Look here for information about PGDPART symbolic FRU.
Use the following tables to determine the part number for the field replaceable unit (FRU).
8203-E4A, 8261-E4S, 9407-M15, 9408-M25
| CCIN or FFC | Type and model | Part number | Description | Location code |
| 8203-E4A, 8261-E4S, 9407-M15, 9408-M25 | See System parts. | System backplane | Un-P1 | |
| 8203-E4A, 8261-E4S, 9407-M15, 9408-M25 | 44V4195 | Power supplies, ac | Un-Ex | |
| 8203-E4A, 8261-E4S, 9407-M15, 9408-M25 | See System parts. | Memory card | Un-P1-Cx |
8204-E8A, 9409-M50
| CCIN or FFC | Type and model | Part number | Description | Location code |
| 8204-E8A, 9409-M50 | 10N9369 | System backplane | Un-P1 | |
| 8204-E8A, 9409-M50 | 44V3559 | Power supplies, ac | Un-Ex | |
| 8204-E8A, 9409-M50 | 42R6607 | Power supplies, dc | Un-Ex | |
| 4520 | 8204-E8A, 9409-M50 | 77P6497 | 512 MB DDR2 memory card | Un-P1-Cx-Cy |
| 4521 | 8204-E8A, 9409-M50 | 77P6498 | 1 GB DDR2 memory card | Un-P1-Cx-Cy |
| 4522 | 8204-E8A, 9409-M50 | 77P6499 | 2 GB DDR2 memory card | Un-P1-Cx-Cy |
| 4523 | 8204-E8A, 9409-M50 | 77P6500 | 4 GB DDR2 memory card | Un-P1-Cx-Cy |
| 4524 | 8204-E8A, 9409-M50 | 87H3621 | 8 GB DDR2 memory card | Un-P1-Cx-Cy |
| 2947 | 8204-E8A, 9409-M50 | 77P7504 | 16 GB DDR2 memory card | Un-P1-Cx-Cy |
| 8204-E8A, 9409-M50 | 10N9377 | 4.2 GHz POWER6®, 2-core processor card | Un-P1-Cx | |
| 8204-E8A, 9409-M50 | 10N9380 | 4.7 GHz POWER6, 2-core processor card | Un-P1-Cx |
9406-MMA, 9117-MMA
| CCIN or FFC | Type and model | Part number | Description | Location code |
| 9406-MMA, 9117-MMA | 10N8752 | Service processor card (the SPCN function is built into the service processor card for this system) | Un-P1-C11 | |
| 9406-MMA, 9117-MMA | See System parts. | Power supplies | Un-Ex | |
| 319B | 9406-MMA, 9117-MMA | 15R7433 | 512 MB DDR2 memory card | Un-P2-Cx-Cy |
| 319C | 9406-MMA, 9117-MMA | 15R7436 | 1 GB DDR2 memory card | Un-P2-Cx-Cy |
| 319E | 9406-MMA, 9117-MMA | 15R7439 | 2 GB DDR2 memory card | Un-P2-Cx-Cy |
| 319D | 9406-MMA, 9117-MMA | 15R7445 | 4 GB DDR2 memory card | Un-P2-Cx-Cy |
| 319F | 9406-MMA, 9117-MMA | 15R7448 | 8 GB DDR2 memory card | Un-P2-Cx-Cy |
| 9406-MMA, 9117-MMA | 10N9146 | 3.5 GHz POWER6, 2-core processor card | Un-P2-Cx | |
| 9406-MMA, 9117-MMA | 10N9144 | 4.2 GHz POWER6, 2-core processor card | Un-P2-Cx | |
| 9406-MMA, 9117-MMA | 10N9139 | 4.7 GHz POWER6, 2-core processor card | Un-P2-Cx | |
| 9406-MMA, 9117-MMA | 42R7352 | I/O Backplane | Un-P1 | |
| 9406-MMA, 9117-MMA | 10N8550 | System processor backplane | Un-P2 |
5790, 7311-D11
| CCIN or FFC | Type and model | Part number | Description | Location code |
| 5790, 7311-D11 | 22R3958 | Power supplies | Un-Ex | |
| 5790, 7311-D11 | 80P6626 | I/O drawer backplane | Un-P1 |
0595, 5095, 7311-D20
| CCIN or FFC | Type and model | Part number | Description | Location code |
| 0595, 5095, 7311-D20 | 39J2781 | Power supplies | Un-Ex | |
| 0595, 5095, 7311-D20 | 39J0515 | I/O drawer backplane | Un-P1 |
5796, 7314-G30
| CCIN or FFC | Type and model | Part number | Description | Location code |
| 5796, 7314-G30 | 10N8867 | SPCN Card | Un-P1-C8 | |
| 5796, 7314-G30 | 42R4491 | Power supplies | Un-Ex | |
| 5796, 7314-G30 | See System parts. | I/O drawer backplane | Un-P1 |
Use the following tables to determine the part number for the field replaceable unit (FRU).
9406-MMA, 9117-MMA
| CCIN or FFC | Type and model | Part number | Description | Location code |
| 9406-MMA, 9117-MMA | 10N8752 | Service processor card (the SPCN function is built into the service processor card for this system) | Un-P1-C11 | |
| 9406-MMA, 9117-MMA | 42R8325 | Voltage regulators | Un-P2-Cx (where x is equal to 3, 4, or 5) | |
| 9406-MMA, 9117-MMA | 42R7352 | I/O Backplane | Un-P1 |
5790, 7311-D11
| CCIN or FFC | Type and model | Part number | Description | Location code |
| 5790, 7311-D11 | 22R3958 | Power supplies | Un-Ex | |
| 5790, 7311-D11 | 80P6626 | I/O drawer backplane | Un-P1 |
0595, 5095, 7311-D20
| CCIN or FFC | Type and model | Part number | Description | Location code |
| 0595, 5095, 7311-D20 | 39J2781 | Power supplies | Un-Ex | |
| 0595, 5095, 7311-D20 | 39J0515 | I/O drawer backplane | Un-P1 |
5796, 7314-G30
| CCIN or FFC | Type and model | Part number | Description | Location code |
| 5796, 7314-G30 | 42R4491 | Power supplies | Un-Ex | |
| 5796, 7314-G30 | 10N8867 | SPCN Card | Un-P1-C8 | |
| 5796, 7314-G30 | See System parts. | I/O drawer backplane | Un-P1 |
Use the following tables to determine the part number for the field replaceable unit (FRU).
8203-E4A, 8261-E4S, 9407-M15, 9408-M25
| CCIN or FFC | Type and model | Part number | Description | Location code |
| 8203-E4A, 8261-E4S, 9407-M15, 9408-M25 | See System parts. | System backplane (the service processor is part of the sytem backplane for this server) | Un-P1 | |
| 8203-E4A, 8261-E4S, 9407-M15, 9408-M25 | 44V4195 | Power supplies, ac | Un-Ex |
8204-E8A, 9409-M50
| CCIN or FFC | Type and model | Part number | Description | Location code |
| 8204-E8A, 9409-M50 | 10N9369 | System backplane (the service processor is part of the sytem backplane for this server) | Un-P1 | |
| 8204-E8A, 9409-M50 | 44V3559 | Power supplies, ac | Un-Ex | |
| 8204-E8A, 9409-M50 | 42R6607 | Power supplies, dc | Un-Ex |
9406-MMA, 9117-MMA
| CCIN or FFC | Type and model | Part number | Description | Location code |
| 9406-MMA, 9117-MMA | 10N8752 | Service processor card (the SPCN function is built into the service processor card for this server) | Un-P1-C11 | |
| 9406-MMA, 9117-MMA | See System parts. | Power supplies | Un-Ex | |
| 9406-MMA, 9117-MMA | 42R7352 | I/O Backplane | Un-P1 |
5790, 7311-D11
| CCIN or FFC | Type and model | Part number | Description | Location code |
| 5790, 7311-D11 | 22R3958 | Power supplies | Un-Ex | |
| 5790, 7311-D11 | 80P6626 | I/O drawer backplane | Un-P1 |
0595, 5095, 7311-D20
| CCIN or FFC | Type and model | Part number | Description | Location code |
| 0595, 5095, 7311-D20 | 39J2781 | Power supplies | Un-Ex | |
| 0595, 5095, 7311-D20 | 39J0515 | I/O drawer backplane | Un-P1 |
5796, 7314-G30
| CCIN or FFC | Type and model | Part number | Description | Location code |
| 5796, 7314-G30 | 10N8867 | SPCN Card | Un-P1-C8 | |
| 5796, 7314-G30 | 42R4491 | Power supplies | Un-Ex | |
| 5796, 7314-G30 | See System parts. | I/O drawer backplane | Un-P1 |