5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S locations
Use this information to help you map a location code to a position on the
unit.
The following diagrams show field-replaceable unit (FRU) layouts in the system. Use these diagrams with the following tables.
Rack views
Note: The following graphics represent location codes for 5105-22E,
9008-22L, 9009-22A, 9009-22G,
9223-22H, or 9223-22S.





The following table provides location codes for parts that comprise the server.
| Failing item name | Physical location code | Identify LED | Failing item removal and replacement procedures |
|---|---|---|---|
| System unit | Un | ||
| Fans | |||
| Fan 1 | Un-A1 | Yes | See Fans. |
| Fan 2 | Un-A2 | Yes | |
| Fan 3 | Un-A3 | Yes | |
| Fan 4 | Un-A4 | Yes | |
| Power supplies | |||
| Power supply 1 | Un-E1 | Yes | See Power supplies. |
| Power supply 2 | Un-E2 | Yes | |
| Backplanes | |||
| System backplane | Un-P1 | Yes | See System backplane. |
| Drive backplane | Un-P2 | Yes | See Drive backplanes. |
| Ports | |||
| USB 3.0 port 1 (front) | Un-P1-T3 | No | See Cables. |
| USB 3.0 port 2 (front) | Un-P1-T4 | No | |
| USB 3.0 port 1 (rear) | Un-P1-T1 | No | |
| USB 3.0 port 2 (rear) | Un-P1-T2 | No | |
| USB 2.0 port 1 (rear) Note: This port is used only for firmware update and
uninterruptible power supply (UPS). This port is unavailable for host operating
systems.
|
Un-P1-C1-T3 | No | |
| USB 2.0 port 2 (rear) Note: This port is used only for firmware update and
uninterruptible power supply (UPS). This port is unavailable for host operating
systems.
|
Un-P1-C1-T4 | No | |
| Serial port | Un-P1-C1-T5 | No | |
| HMC port 1 | Un-P1-C1-T1 | No | |
| HMC port 2 | Un-P1-C1-T2 | No | |
| SAS cable port | Un-P1-C49-T1 | No | |
| Adapters | |||
| Service processor card | Un-P1-C1 | Yes | See Service processor card. |
| Time-of-day battery | Un-P1-C1-E1 | Yes | See Time-of-day battery. |
| PCIe4 x8 adapter | Un-P1-C2 | Yes | See Adapters. |
| PCIe4 x16 adapter (supports CAPI and PCIe cable adapters) | Un-P1-C3 | Yes | |
| PCIe4 x16 adapter (supports CAPI and PCIe cable adapters) | Un-P1-C4 | Yes | |
| PCIe4 x8 adapter (5105-22E, 9009-22G, or 9223-22S) | Un-P1-C5 | Yes | |
| PCIe4 x16 adapter (5105-22E, 9009-22G,
or 9223-22S) PCIe3 x8 adapter (9008-22L, 9009-22A, or 9223-22H) |
Un-P1-C6 | Yes | |
| PCIe4 x8 adapter (5105-22E, 9009-22G,
or 9223-22S) PCIe3 x8 adapter (9008-22L, 9009-22A, or 9223-22H) |
Un-P1-C7 | Yes | |
| PCIe4 x8 adapter (supports CAPI adapters) | Un-P1-C8 | Yes | See Adapters. |
| PCIe4 x16 adapter (supports CAPI and PCIe cable adapters) | Un-P1-C9 | Yes | |
| PCIe4 x8 adapter (5105-22E, 9009-22G, or 9223-22S) | Un-P1-C10 | Yes | |
| PCIe4 x8 adapter (5105-22E, 9009-22G,
or 9223-22S) PCIe3 x8 adapter (9008-22L, 9009-22A, or 9223-22H) |
Un-P1-C11 | Yes | |
| PCIe4 x16 adapter (5105-22E, 9009-22G,
or 9223-22S) PCIe3 x8 adapter (9008-22L, 9009-22A, or 9223-22H) |
Un-P1-C12 | Yes | |
| Vital product data card | Un-P1-C13 | Yes | See Vital product data card. |
| Trusted platform module card | Un-P1-C14 | No | See Trusted platform module card. |
| PCIe3 x8 SAS RAID internal adapter, PCIe3 x8 cache SAS RAID internal adapter, NVMe M.2 carrier card2, or NVMe U.2 pass-thru card3 | Un-P1-C49 | Yes | See one of the following procedures: |
| Backup power module card for the PCIe3 x8 cache SAS RAID internal adapter (see Figure 2) | Un-P1-C49-E1 | Yes | |
| NVMe M.2 flash module2 (see Figure 5) | Un-P1-C49-C1 | No | See NVMe M.2 carrier cards and flash modules. |
| NVMe M.2 flash module2 (see Figure 5) | Un-P1-C49-C2 | No | |
| PCIe3 x8 SAS RAID internal adapter, backup power module card for the PCIe3 x8 cache SAS RAID internal adapter, NVMe M.2 carrier card2, or NVMe U.2 pass-thru card3 | Un-P1-C50 | Yes | See one of the following procedures: |
| NVMe M.2 flash module2 (see Figure 5) | Un-P1-C50-C1 | No | See NVMe M.2 carrier cards and flash modules. |
| NVMe M.2 flash module2 (see Figure 5) | Un-P1-C50-C2 | No | |
| Memory modules | |||
| Memory module 1 | Un-P1-C15 | Yes | See Memory modules. |
| Memory module 2 | Un-P1-C16 | Yes | |
| Memory module 3 | Un-P1-C17 | Yes | |
| Memory module 4 | Un-P1-C18 | Yes | |
| Memory module 5 | Un-P1-C19 | Yes | |
| Memory module 6 | Un-P1-C20 | Yes | |
| Memory module 7 | Un-P1-C21 | Yes | |
| Memory module 8 | Un-P1-C22 | Yes | |
| Backup power module (BPM) cable for NVDIMM in location Un-P1-C224 | Un-P1-C22-T1 | No | See Removing and replacing BPM cables. |
| BPM for NVDIMM in location Un-P1-C224 | Un-P1-C22-T1-E1 | No | See Removing and replacing BPMs. |
| Memory module 91 | Un-P1-C23 | Yes | See Memory modules. |
| Memory module 101 | Un-P1-C24 | Yes | |
| Memory module 111 | Un-P1-C25 | Yes | |
| Memory module 121 | Un-P1-C26 | Yes | |
| Memory module 131 | Un-P1-C27 | Yes | |
| Memory module 141 | Un-P1-C28 | Yes | |
| Memory module 151 | Un-P1-C29 | Yes | |
| Memory module 161 | Un-P1-C30 | Yes | |
| Backup power module (BPM) cable for NVDIMM in location Un-P1-C304 | Un-P1-C30-T1 | No | See Removing and replacing BPM cables. |
| BPM for NVDIMM in location Un-P1-C304 | Un-P1-C30-T1-E1 | No | See Removing and replacing BPMs. |
| Memory module 17 | Un-P1-C31 | Yes | See Memory modules. |
| Memory module 18 | Un-P1-C32 | Yes | |
| Memory module 19 | Un-P1-C33 | Yes | |
| Memory module 20 | Un-P1-C34 | Yes | |
| Memory module 21 | Un-P1-C35 | Yes | |
| Memory module 22 | Un-P1-C36 | Yes | |
| Backup power module (BPM) cable for NVDIMM in location Un-P1-C364 | Un-P1-C36-T1 | No | See Removing and replacing BPM cables. |
| BPM for NVDIMM in location Un-P1-C364 | Un-P1-C36-T1-E1 | No | See Removing and replacing BPMs. |
| Memory module 23 | Un-P1-C37 | Yes | See Memory modules. |
| Memory module 24 | Un-P1-C38 | Yes | |
| Memory module 251 | Un-P1-C39 | Yes | |
| Memory module 261 | Un-P1-C40 | Yes | |
| Memory module 271 | Un-P1-C41 | Yes | |
| Memory module 281 | Un-P1-C42 | Yes | |
| Memory module 291 | Un-P1-C43 | Yes | |
| Memory module 301 | Un-P1-C44 | Yes | |
| Backup power module (BPM) cable for NVDIMM in location Un-P1-C444 | Un-P1-C44-T1 | No | See Removing and replacing BPM cables. |
| BPM for NVDIMM in location Un-P1-C444 | Un-P1-C44-T1-E1 | No | See Removing and replacing BPMs. |
| Memory module 311 | Un-P1-C45 | Yes | See Memory modules. |
| Memory module 321 | Un-P1-C46 | Yes | |
| Processor and processor regulator | |||
| System processor module 1 | Un-P1-C47 | Yes | See System processor module. |
| System processor module 21 | Un-P1-C48 | Yes | |
| Disk drives or solid-state drives | |||
| Drive 1 | Un-P2-D1 | Yes | See Disk drives or solid-state drives. |
| Drive 2 | Un-P2-D2 | Yes | |
| Drive 3 | Un-P2-D3 | Yes | |
| Drive 4 | Un-P2-D4 | Yes | |
| Drive 5 | Un-P2-D5 | Yes | |
| Drive 6 | Un-P2-D6 | Yes | |
| Drive 7 (internal) | Un-P2-D7 | Yes | |
| Drive 8 (internal) | Un-P2-D8 | Yes | |
| NVMe U.2 drives | |||
| NVMe U.2 drive 13 | Un-P2-C1 | Yes | See NVMe U.2 drives. |
| NVMe U.2 drive 23 | Un-P2-C2 | Yes | |
| NVMe U.2 drive 33 | Un-P2-C3 | Yes | |
| NVMe U.2 drive 43 | Un-P2-C4 | Yes | |
| Control panel | |||
| Control panel | Un-D1 | Yes | See Control panel and control panel display. |
| Control panel display | Un-D2 | Yes | |
|
1 Not applicable for systems that have only one system processor module. 2 Supported only on the 9008-22L, 9009-22A, or 9223-22H system. 3 Supported only on the 9009-22G or 9223-22S system. 4 Supported only on the 5105-22E system. |
|||