Hardware specifications provide detailed information for
your expansion unit, including dimensions, electrical, power, temperature,
environment, and service clearances.
Pictured is the PCI-X expansion unit.
Table 1. Dimensions for 5095 expansion unit | Dimensions |
Width |
Depth (with 30 mm (1.2 in.) front cover
and 100 mm (3.9 in.) rear cover) |
Height |
| Metric |
217 mm |
818 mm |
555 mm |
| English |
8.5 in. |
32.2 in. |
21.9 in. |
Table 2. Dimensions for 0595 expansion
unit | Dimensions |
Width |
Depth |
Height |
Height in 0551 rack2, 4 |
| Metric |
430 mm |
658 mm |
217 mm |
5 EIA |
| English |
16.9 in. |
25.9 in. |
8.5 in. |
5 U |
Table 3. Electrical| Electrical characteristics |
Properties |
| Maximum configuration weight |
52.7 kg (116 lb) |
| kVA (maximum) |
0.358 |
| Rated voltage and frequency |
100 - 127 or 200 - 240 V ac
at 50 - 60 plus or minus 0.5 Hz |
| Thermal output (maximum) |
1161 Btu/hr |
| Power requirements (maximum) |
340 W |
| Power factor |
0.95 |
| Inrush current |
60 A |
| Leakage current (maximum) |
3.5 mA |
| Redundant power and cooling |
1 |
Table 4. Temperature
requirements| Operating |
Nonoperating |
| 10 - 38°C (50 - 100.4 °F) |
1 - 60 C (33.8 - 140 °F) |
Table 5. Environment requirements| Properties |
Operating |
Nonoperating |
| Noncondensing humidity |
8 - 80% |
8 - 80% |
| Wet bulb temperature |
23°C (73.4°F) |
27°C (80.6°F) |
Table 6. Maximum altitude| 3048 m (10 000 ft) |
Table 7. Noise emissions1| Properties |
Operating |
Idle |
| LWAd |
6.2 bels |
6.1 bels |
| LpAm (1-meter bystander) |
44 dB |
43 dB |
Table 8. Service clearances| Front |
Back |
Sides3 |
Top3 |
| 762 mm |
762 mm |
762 mm |
762 mm |
| 30 in. |
30 in. |
30 in. |
30 in. |
Table 9. NotesNotes:
- For a description of noise emission values, see Acoustics.
- Feature code 0595 is
a PCI-X expansion unit in a rack.
- Side and top clearances are optional when operating.
- See 0551 rack configurations for typical configurations