ESLL or ESLS storage enclosure locations

Use this information to help you map a location code to a position on the unit.

Note: The known logical location codes for this unit are listed next to the corresponding physical location in the following information. If you are working with a logical location code for this unit and it is not listed in the following information, contact your next level of support.

The following diagrams show the field replaceable unit (FRU) layout in the system. Use these diagrams with the following tables.

Figure 1. Front view of the ESLL storage enclosure
Front view of the ESLL storage enclosure
Figure 2. Front view of the ESLS storage enclosure
Front view of the ESLS storage enclosure
Figure 3. Rear view of the ESLL or ESLS storage enclosure
Rear view of the ESLL or ESLS storage enclosure

The following table provides location codes for parts that make up the storage enclosure.

Table 1. FRU locations and failing components
Failing item name Physical location code Identify LED Failing item removal and replacement procedures
Storage enclosure Un Yes  
ESM
Enclosure Services Manager (ESM) A Un-P1-C1 Yes See Removing and replacing an enclosure services manager in an ESLL or ESLS storage enclosure.
ESM B Un-P1-C2 Yes
ESM A connector Un-P1-C1-T1  
Note: The connector in the Un-P1-C1-T1 location is not used.
ESM A connector Un-P1-C1-T2    
ESM A connector Un-P1-C1-T3    
ESM B connector Un-P1-C2-T1  
Note: The connector in the Un-P1-C2-T1 location is not used.
ESM B connector Un-P1-C2-T2    
ESM B connector Un-P1-C2-T3    
Power supplies
Power supply Un-P1-E1 Yes See Removing and replacing a power supply in an ESLL or ESLS storage enclosure.
Power supply Un-P1-E2 Yes
Midplane
Midplane Un-P1   See Removing and replacing a midplane in an ESLL or ESLS storage enclosure.
ESLL and ESLS device physical locations
Disk drive 1 Un-P1-D1 Yes See Removing and replacing disk drives or solid-state drives in an ESLL or ESLS storage enclosure.
Disk drive 2 Un-P1-D2 Yes
Disk drive 3 Un-P1-D3 Yes
Disk drive 4 Un-P1-D4 Yes
Disk drive 5 Un-P1-D5 Yes
Disk drive 6 Un-P1-D6 Yes
Disk drive 7 Un-P1-D7 Yes
Disk drive 8 Un-P1-D8 Yes
Disk drive 9 Un-P1-D9 Yes
Disk drive 10 Un-P1-D10 Yes
Disk drive 11 Un-P1-D11 Yes
Disk drive 12 Un-P1-D12 Yes
ESLS device physical locations
Disk drive 13 Un-P1-D13 Yes See Removing and replacing disk drives or solid-state drives in an ESLL or ESLS storage enclosure.
Disk drive 14 Un-P1-D14 Yes
Disk drive 15 Un-P1-D15 Yes
Disk drive 16 Un-P1-D16 Yes
Disk drive 17 Un-P1-D17 Yes
Disk drive 18 Un-P1-D18 Yes
Disk drive 19 Un-P1-D19 Yes
Disk drive 20 Un-P1-D20 Yes
Disk drive 21 Un-P1-D21 Yes
Disk drive 22 Un-P1-D22 Yes
Disk drive 23 Un-P1-D23 Yes
Disk drive 24 Un-P1-D24 Yes