POWER7 information
I2CBUS
A fault was detected on the I2C bus.
If you need additional information for failing part numbers, location codes, or removal and replacement procedures, see Part locations and location codes. Select your machine type and model number to find additional location codes, part numbers, or replacement procedures for your system.
- Is the reference code of the form 1xxx314x?
- Yes: Continue with the next step.
- No: Use the following table to determine the FRU to replace.
If there are multiple FRUs listed in one row, replace those FRUs one
at a time in the order shown.This ends the procedure.
Reference code Type and model or feature code Part number Description Location code 3100, 3105 8248-L4T, 8408-E8D, 8412-EAD, 9109-RMD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, 9179-MHD See System parts Primary service processor card Un-P1-C1 3100, 3101, 3118, 310A, or 310B 5796, 7314-G30 See System parts - SPCN card
- I/O backplane
- Dual-port 12X Channel Attach adapter
- Un-P1-C8
- Un-P1
- Un-P1-C7
3102, 3103, 3104, 3114, 3121, 3122, 3123, 3124 5796, 7314-G30 See System parts - I/O backplane
- SPCN card
- Dual-port 12X Channel Attach adapter
- Un-P1
- Un-P1-C8
- Un-P1-C7
3105, 3125 5796, 7314-G30 See System parts - Dual-port 12X Channel Attach adapter
- I/O backplane
- SPCN card
- Un-P1-C7
- Un-P1
- Un-P1-C8
3106, 3115 5796, 7314-G30 See System parts - Power supply
- SPCN card
- I/O backplane
- Un-E1
- Un-P1-C8
- Un-P1
3114, 3116 8233-E8B, 8236-E8C See System parts System backplane Un-P1 3114 8248-L4T, 8408-E8D, 8412-EAD, 9109-RMD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, 9179-MHD See System parts - I/O backplane
- Primary service processor card
- Un-P2
- Un-P1-C1
- Is the reference code 1xxx3140?
- No: Continue with the next step.
- Yes: Replace the midplane in the 5802 expansion unit at location Un-P5. This ends the procedure.
- Is the reference code 1xxx3141?
- No: Continue with the next step.
- Yes: If this is your first time here, replace the SAS conduit card in the 5802 expansion unit at location Un-P5. If this is your second time here, replace the midplane in the 5802 expansion unit at location Un-P5. This ends the procedure.
- Is the reference code 1xxx3142?
- No: Continue with the next step.
- Yes: If this is your first time here, replace the disk drive backplane in the 5802 expansion unit at location Un-P3. If this is your second time here, replace the SAS conduit card in the 5802 expansion unit at location Un-P4. This ends the procedure.
- Is the reference code 1xxx3143?
- No: Continue with the next step.
- Yes: If this is your first time here, replace the I/O backplane in the 5802 expansion unit at location Un-P1. If this is your second time here, replace the midplane in the 5802 expansion unit at location Un-P5. This ends the procedure.
- Is the reference code 1xxx3145?
- No: Continue with the next step.
- Yes: Replace the midplane in the 5802 expansion unit at location Un-P5. This ends the procedure.
- Is the reference code 1xxx3146?
- No: Continue with the next step.
- Yes: Replace the fan in the 5802 expansion unit at location Un-E1-A1. If this is your second time here, replace the midplane in the 5802 expansion unit at location Un-P5. This ends the procedure.
- Is the reference code 1xxx3147?
- No: Continue with the next step.
- Yes: Replace the fan in the 5802 expansion unit at location Un-E1-A2. If this is your second time here, replace the midplane in the 5802 expansion unit at location Un-P5. This ends the procedure.
- Is the reference code 1xxx3148?
- No: Continue with the next step.
- Yes: Replace port card 1 in the 5802 expansion unit at
location Un-P3-C1. If this is your second time
here, replace these parts in the 5802 expansion
unit in the following order:
- Midplane at location Un-P5.
- SAS conduit at location Un-P4.
- Disk drive backplane at location Un-P3.
- Is the reference code 1xxx3149?
- No: Continue with the next step.
- Yes: Replace port card 2 in the 5802 expansion unit at
location Un-P3-C2. If this is your second time
here, replace these parts in the 5802 expansion
unit in the following order:
- Midplane at location Un-P5.
- SAS conduit at location Un-P4.
- Disk drive backplane at location Un-P3.
- Is the reference code 1xxx314A?
- No: Continue with the next step.
- Yes: Replace port card 3 in the 5802 expansion unit at
location Un-P3-C3. If this is your second time
here, replace these parts in the 5802 expansion
unit in the following order:
- Midplane at location Un-P5.
- SAS conduit at location Un-P4.
- Disk drive backplane at location Un-P3.
- Is the reference code 1xxx314B?
- No: Continue with the next step.
- Yes: Replace port card 4 in the 5802 expansion unit at
location Un-P3-C4. If this is your second time
here, replace these parts in the 5802 expansion
unit in the following order:
- Midplane at location Un-P5.
- SAS conduit at location Un-P4.
- Disk drive backplane at location Un-P3.
- Is the reference code 1xxx3155?
- No: Continue with the next step.
- Yes: If this is your first time here, replace the midplane in the 5802 expansion unit at location Un-P5. This ends the procedure.
- Is the reference code 1xxx3156?
- No: Continue with the next step.
- Yes: If this is your first time here, replace the fan in the 5802 expansion unit at location Un-E2-A1. If this is your second time here, replace the midplane in the 5802 expansion unit at location Un-P5. This ends the procedure.
- Is the reference code 1xxx3157?
- No: Return to the procedure or symbolic FRU that sent you here.
- Yes: If this is your first time here, replace the fan in the 5802 expansion unit at location Un-E2-A2. If this is your second time here, replace the midplane in the 5802 expansion unit at location Un-P5. This ends the procedure.