POWER7 information

FWVTHMC

Look here for information about FWVTHMC symbolic FRU.

If you received symbolic FRU FWVTHMC, perform the following procedure:

  1. The partition firmware is waiting for a virtual terminal to be opened on the management console. Open a virtual terminal.
  2. If a virtual terminal is open, the user might have entered a CTRL-S key sequence to stop the scrolling of data off the screen. If this is the case, enter a CTRL-Q key sequence to resume scrolling.
  3. Check the Ethernet connection between the management console and the managed system.
  4. Reboot the management console.
  5. There might be a hardware problem with the management console. For the Hardware Management Console (HMC), see Hardware Management Console models 7042-CR4, 7042-C06, and 7042-C07 service. For the IBM® Systems Director Management Console (SDMC), see Systems Director Management Console service.
  6. There might be a hardware problem with the service processor in the managed system. Check the service action event log for error codes that indicate a problem with the Ethernet ports on the service processor. Take the appropriate actions based on the error codes that you find.

This ends the procedure.



Send feedback Rate this page

Last updated: Fri, May 18, 2018