POWER7 information

SIADPCD

The failing component is the I/O bridge card or a 12X adapter card in an I/O unit.

Use the following table to determine the part number for the field replaceable unit (FRU).

CCIN or FFC Type and model Part number Description Location code
50A2 5802, 5877 See System parts. I/O backplane Un-P1
50A2 5803, 5873 See System parts. I/O backplane Un-P1, Un-P2
520C 5796, 7314-G30 See System parts. I/O backplane Un-P1
520A or 520B 5796, 7314-G30 See System parts. Riser Un-P1-C7

If you need additional information for failing part numbers, location codes, or removal and replacement procedures, see Part locations and location codes. Select your machine type and model number to find additional location codes, part numbers, or replacement procedures for your system.



Send feedback Rate this page