POWER7 information

Power 720 Express (Machine Type: 8202) Technical Documentation for EU Regulation 617/2013

International Business Machines Corporation
New Orchard Road
Armonk, New York 10504
http://www.ibm.com/customersupport/

For more information, see http://www-03.ibm.com/systems/power/hardware/energy-star/.

Table 1. System characteristics
System characteristics Properties
Product type Computer server
Year first manufactured 2011
Table 2. Power characteristics
Power characteristics Properties
Internal/external power supply efficiency 80 PLUS Verification and Testing Report
Maximum power (watts) 995 W
Idle state power (watts) 229 W
Sleep mode power (watts) N/A for servers
Off mode power (watts) 25 W
Table 3. Noise levels (Declared A-weighted sound pressure level, LpAm)
Product description Declared A-weighted sound pressure level, LpAm (dB)
  Operating Idle
8202-E4D single-socket processor, rack-integrated configuration, two power supplies, and six hard disk drives. 40 38
8202-E4D single-socket processor, two power supplies, six hard disk drives, and stand-alone system feature code (7572) 39 37
8202-E4D single-socket processor, rack-integrated configuration, two power supplies, low profile PCIe riser card, and six hard disk drives 47 47
8202-E4D single-socket processor, rack-integrated configuration, two power supplies, six hard disk drives, and acoustic mode off. 49 49
8202-E4D single-socket processor, rack-integrated configuration, one power supply, and six hard disk drives 51 51
8202-E4D single-socket processor, rack-integrated configuration, one power supply, six hard disk drives, and low profile PCIe riser card. 52 52
Table 4. Test parameters for measurements
Test parameters Properties
Test voltage and frequency 230 V ac at 50 Hz or 60 Hz
Total harmonic distortion of the electricity supply system The maximum harmonic content of the input voltage waveform is equal to or less than 2%. The qualification is compliant with EN 61000-3-2.
Information and documentation on the instrumentation setup and circuits that are used for electrical testing ENERGY STAR Test Method for Computer Servers; ECOVA Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies
Measurement methodology that is used to determine information in this document ENERGY STAR Servers Version 2.0 Program Requirements; ECOVA Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies


Send feedback Rate this page

Last updated: Thu, March 15, 2018