POWER7 information

5802 expansion unit

Hardware specifications provide detailed information for your expansion unit, including dimensions, electrical, power, temperature, environment, and service clearances.

Table 1. Dimensions for rack-mounted expansion unit
Maximum configuration weight Width Depth Height
54 kg (120 lb) 444.5 mm (17.5 in.) 711.2 mm (28 in.) 4U
Table 2. Electrical
Electrical characteristics Properties
kVA (maximum) .768 kVA
Rated voltage and frequency   100 - 127 V ac or 200 - 240 V ac at 50 - 60Hz
Thermal output (maximum) 2542 BTU/hr
Power requirements (maximum)  745 W
Power factor   .97
Leakage current (maximum)  3.5 mA
Phase Single
Plug type (Canada and U.S.) 26
Power cord length 14 ft
Table 3. Temperature requirements
Operating Storage Shipping
10°C - 38°C (32°F - 100.4°F) 1°C - 60°C (33.8°F - 140°F) -40°C to 60°C (-40°F to 140°F)
Table 4. Environment requirements
Properties Operating Nonoperating Storage Shipping Maximum altitude
Noncondensing humidity   Recommended: 34% - 54%

Allowable: 20% - 80%

5% - 80% 5% - 80% 5% - 100% 3048 m (10 000 ft)
Table 5. Noise emissions
Models Properties Operating Idle
Feature Code 5802 - 4U I/O drawer consists of 18 SSF disk drives, 10 PCI-Express 8x slots, and 2 DCAs LWAd (B) 7.0 7.0
LpAm (dB) 52 52
Notes:
  1. LWAd is the statistical upper-limit A-weighted sound power level (rounded to the nearest 0.1 B).
  2. LpAm is the mean A-weighted emission sound pressure level measured at the 1-meter bystander positions (rounded to the nearest dB).
  3. 10 dB (decibel) = 1 B (bel).
  4. All measurements made in conformance with ISO 7779 and declared in conformance with ISO 9296.
Table 6. Service clearances
Front Back Sides
915 mm (36 in.) 915 mm (36 in.) 914 mm (36 in.)


Send feedback Rate this page

Last updated: Thu, March 15, 2018