Use this procedure to resolve the following problem: Multiple adapters not capable of controlling the same set of devices (SRC xxxx9074)
Perform the following steps:
In order to interpret the hexadecimal information to get device addresses. See More information from hexadecimal reports . The Problem description field indicates the type of problem. The type, serial number, and Worldwide ID of the connected adapter is also available.
| Problem description | Full description | Action | Adapter on which to perform the action |
|---|---|---|---|
| Secondary is unable to find devices found by the primary. | Secondary adapter cannot discover all the devices that the primary has. | Verify the connections to the devices from the
adapter that logged the error. See SAS fabric identification to verify connections. |
Adapter that logged the error. |
| Secondary found devices not found by the primary. | Secondary adapter has discovered more devices than the primary. After this error is logged, an automatic failover will occur. | Verify the connections to the devices from the
remote adapter as indicated in the error log. See SAS fabric identification to verify connections. |
Remote adapter indicated in the error log. |
| Primary lost contact with disk units accessible by secondary. | Link failure from primary adapter to devices. An automatic failover will occur. | Verify the connections to the devices from the
adapter that logged the error. See SAS fabric identification to verify connections. |
Adapter that logged the error. |
| Other | Not currently defined. | Contact your hardware service provider. |