| System characteristics | Properties |
|---|---|
| Product type | Computer server |
| Year first manufactured | 2010 |
| Power characteristics | Properties |
|---|---|
| Internal/external power supply efficiency | 80 PLUS Verification and Testing Report |
| Maximum power (watts) | 1630 W |
| Idle state power (watts) | 501 W |
| Sleep mode power (watts) | N/A for servers |
| Off mode power (watts) | 26 W |
| Product description | Declared A-weighted sound pressure level, LpAm (dB) | |
|---|---|---|
| Operating | Idle | |
| 8205-E6D 2 socket processor, 2 power supplies, and IBM® rack | 44 | 43 |
| 8205-E6D 2 socket processor, 2 power supplies, IBM rack, and low-profile PCIe riser card | 42 | 42 |
| 8205-E6D 2 socket processor, 2 power supplies, 8 hard drives, IBM rack, and acoustic mode off | 48 | 48 |
| d 8205-E6D 2 socket processor, 2 power supplies, 8 hard drives, IBM rack, acoustic mode off, and low-profile PCI riser card | 50 | 50 |
| 8205-E6D 2 socket processor, 1 power supply, rack-integrated configuration, and low-profile PCI riser card | 52 | 52 |
| 8205-E6D 2 socket processor, 8 hard drives, 2 power supplies, IBM rack, acoustic mode off, low-profile PCI riser card, and rack acoustical doors FC 6248 or 6249. | 42 | 42 |
| Test parameters | Properties |
|---|---|
| Test voltage and frequency | 230 V ac at 50 Hz or 60 Hz |
| Total harmonic distortion of the electricity supply system | The maximum harmonic content of the input voltage waveform is equal to or less than 2%. The qualification is compliant with EN 61000-3-2. |
| Information and documentation on the instrumentation setup and circuits that are used for electrical testing | ENERGY STAR Test Method for Computer Servers; ECOVA Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies |
| Measurement methodology that is used to determine information in this document | ENERGY STAR Servers Version 2.0 Program Requirements; ECOVA Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies |