FI01107 indicates that any storage device attached to the
I/O (SCSI) bus of this IOP might be the failing item.
Complete the following steps:
- Find the IOP address. See the System
reference code format description.
- To determine the location of the I/O processor card, see Part locations and location codes.
The
unit reference code indicates the I/O (SCSI) bus that has the problem:
- URC 3020, 3100 -- I/O bus 0
- URC 3021, 3101 -- I/O bus 1
- URC 3022, 3102 -- I/O bus 2
- URC 3023, 3103 -- I/O bus 3
- Any other URC -- Any I/O bus on the I/O card
- See Part locations and location codes to
find the diagram of the system unit or the expansion unit and perform
the following:
- Find the IOP card location identified by the direct select address.
- Find all the storage devices on the same I/O (SCSI)
bus.
- Replace the failing device. Use the device type to determine the
part.
- If the reference code that called out this failing item does not
have a problem analysis procedure, perform the IOPIP16 procedure to isolate
the possible failing device.