Look here for information about FWPCI1 symbolic FRU.
Perform one of the following options:
- If the location code identifies a slot:
- Check for adapter firmware updates. Apply the update if one is
available.
- Replace the adapter. See Managing
PCI adapters for PCI
adapter FRU part numbers.
- Check for platform firmware updates. Apply the update if one is
available.
- If the location code identifies an I/O backplane:
- Check for platform firmware updates. Apply the update if one is
available.
- Replace the I/O backplane (system backplane on certain systems).
Use the following table to determine the part number for the field
replaceable unit (FRU).
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
8203-E4A, 8261-E4S, 9407-M15, 9408-M25 |
See System parts. |
System backplane |
Un-P1 |
| |
8204-E8A, 9409-M50 |
10N9369 |
System backplane |
Un-P1 |
| |
9406-MMA, 9117-MMA |
42R7352 |
I/O backplane |
Un-P1 |
| |
5790, 7311-D11 |
80P6626 |
I/O backplane |
Un-P1 |
| |
0595, 5095, 7311-D20 |
39J0515 |
I/O backplane |
Un-P1 |
| |
5796, 7314-G30 |
See System parts. |
I/O backplane |
Un-P1 |
| |
5094, 5096, 5294, 5296 |
39J3058 |
I/O backplane |
Un-CB1 |
- Call service support.
This ends the procedure.