SIIOADP

The RIO adapter/HSL I/O bridge might be failing.

Note: In the following procedures, the term RIO adapter refers to either a RIO adapter or an HSL I/O bridge, depending on the server to which it applies.

  1. Is a location for this FRU given in the serviceable event view?
    • Yes: Use that location and Table 6 to find and replace the failing part. This ends the procedure.
    • No: Continue with the next step. Note: In most circumstances, the SRC logged by the system firmware calls out a FRU list. In very few circumstances (as in the following examples), the failure requires immediate system termination.

      Example: Symptoms

      1  B7006981  RIO/HSL/12X (bridge) bus adapter failure SRC
      2  XXXXXX62  SRC Format 62
      3  00010002  Component ID field must be an exact match
      4  14993203  Code Model and PRC must be an exact match
      5  FRUCALLO  Decode this when the SRC is 6906 or 6907
      6  FRUCALLO  Decode this when the SRC is 6981
      7  00000000
      Example: SRC 6981
      1 B7006981
      2 00000062
      3 00010002
      4 14993203
      6 00044000
      7 00000000
      When immediate termination occurs, the SRC does not provide a FRU callout. The following steps describe how to determine the FRU callout.
  2. Isolate the RIO adapter FRU indicated by the data in word 5 (when the SRC is 6906 or 6907) or word 6 (when the SRC is 6981) of the SRC by completing the following steps:

    Note: Replace only the FRU with the RIO/HSL adapter FRU.

    1. Use the following example as a guide to locate and record the following binary values from word 5 or word 6 of the SRC:
      • RIO hub ID
      • RIO port pair ID
      • RIO loop position

      Example: Decoding FRU Callout 00044000

      Figure 1. Decoding FRU Callout 00044000
    2. Convert the binary values for the RIO hub ID, the RIO port pair ID, and the RIO loop position to decimal. Record these values for later use.
  3. Each RIO hub controls two RIO loops, specified as the first and second loop. Use the following list to determine and record which of these two RIO loops is indicated in word 6 of the SRC:
    • When the binary value of the RIO port pair ID is 0000, the SRC indicates the first RIO loop
    • When the binary value of the RIO port pair ID is 0001, the SRC indicates the second RIO loop
  4. To isolate the failing RIO adapter, you will walk the cabling for the specified RIO loop from the leading port to the trailing port. To determine the RIO loop number and RIO port location code for the leading port, perform the following steps:
    1. Make sure you have the following values at hand, then continue with the next step.
      • The decimal value for the RIO hub ID
      • The RIO loop indicated by the RIO port pair ID
    2. Compare the values from the previous step to the location tables for your server below. Record the values for the RIO loop number and the RIO port location code. Then continue with the next step.

      Loop location information for 8203-E4A, 8261-E4S, 9407-M15, 9408-M25

      Table 1. 8203-E4A, 8261-E4S, 9407-M15, 9408-M25 SIIOADP RIO loop location information
      Hub (decimal) Loop number (hex / dec) Location code for leading port of the loop
      1 0686/1670 Un-P1-C8-T2
      1 0781/1921 Un-P1-C8-T2
      2 0688/1672 Un-P1-C6-T2
      2 0782/1922 Un-P1-C6-T2

      Loop location information for 8204-E8A, 9409-M50

      Table 2. 8204-E8A, 9409-M50 SIIOADP RIO loop location information
      Hub (decimal) Loop number (hex / dec) Location code for leading port of the loop
      1 0686/1670 Un-P1-C8-T2
      1 0781/1921 Un-P1-C8-T2
      2 0688/1672 Un-P1-C7-T2
      2 0782/1922 Un-P1-C7-T2

      Loop location information for 9117-MMA and 9406-MMA

      Table 3. 9117-MMA, 9406-MMA SIIOADP RIO loop location information
      System unit drawer Hub (decimal) Loop number (hex / dec) Location code for leading port of the loop
      0 1 0686/1670 Un-P1-C8-T2
      0 1 0781/1921 Un-P1-C8-T2
      0 2 0688/1672 Un-P1-C9-T2
      0 2 0782/1922 Un-P1-C9-T2
      1 9 0696/1686 Un-P1-C8-T2
      1 9 0789/1929 Un-P1-C8-T2
      1 10 078A/1930 Un-P1-C9-T2
      1 10 0698/1688 Un-P1-C9-T2
      2 17 06A6/1702 Un-P1-C8-T2
      2 17 0791/1937 Un-P1-C8-T2
      2 18 06A8/1704 Un-P1-C9-T2
      2 18 0792/1938 Un-P1-C9-T2
      3 25 06B6/1718 Un-P1-C8-T2
      3 25 0799/1945 Un-P1-C8-T2
      3 26 06B8/1720 Un-P1-C9-T2
      3 26 079A/1946 Un-P1-C9-T2

      Loop location information for 9119-FHA

      Table 4. 9119-FHA SIIOADP RIO loop location information
      Hub (decimal) Loop number (hex / dec) Loop type Location code for leading port of the loop
      0 0684/1668 RIO Un-P9-C39-T2
      0 0780/1920 12X Un-P9-C39-T2
      1 0686/1670 RIO Un-P7-C39-T2
      1 0781/1921 12X Un-P7-C39-T2
      2 0688/1672 RIO Un-P9-C40-T2
      2 0782/1922 12X Un-P9-C40-T2
      3 068A/1674 RIO Un-P7-C40-T2
      3 0783/1923 12X Un-P7-C40-T2
      4 068C/1676 RIO Un-P9-C38-T2
      4 0784/1924 12X Un-P9-C38-T2
      5 068E/1678 RIO Un-P7-C38-T2
      5 0785/1925 12X Un-P7-C38-T2
      6 0690/1680 RIO Un-P9-C37-T2
      6 0786/1926 12X Un-P9-C37-T2
      7 0692/1682 RIO Un-P7-C37-T2
      7 0787/1927 12X Un-P7-C37-T2
      8 0694/1684 RIO Un-P5-C39-T2
      8 0788/1928 12X Un-P5-C39-T2
      9 0696/1686 RIO Un-P8-C39-T2
      9 0789/1929 12X Un-P8-C39-T2
      10 0698/1688 RIO Un-P5-C40-T2
      10 078A/1930 12X Un-P5-C40-T2
      11 069A/1690 RIO Un-P8-C40-T2
      11 078B/1931 12X Un-P8-C40-T2
      12 069C/1692 RIO Un-P5-C38-T2
      12 078C/1932 12X Un-P5-C38-T2
      13 069E/1694 RIO Un-P8-C38-T2
      13 078D/1933 12X Un-P8-C38-T2
      14 06A0/1696 RIO Un-P5-C37-T2
      14 078E/1934 12X Un-P5-C37-T2
      15 06A2/1698 RIO Un-P8-C37-T2
      15 078F/1935 12X Un-P8-C37-T2
      16 06A4/1700 RIO Un-P6-C39-T2
      16 0790/1936 12X Un-P6-C39-T2
      17 06A6/1702 RIO Un-P3-C39-T2
      17 0791/1937 12X Un-P3-C39-T2
      18 06A8/1704 RIO Un-P6-C40-T2
      18 0792/1938 12X Un-P6-C40-T2
      19 06AA/1706 RIO Un-P3-C40-T2
      19 0793/1939 12X Un-P3-C40-T2
      20 06AC/1708 RIO Un-P6-C38-T2
      20 0794/1940 12X Un-P6-C38-T2
      21 06AE/1710 RIO Un-P3-C38-T2
      21 0795/1941 12X Un-P3-C38-T2
      22 06B0/1712 RIO Un-P6-C37-T2
      22 0796/1942 12X Un-P6-C37-T2
      23 06B2/1714 RIO Un-P3-C37-T2
      23 0797/1943 12X Un-P3-C37-T2
      24 06B4/1716 RIO Un-P2-C39-T2
      24 0798/1944 12X Un-P2-C39-T2
      25 06B6/1718 RIO Un-P4-C39-T2
      25 0799/1945 12X Un-P4-C39-T2
      26 06B8/1720 RIO Un-P2-C40-T2
      26 079A/1946 12X Un-P2-C40-T2
      27 06BA/1722 RIO Un-P4-C40-T2
      27 079B/1947 12X Un-P4-C40-T2
      28 06BC/1724 RIO Un-P2-C38-T2
      28 079C/1948 12X Un-P2-C38-T2
      29 06BE/1726 RIO Un-P4-C38-T2
      29 079D/1949 12X Un-P4-C38-T2
      30 06C0/1728 RIO Un-P2-C37-T2
      30 079E/1950 12X Un-P2-C37-T2
      31 06C2/1730 RIO Un-P4-C37-T2
      31 079F/1951 12X Un-P4-C37-T2

      Loop location information for 9125-F2A

      Table 5. 9125-F2A SIIOADP RIO loop location information
      Hub (decimal) Loop number (hex / dec) Loop type Location code for leading port of the loop
      2 0782/1922 12X Un-P2-C65-T2
      8 0788/1928 12X Un-P2-C65-T4
      12 069C/1692 RIO Un-P1-internal
      16 0790/1936 12X Un-P2-C66-T2
      20 06AC/1708 RIO Un-P1-internal
      21 0795/1941 12X Un-P1-T2
      30 079E/1950 12X Un-P2-C66-T4
  5. Isolate the failing RIO adapter by walking the cabling for the specified RIO loop from the leading port to the trailing port. Complete the following steps:
    1. Begin walking the cabling by starting at the RIO loop number and RIO port location code that you recorded in step 4.b.
    2. Starting with 0 (zero) for the first RIO adapter on the loop, follow the loop cabling and count each RIO adapter in the order it is cabled. For example, the first RIO adapter is 0, the next is 1, the next is 2, and so on.
    3. Continue this process until you count up to the decimal value of the RIO loop position. The RIO adapter that corresponds to the value of the RIO loop position is the failing RIO adapter.
    Note: Concurrent maintenance requires that you make a change to the previous procedure for counting the RIO adapters on the loop. If concurrent maintenance was performed to attach one or more additional RIO adapters to this loop and the server has not performed an IPL after the adapters were added, exclude the added RIO adapters as you make the initial count. If the RIO loop position exceeds the number of RIO adapters, continue by counting the added RIO adapters in the order they were added to the loop.
  6. Replace the failing RIO adapter. To determine the FRU part number and the FRU location, use the following table to find and replace the failing part. This ends the procedure.
Table 6. SIIOADP FRU part numbers
CCIN or FFC Type and model Part number Description Location code
  1519 42R4468 Integrated xSeries® adapter (IXA)  
2886 0595, 5095, 7311-D20 39J0669 RIO/HSL (optical) adapter card Un-P1-C05
2887 0595, 5095, 7311-D20 39J0527 RIO/HSL adapter card Un-P1-C05
28E7 0595, 5095, 7311-D20 39J0523 RIO/HSL-2 adapter card Un-P1-C05
2886 5094, 5096, 5294, 5296 39J0669 HSL (optical) I/O bridge adapter Un-CB1-C10
2887 5094, 5096, 5294, 5296 39J0527 HSL I/O bridge adapter Un-CB1-C10
28E7 5094, 5096, 5294, 5296 39J0523 HSL-2 I/O bridge adapter Un-CB1-C10
28FF 5790, 7311-D11 03N5633 RIO/HSL-2 adapter card Un-P1-C7
520A 5796, 7314-G30 10N8782 Riser Un-P1-C7
520B 5796, 7314-G30 See Finding parts, locations, and addresses. Riser Un-P1-C7
520C 5796, 7314-G30 See Finding parts, locations, and addresses. I/O backplane Un-P1
50A2 5802, 5877 See Finding parts, locations, and addresses. I/O backplane Un-P1
50AA 5802, 5877 See Finding parts, locations, and addresses. Midplane Un-P5
50A2 5803, 5873 See Finding parts, locations, and addresses. I/O backplane Un-P1, Un-P2
50A8 5803, 5873 See Finding parts, locations, and addresses. Midplane Un-P5
1814 8203-E4A, 8261-E4S See Finding parts, locations, and addresses. GX+ RIO adapter Un-P1-C6, Un-P1-C8
1817 8203-E4A, 8261-E4S See Finding parts, locations, and addresses. GX+ 12X adapter Un-P1-C6, Un-P1-C8
52B4 8203-E4A, 8261-E4S See Finding parts, locations, and addresses. GX++ 12X adapter Un-P1-C6
1802 8203-E4A, 8261-E4S, 9407-M15, 9408-M25 10N9982 RIO-2/HSL-2 adapter card Un-P1-Cx
1814 8204-E8A See Finding parts, locations, and addresses. RIO adapter Un-P1-C7, Un-P1-C8
1817 8204-E8A See Finding parts, locations, and addresses. GX+ 12X adapter Un-P1-C7, Un-P1-C8
52B4 8204-E8A See Finding parts, locations, and addresses. GX++ 12X adapter Un-P1-C7
1802 8204-E8A, 9409-M50 10N6859 RIO-2/HSL-2 adapter card Un-P1-Cx
1800 9406-MMA, 9117-MMA 39J0792 RIO-2/HSL-2 adapter card Un-P1-Cx
293B 9406-MMA,9117-MMA 42R7352 I/O backplane Un-P1
2BA0 9119-FHA See Finding parts, locations, and addresses. System backplane Un-P1
295A 9119-FHA See Finding parts, locations, and addresses. RIO/HSL Un-Px-C37, Un-Px-C38, Un-Px-C39, Un-Px-C40
295B 9119-FHA See Finding parts, locations, and addresses. GX++ 12X adapter Un-Px-C37, Un-Px-C38, Un-Px-C39, Un-Px-C40
296E 9125-F2A See Finding parts, locations, and addresses. System backplane Un-P1
182E 9125-F2A See Finding parts, locations, and addresses. GX adapter Un-P2-C65, Un-P2-C66