Use this information to help you map a location code to a position on the unit.
Note: The known logical location codes for this unit are listed next to the corresponding physical
location in the following information. If you are working with a logical location code for this unit
and it is not listed in the following information, contact your next level of support.
The following diagrams show the field replaceable unit (FRU) layout in the system. Use these diagrams with the following tables.



The following table provides location codes for parts that make up the storage enclosure.
| Failing item name | Physical location code | Identify LED | Failing item removal and replacement procedures |
|---|---|---|---|
| Storage enclosure | Un | Yes | |
| ESM | |||
| Enclosure Services Manager (ESM) A | Un-P1-C1 | Yes | See Removing and replacing an enclosure services manager in an ESLL or ESLS storage enclosure. |
| ESM B | Un-P1-C2 | Yes | |
| ESM A connector | Un-P1-C1-T1 |
Note: The connector in the Un-P1-C1-T1 location is not used.
|
|
| ESM A connector | Un-P1-C1-T2 | ||
| ESM A connector | Un-P1-C1-T3 | ||
| ESM B connector | Un-P1-C2-T1 |
Note: The connector in the Un-P1-C2-T1 location is not used.
|
|
| ESM B connector | Un-P1-C2-T2 | ||
| ESM B connector | Un-P1-C2-T3 | ||
| Power supplies | |||
| Power supply | Un-P1-E1 | Yes | See Removing and replacing a power supply in an ESLL or ESLS storage enclosure. |
| Power supply | Un-P1-E2 | Yes | |
| Midplane | |||
| Midplane | Un-P1 | See Removing and replacing a midplane in an ESLL or ESLS storage enclosure. | |
| ESLL and ESLS device physical locations | |||
| Disk drive 1 | Un-P1-D1 | Yes | See Removing and replacing disk drives or solid-state drives in an ESLL or ESLS storage enclosure. |
| Disk drive 2 | Un-P1-D2 | Yes | |
| Disk drive 3 | Un-P1-D3 | Yes | |
| Disk drive 4 | Un-P1-D4 | Yes | |
| Disk drive 5 | Un-P1-D5 | Yes | |
| Disk drive 6 | Un-P1-D6 | Yes | |
| Disk drive 7 | Un-P1-D7 | Yes | |
| Disk drive 8 | Un-P1-D8 | Yes | |
| Disk drive 9 | Un-P1-D9 | Yes | |
| Disk drive 10 | Un-P1-D10 | Yes | |
| Disk drive 11 | Un-P1-D11 | Yes | |
| Disk drive 12 | Un-P1-D12 | Yes | |
| ESLS device physical locations | |||
| Disk drive 13 | Un-P1-D13 | Yes | See Removing and replacing disk drives or solid-state drives in an ESLL or ESLS storage enclosure. |
| Disk drive 14 | Un-P1-D14 | Yes | |
| Disk drive 15 | Un-P1-D15 | Yes | |
| Disk drive 16 | Un-P1-D16 | Yes | |
| Disk drive 17 | Un-P1-D17 | Yes | |
| Disk drive 18 | Un-P1-D18 | Yes | |
| Disk drive 19 | Un-P1-D19 | Yes | |
| Disk drive 20 | Un-P1-D20 | Yes | |
| Disk drive 21 | Un-P1-D21 | Yes | |
| Disk drive 22 | Un-P1-D22 | Yes | |
| Disk drive 23 | Un-P1-D23 | Yes | |
| Disk drive 24 | Un-P1-D24 | Yes | |