subscribe iconSubscribe to this information
POWER7 information

SIP4147

Use this procedure to resolve the following problem: Missing remote adapter (SRC xxxx9076)

An adapter attached in a dual storage IOA configuration was not discovered in the allotted time. Determine which one of the following items is the cause of your specific error and take the appropriate actions listed. If this action does not correct the error, contact your hardware service provider. The possible causes are:
  • An attached adapter for the configuration is not installed or is not powered on. Some adapters are required to be part of a Dual Storage IOA Configuration. Ensure that both adapters are properly installed and powered on.
  • If this configuration is a dual storage IOA configuration, then both adapters might not be in the same partition. Ensure that both adapters are assigned to the same partition.
  • The 175 MB cache RAID and dual storage IOA enablement card is not seated properly. See SAS RAID enablement and cache battery pack for the model 8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, or 8205-E6D for information about removing and installing the card.
    Attention: Appropriate service procedures must be followed when reseating the 175 MB cache RAID and dual storage IOA enablement card because removal of this card can cause data loss if incorrectly performed.
  • An attached adapter for the configuration failed. Take action on the other errors that have occurred at the same time as this error.
  • Adapter code levels are not up to date or are not at the same level of supported function. Ensure that the code for both adapters is at the latest level.
Note: The adapter that is logging this error will run in a performance degraded mode, without caching, until the problem is resolved.
This ends the procedure.


Send feedback Rate this page

Last updated: Thu, July 23, 2015