PowerEdge R740 Installation and Service Manual (https://topics-cdn.dell.com/pdf/poweredge-r740_owners-manual_en-us.pdf).