There is an Ethernet communications failure on one of the BPCs or a fault on one of the BPCs.
Complete the following steps:
For 575 (9125-F2A):
Ensure all HubA (T5) Ethernet cables on the service processors are routed to the same BPA on one side of the system and HubB (T6) cables are routed to the other BPA. If a problem is found, correct it. This ends the procedure.For 595 (9119-FHA):
Ensure that the following Ethernet connections are cabled correctly:
- On the SC (system controller) at Un-P1-C2: ent0 is connected to J05 on BPH-A, and ent1 is connected to J05 on BPH-B. If a problem is found, correct it. This ends the procedure.
- On the SC (system controller) at Un-P1-C5: ent0 is connected to J06 on BPH-A, and ent1 is connected to J06 on BPH-B. If a problem is found, correct it. This ends the procedure.
Communications problems result if cabling is mixed during repair or installation.
If the Ethernet cabling is correct, continue to the next item in the FRU list. This ends the procedure.
| SRC | Replace this FRU | Locations information |
|---|---|---|
| 1xxx8740 | BPC A (front) | Part locations and location codes |
| 1xxx8741 | BPC B (rear) |
This ends the procedure.