5147-024, ESLL, and ESLS storage enclosures

Hardware specifications for 5147-024, ESLL, and ESLS storage enclosures provide detailed information for your storage enclosures, including dimensions, electrical, power, temperature, environment, and service clearances.

Table 1. Dimensions for storage enclosures
Width Depth Height Weight (maximum configuration)
448.6 mm (17.7 in.) 744.22 mm (29.3 in.) 87.4 mm (3.4 in.) 37.1 kg (81.8 lb) (ESLL)
31.1 kg (68.6 lb) (5147-024 or ESLS)
Table 2. Electrical characteristics
Electrical characteristics Properties
AC rated voltage and frequency 100 - 127 V ac or 200 - 240 V ac at 50 or 60 Hz plus or minus 3 Hz
Thermal output (maximum) 939 BTU/hr
Maximum power consumption 275 W
Maximum kVA 0.28
Phase Single
Table 3. Environment requirements
Environment Recommended operating Allowable operating Nonoperating
ASHRAE class   A3  
Airflow direction   Front-to-back  
Temperature1 18°C - 27°C (64°F - 80°F) 5°C - 40°C (41°F - 104°F) 1°C - 60°C (34°F - 140°F)
Humidity range 5.5°C (42°F) dew point (DP) to 60% relative humidity (RH) and 15°C (59°F) dew point -12.0°C (10.4°F) DP and 8% - 80% RH 5% - 80% RH
Maximum dew point   24°C (75°F) 27°C (80°F) 
Maximum operating altitude   3050 m (10000 ft)  
Shipping temperature     -40°C to 60°C (-40°F to 140°F)
Shipping relative humidity     5% - 100%
  1. Derate maximum allowable dry-bulb temperature 1°C per 175 m above 950 m.
Table 4. Service clearances for rack-mounted expansion unit
Front Back Sides
914 mm (36 in.) 914 mm (36 in.) 914 mm (36 in.)
Side and top clearances are optional during operation.

Safety compliance: This hardware is designed and certified to meet the following safety standards: UL 60950; CAN/CSA C22.2 No. 60950–00; EN 60950; IEC 60950 including all National Differences.